- Computers & electronics
- Networking
- Network switches
- TKH Security Solutions
- XSNet S4104 SW
- User manual
Switch Management. TKH Security Solutions XSNet S4104 SW (EOL), XSNet S4104 SW
Add to My manuals205 Pages
advertisement
XSNet S4104SW/S4108SW
Switch Management
This chapter explains the methods that you can use to configure management access to the switch. It describes the types of management applications and the communication and management protocols that deliver data between your management device (workstation or personal computer) and the system. It also contains information about port connection options.
This chapter covers the following topics:
•
Management Access Overview
•
Key Concepts
•
Key Guidelines for Implementation
•
Web Management Access
•
Administration Console Access
•
SNMP Access
•
Standards, Protocols, and Related Reading
Management Access Overview
The switch gives you the flexibility to access and manage the switch using any or all of the following methods.
The web browser interface and administration console (CLI) support are embedded in the switch software and are available for immediate use.
21
XSNet S4104SW/S4108SW
Administration Console (CLI)
The administration console is an internal, character-oriented,
Command Line Interface (CLI) for performing system administration such as displaying statistics or changing option settings.
Using this method, you can view the administration console from a terminal, personal computer, Apple Macintosh, or workstation connected to the switch’s console port.
Direct Access
Direct access to the administration console is achieved by directly connecting a terminal or a PC equipped with a terminal-emulation program (such as HyperTerminal) to the switch console port.
When using the management method, configure the terminal-emulation program to use the following parameters (you can change these settings after login):
[DEFAULT PARAMETERS]
115,200bps
8 data bits
parity
1 stop bit
This management method is often preferred because you can remain connected and monitor the system during system reboots. Also, certain error messages are sent to the serial port, regardless of the interface through which the associated action was initiated. A Macintosh or PC attachment can use any terminal-emulation program for connecting to the terminal serial port. A workstation attachment under UNIX can use an emulator such as TIP.
22
XSNet S4104SW/S4108SW
Web Management
The switch provides a browser interface that lets you configure and manage the switch remotely.
After you set up your IP address for the switch, you can access the switch’s web interface applications directly in your web browser by entering the IP address of the switch. You can then use your web browser to list and manage switch configuration parameters from one central location, just as if you were directly connected to the switch’s console port.
SNMP-Based Network Management
You can use an external SNMP-based application to configure and manage the switch. This management method requires the SNMP agent on the switch and the SNMP
Network Management Station to use the same community string. This management method, in fact, uses two community strings: the get community string and the set community string. If the SNMP Network management station only knows the set community string, it can read and write to the MIBs. However, if it only knows the get community string, it can only read MIBs.
The default get and set community strings for the switch are public.
23
XSNet S4104SW/S4108SW
Protocols
The switch supports the following protocols:
VIRTUAL TERMINAL PROTOCOLS, SUCH AS TELNET
A virtual terminal protocol is a software program, such as Telnet, that allows you to establish a management session from a Macintosh, a PC, or a UNIX workstation. Because Telnet runs over TCP/IP, you must have at least one IP address configured on the switch before you can establish access to it with a virtual terminal protocol.
<Note> Terminal emulation is different from a virtual terminal protocol in that you must connect a terminal directly to the console port.
SIMPLE NETWORK MANAGEMENT PROTOCOL (SNMP)
SNMP is the standard management protocol for multivendor IP networks.
SNMP supports transaction-based queries that allow the protocol to format messages and to transmit information between reporting devices and data-collection programs. SNMP runs on top of the User Datagram Protocol
(UDP), offering a connectionless-mode service.
Management Architecture
All of the management application modules use the same
Messaging Application Programming Interface (MAPI). By unifying management methods with a single MAPI, configuration parameters set using one method (e.g. console port) are immediately displayed the other management methods (e.g. SNMP agent of web browser).
The management architecture of the switch adheres to the
IEEE open standard. This compliance assures customers that the switch is compatible with, and will interoperate with other solutions that adhere to the same open standard.
24
advertisement
Related manuals
advertisement
Table of contents
- 1 Manual
- 1 Quick Start Guide
- 1 Physical Description
- 1 The Port Status LEDs and Power Inputs
- 2 Functional Description
- 3 Console Configuration
- 5 Web Configuration
- 7 Preface
- 8 Table of Contents
- 10 Product Overview
- 10 Industrial Managed Ethernet Switch
- 10 Package Contents
- 11 Product Highlights
- 11 Basic Features
- 11 Management Support
- 11 VLAN
- 11 TRUNKING
- 11 PORT-SECURITY
- 11 PORT-MIRRORING
- 12 QOS (IEEE802.1p Quality of Service)
- 12 INTERNETWORKING PROTOCOLS
- 12 NETWORK MANAGEMENT METHODS
- 13 Front Panel Display
- 13 This LED comes on when the switch is properly connected to power and turned on.
- 13 The LEDs are located on the front panel, displaying status for each respective port. Please refer to the following table for more details.
- 14 Physical Ports
- 14 CONNECTIVITY
- 14 MODE SELECTION
- 15 Switch Management
- 15 Web-based browser interface
- 15 Administration console via RS-232 serial port (CLI)
- 15 External SNMP-based network management application
- 16 Installation
- 16 Selecting a Site for the Switch
- 17 Connecting to Power
- 17 12VDC DC Jack
- 17 Redundant DC Terminal Block Power Inputs
- 17 Alarms for Power Failure
- 18 Connecting to Your Network
- 18 Cable Type & Length
- 20 Cabling
- 21 Switch Management
- 21 Management Access Overview
- 22 Administration Console (CLI)
- 22 Direct Access
- 22 [DEFAULT PARAMETERS]
- 23 Web Management
- 23 SNMP-Based Network Management
- 24 Protocols
- 24 VIRTUAL TERMINAL PROTOCOLS, SUCH AS TELNET
- 24 A virtual terminal protocol is a software program, such as Telnet, that allows you to establish a management session from a Macintosh, a PC, or a UNIX workstation. Because Telnet runs over TCP/IP, you must have at least one IP address configured on the switch before you can establish access to it with a virtual terminal protocol.
- 24 SIMPLE NETWORK MANAGEMENT PROTOCOL (SNMP)
- 24 SNMP is the standard management protocol for multivendor IP networks. SNMP supports transaction-based queries that allow the protocol to format messages and to transmit information between reporting devices and data-collection programs. SNMP runs on top of the User Datagram Protocol (UDP), offering a connectionless-mode service.
- 24 Management Architecture
- 25 SNMP & RMON Management
- 25 Overview
- 25 - The RMON probe is an intelligent device or software agent that continually collects statistics about a LAN segment or VLAN. The RMON probe transfers the collected data to a management workstation on request or when a pre-defined threshold is reached.
- 25 - The management workstation collects the statistics that the RMON probe gathers. The workstation can reside on the same network as the probe, or it can have an in-band or out-of-band connection to the probe.
- 26 SNMP Agent and MIB-2 (RFC 1213)
- 26 - Retrieving MIB counters from various layers of software modules according to the SNMP GET/GET NEXT frame messages.
- 26 - Setting MIB variables according to the SNMP SET frame message.
- 26 - Generating an SNMP TRAP frame message to the Network Management Station if the threshold of a certain MIB counter is reached or if other trap conditions (such as the following) are met:
- 26 WARM START
- 26 COLD START
- 26 LINK UP
- 26 LINK DOWN
- 26 AUTHENTICATION FAILURE
- 26 RISING ALARM
- 26 FALLING ALARM
- 26 TOPOLOGY ALARM
- 26 RMON MIB (RFC 2819) and Bridge MIB (RFC 1493)
- 27 RMON Groups Supported
- 27 - RMON Statistics Group – maintains utilization and error statistics for the switch port being monitored.
- 27 - RMON History Group – gathers and stores periodic statistical samples from the previous Statistics Group.
- 27 - RMON Alarm Group – allows a network administrator to define alarm thresholds for any MIB variable. An alarm can be associated with Low Threshold, High Threshold, or both. A trigger can trigger an alarm when the value of a specific MIB variable exceeds a threshold, falls below a threshold, or exceeds or falls below a threshold.
- 27 - RMON Event Group – allows a network administrator to define actions based on alarms. SNMP Traps are generated when RMON Alarms are triggered. The action taken in the Network Management Station depends on the specific network management application.
- 27 Bridge Groups Supported
- 27 - The dot1dBase Group – a mandatory group that contains the objects applicable to all types of bridges.
- 27 - The dot1dStp Group – contains objects that denote the bridge’s state with respect to the Spanning Tree Protocol. If a node does not implement the Spanning Tree Protocol, this group will not be implemented. This group is applicable to any transparent only, source route, or SRT bridge that implements the Spanning Tree Protocol.
- 27 - The dot1dTp Group – contains objects that describe the entity’s transparent bridging status. This group is applicable to transparent operation only and SRT bridges.
- 27 - The dot1dStatic Group – contains objects that describe the entity’s destination-address filtering status. This group is applicable to any type of bridge which performs destination-address filtering.
- 28 Web-Based Browser Management
- 28 Logging on to the switch
- 28 SWITCH IP ADDRESS
- 29 LOGIN
- 29 Enter the factory default login ID: root.
- 29 PASSWORD
- 29 Enter the factory default password (no password).
- 30 Understanding the Browser Interface
- 30 SYSTEM
- 30 System Information, System Name/Password, IP Address, ARP Table, Route Table, Save Configuration, Firmware Upgrade, Alarm Setting, Reboot, Logout
- 30 PORT
- 30 Configuration, Port Status, Rate Control, RMON Statistics, Per Port Vlan Activities, Port Security
- 30 SWITCHING
- 30 Bridging, Static MAC Entry, Port Mirroring
- 31 TRUNKING
- 31 Port Trunking, LACP Trunking
- 31 STP / RING
- 31 VLAN
- 31 VLAN Mode Setting, 802.1Q VLAN Setting, 802.1Q Port Setting, Port Based VLAN
- 31 QOS
- 31 Global Configuration, 802.1p Priority, DSCP
- 31 SNMP
- 31 802.1X
- 31 OTHER PROTOCOLS
- 32 System
- 32 System Information
- 36 ARP Table
- 37 Route Table
- 44 Alarm Setting
- 47 Port
- 53 Switching
- 56 Trunking
- 58 STP / Ring
- 68 Chain Setting
- 69 VLAN
- 76 QoS
- 79 SNMP
- 84 802.1x
- 87 Port Authentication
- 88 Other Protocols
- 97 Command Line Console Management
- 97 Administration Console
- 98 Exec Mode (View Mode)
- 102 Privileged Exec Mode (Enable Mode)
- 107 Configure Mode (Configure Terminal Mode)
- 111 User Interface Configuration
- 111 Http Server, Http Secure-Server, Telnet, SSH
- 113 System
- 113 System Information, System Name/Password, IP Address, ARP Table, Route Table, Save Configuration, Firmware Upgrade, Alarm Setting, Reboot, Logout
- 124 Port
- 124 Configuration, Port Status, Rate Control, RMON Statistics, Per Port Vlan Activities, Port Security
- 131 Switching
- 131 Bridging, Static MAC Entry, Port Mirroring
- 136 Trunking
- 136 Port Trunking, LACP Trunking
- 141 STP / Ring
- 141 Global Configuration, RSTP Port Setting, MSTP Properties, MSTP Instance Setting, MSTP Port Setting, Ring Setting, Chain Setting
- 155 Chain Setting
- 157 VLAN
- 157 VLAN Mode Setting, 802.1Q VLAN Setting, 802.1Q Port Setting, Port Based VLAN
- 163 QoS
- 166 SNMP
- 173 802.1x
- 178 Other Protocols
- 196 Specifications
- 196 LED Indicators
- 196 Operating
- 196 Temperature
- 198 Appendix A
- 199 Appendix B