1 Intended Audience. Omron Sysmac CS/CJ Series DeviceNet Units


Add to my manuals
292 Pages

advertisement

1 Intended Audience. Omron Sysmac CS/CJ Series DeviceNet Units | Manualzz

Intended Audience

1

1

Intended Audience

This manual is intended for the following personnel, who must also have knowledge of electrical systems (an electrical engineer or the equivalent).

• Personnel in charge of installing FA systems.

• Personnel in charge of designing FA systems.

• Personnel in charge of managing FA systems and facilities.

2 General Precautions

The user must operate the product according to the performance specifications described in the operation manuals.

Before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems, machines, and equipment that may have a serious influence on lives and property if used improperly, consult your OMRON representative.

Make sure that the ratings and performance characteristics of the product are sufficient for the systems, machines, and equipment, and be sure to provide the systems, machines, and equipment with double safety mechanisms.

This manual provides information for installing and operating the DeviceNet

Unit. Be sure to read this manual before operation and keep this manual close at hand for reference during operation.

3

!WARNING

It is extremely important that a PLC and all PLC Units be used for the specified purpose and under the specified conditions, especially in applications that can directly or indirectly affect human life. You must consult with your OMRON representative before applying a PLC System to the above mentioned applications.

Safety Precautions

!WARNING

Never attempt to disassemble a Unit or touch the inside of Unit while power is being supplied. Doing so may result in serious electrical shock or electrocution.

!WARNING

Provide safety measures in external circuits, i.e., not in the Programmable

Controller (CPU Unit including associated Units; referred to as “PLC”), in order to ensure safety in the system if an abnormality occurs due to malfunction of the PLC or another external factor affecting the PLC operation. Not doing so may result in serious accidents.

• Emergency stop circuits, interlock circuits, limit circuits, and similar safety measures must be provided in external control circuits.

• The PLC will turn OFF all outputs when its self-diagnosis function detects any error or when a severe failure alarm (FALS) instruction is executed.

As a countermeasure for such errors, external safety measures must be provided to ensure safety in the system.

• The PLC outputs may remain ON or OFF due to deposition or burning of the output relays or destruction of the output transistors. As a counter-

xvi

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Key Features

  • Support for both explicit and implicit messaging
  • Extensive diagnostics and error handling capabilities
  • Flexible addressing options
  • Baud rate up to 500 kbps
  • Supports up to 64 nodes per network
  • Rugged construction for harsh industrial environments
  • Easy-to-use design for quick and easy setup

Related manuals

Frequently Answers and Questions

What are the dimensions of the CS1W-DRM21(-V1) DeviceNet Unit?
The dimensions of the CS1W-DRM21(-V1) DeviceNet Unit are 30 mm x 90 mm x 56 mm.
What is the maximum number of nodes that can be connected to a DeviceNet network?
The maximum number of nodes that can be connected to a DeviceNet network is 64.
What is the baud rate of the DeviceNet Unit?
The baud rate of the DeviceNet Unit is up to 500 kbps.

advertisement

Table of contents