Pressure Relief Procedure

1.

Shut off feed pumps and agitator, if used.

2.

Turn PRESSURE RELIEF/DISPENSE valves (SA,

SB) to PRESSURE RELIEF/CIRCULATION

Route fluid to waste containers or supply tanks.

Ensure gauges drop to 0.

.

SA

SB ti9879a1

3.

For models with an dispense valve with a safety lock, engage gun safety lock.

4.

Relieve pressure in dispense valve. See dispense valve manual.