Appendix C - ADM Run Screens Overview

Appendix C - ADM Run Screens Overview

Run screens are divided into five major sections: status, errors, events, and maintenance. The following diagram demonstrates the flow of the Run screens beginning with the Home screen.

Home Status Errors #1

Errors #2

Errors #...

Events #1

Events #2

Events #...

Maintenance

F IG . 23: Run Screens Navigation Diagram

Home Screen

The Home screen is the first screen that displays in the

Run screens. It shows the current fluid pressure on the

A (Red) and B (Blue) fluid outlets of the pump and if there are any active errors. If tanks are installed in the system, the fill level is shown on each tank. The ratio is also displayed as either Red:1 or Blue:1 depending on which display has been setup.

To select an operating mode, press the Select Mode button repeatedly until the desired mode is shown then press the Enter button to select the mode.

Alternately, press the Select Mode button and use the up and down arrow keys until the desired mode is shown, then press the Enter button to select the mode. The available operating modes are operator, sequence, shot, standby, night, and disabled.

Home Screen, Disabled Mode

When this mode is selected, the machine will not be able to dispense or condition (heat/cool) material. The setup screens cannot be accessed while in Disabled mode. Use the Select mode button to exit Disabled mode.

* Supply tanks shown for reference only. Your system may not include supply tanks.

82 313997P

Appendix C - ADM Run Screens Overview

Home Screen, Standby Mode

In Standby Mode, the user can enable heating, park the pumps, refill the tanks, circulate materials.

Home Screen, Shot Mode

This mode allows the user to select one of 100 predefined shot numbers. See Shots Screen on page 69 for information about editing shot definitions.

To use a predefined shot:

1.

Enter shot mode.

2.

Press and use the numeric keypad to enter the desired shot number.

3.

Press to select the shot number.

Press to change operating modes.

Press to move the pumps all the way to the left and turns the hydraulic power pack off.

4.

Press to initiate a dispense. The system will go to high pressure mode and dispense a shot after the pre-dispense timer, see Mix Head Operating

Details Screen on page 74, expires.

NOTE: There is a three second delay after a dispense before another dispense can be initiated

Press or to initiate a tank refill. If a tank is filling, pressing either button will abort the filling operation.

Press to stop or start the hydraulic power pack and run the start-up process.

Target Flow

Ratio

Target recipe time

5.

Press to switch between low and high pressure modes without dispensing.

6.

During a dispense, press to abort the dispense.

7.

See

Home Screen, Standby Mode on page 83 for

other button functions.

313997P 83

Appendix C - ADM Run Screens Overview

Home Screen, Sequence Mode

This mode allows the user to select one of five sequences (A-E). The progress bar on the bottom of the screen shows the progress of a shot dispensing from the selected sequence. See

Sequences Screen

on

page 71 for information about editing sequence defini-

tions.

To use a predefined sequence:

1.

Enter Sequence Mode.

2.

Press the sequence letter/position selection button.

3.

Use the left and right arrows to toggle between letter and position selection. When selecting a sequence letter (A-E), use the up and down arrow keys to scroll through the available letters. When selecting a sequence position, type in the desired position with the numeric keypad. The system will reject invalid letter/position selections.

Home Screen, Operator Mode

This mode allows users to set a pressure or flow rate to dispense material without using predefined shot information. Pressure or flow rate availability is dependent on the Control Mode selection, see System Screen 2 on page 73.

1.

To edit the flow rate, press . The value to change will now be highlighted. Type the new value then press to accept it.

Ratio

Operator

Setting

4.

Press to accept the sequence letter/position.

5.

Press the Dispense button to begin dispensing.

A (Red) resettable material counter

B (Blue) resettable material counter

Total of resettable material counters

Target

Flow/Pressure

Ratio

Target dispense amount (time/volume/weight depending on Dispense Mode)

2.

Press to initiate a dispense. The system will go to high pressure mode and dispense a shot after the pre-dispense timer, see Mix Head Operating

Details Screen on page 74, expires. Press the to stop the dispense.

NOTE: There is a three second delay after a dispense before another dispense can be initiated.

3.

If an external trigger is used, press an hold the trigger to initiate a dispense. Release the trigger to stop the dispense.

4.

See Home Screen, Shot Mode on page 83 for other button functions.

6.

Press to skip to the next sequence position.

7.

Press to abort the sequence.

8.

See Home Screen, Shot Mode on page 83 for other button functions.

84 313997P

Home Screen, Night Mode

In Night Mode, the system will cycle on and off periodically. The recirculation on/off cycle begins automatically upon entering Night Mode. See

Conditioning Screen 3 on page 78.

Appendix C - ADM Run Screens Overview

Status Screen

The status screen provides all of the operational functionality of the Home screen except for operating mode selection. Refer to the Home screen and operating mode descriptions for information on this functionality.

In addition to the functionality provided by the Home screen, the Status screen also provides material conditioning information and control.

Home Screen, Disabled Mode

When this mode is selected, the machine will not be able to dispense or condition (heat/cool) material. The setup screens cannot be accessed while in Disabled mode. Use the Select mode button to exit Disabled mode.

No setpoint box will be displayed if selected as monitor zone.

313997P 85

Appendix C - ADM Run Screens Overview

Status Screen, Conditioning Control

This screen allows users to turn on and off heat zones individually or all at once. When a zone is on it is actively controlling temperature. Refer to the table below for color code definitions.

Zone

Setting

OFF

ON

Color

Black

Grey

Yellow

Green

Definition

Dispense Disabled

Dispense Allowed

Dispense Disabled

Dispense Allowed

Errors Screens

This screen shows users a list of errors that have occurred in the system. Each error entry includes a description and error code along with a date and time stamp. There are 5 pages, each holding 10 errors. The

50 most recent errors are shown.

Refer to the Troubleshooting section on page 58 for a

detailed description of all of the system errors.

To turn a single zone on/off:

1.

Press to enter the Conditioning Control screen.

2.

Use the arrows keys to navigate to the desired zone.

3.

Press to turn the selected zone on. When a zone is on, the button will be selected. Press the button again to turn the zone off.

To turn all zones on/off:

1.

Press to enter the Conditioning Control screen.

2.

Press the to turn on all zones. When one or more zones are on, the button will be selected.

Press the button again to turn all zones off.

Events Screens

This screen shows users a list of events that have occurred in the system. Each event includes a description and event code along with a date and time stamp.

There are 20 pages, each holding 10 events. The 200 most recent events are shown.

Refer to the Troubleshooting section on page 58 for a

detailed description of all of the system events.

All zones shown for reference. Only four zones may be active at one time.

No setpoint box will be displayed if selected as monitor zone.

86 313997P

Appendix C - ADM Run Screens Overview

Maintenance Screen 1

This screen displays historical information for each pump in the system. The Batch counters are resettable and count both material usage and pump cycles. The

Total counters are not resettable by the user. They also count both material usage and pump cycles. For material usage counters, units are displayed next to the volume/weight indicator icons.

To erase a batch counter, press the Enter Screen button and navigate to the field to be erased. Press the Erase

Single button to erase that data point. Alternatively, the

Erase All button may be pressed to erase all of the batch data points simultaneously.

Optional Screens

The optional Diagnostic screen can be enabled in the

Advanced Screen 4 screen, see page 81.

Diagnostic

The Diagnostic screen shows status information for various system components.

NOTE: In a circulation system, the pumpline must be stopped to erase counters.