Appendix E - System Events

Appendix E - System Events

Event Code and

String

REL00: System Powered On

Triggers

The System was powered on.

REM00: System Powered Off

The System was powered off.

REB00: Stop Button

Pressed

RECH0: Learn Mode

Executed

RENN0: Automatic

Cal. Performed

RECA1: Red Material SG Modified

The Red stop button was pressed on the Advanced Display Module.

A learn mode calibration was successfully completed.

The system was successfully characterized with the Automatic calibration.

The Red materials specific gravity was modified.

RECB2: Blue Material

SG Modified

The Blue materials specific gravity was modified.

RENC1: Cal. Point 1

Weight Entered

RENC2: Cal. Point 2

Weight Entered

RENC4: Cal. Point 1

Weight Erased

RENC5: Cal. Point 2

Weight Erased

REND0: Ratio Check

Dispense

A value for the first point in the three point calibration was entered.

A value for the second point in the three point calibration was entered.

The running average for point one of the three point calibration was erased.

The running average for point two of the three point calibration was erased.

A ratio check shot was dispensed from the ratio check calibration screen.

REA00: Disp.

Occurred (Shot #)

REH00: Gel Timer

Dispense

A dispense has occurred of the given shot number.

The gel timer expired and the system automatically took the gel shot.

RER01: Shot Count

Reset

RER02: Seq. Position Count Reset

A counter from the shot counters maintenance page was erased

A counter from the sequence counters maintenance page was erased

RERA1: Red Material Volume Reset

The resettable totalizer for the Red material volume was reset to zero.

RERB1: Blue Material

Volume Reset

The resettable totalizer for the Blue material volume was reset to zero.

RERA2: Red Material Weight Reset

The resettable totalizer for the Red material weight was reset to zero.

RERB2: Blue Material

Weight Reset

The resettable totalizer for the Blue material weight was reset to zero.

RERA3: Red Cycle

Count Reset

RERB3: Blue Cycle

Count Reset

REQU1: Settings

Downloaded

The resettable cycle counter for the

Red pump was reset to zero.

The resettable cycle counter for the

Blue pump was reset to zero.

The system settings were successfully transferred from the ADM to a

USB drive.

Event Code and

String

REQU2: Settings

Uploaded

REQU3: Language

Downloaded

REQU4: Language

Uploaded

REQU5: Logs Downloaded

REAR0: Night Mode

Recirc On

REBR0: Night Mode

Recirc Off

Triggers

The system settings file was successfully transferred from the USB drive to the ADM.

The custom language file was successfully transferred from the ADM to a USB drive.

The custom language file was successfully transferred from the USB drive to the ADM.

The Error/Event and Shot data logs were successfully transferred from the

ADM to a USB drive.

While in night mode the system has automatically entered a low recirculation mode and attempted to turn on all enabled conditioning zones.

While in night mode the system has automatically stopped the low recirculation mode and turned off all conditioning zones.

100 313997P

Appendix E - System Events

313997P 101

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Download PDF

advertisement

Table of contents