To avoid tip over, make sure cart is on a flat and level surface. Failure to do so could result in injury or equipment damage.

1.

Check packing nut (D). Fill with Throat Seal Liquid

(TSL). Torque to 25 ft-lb (34 N•m).

D

NOTICE

The minimum hose size allowable is 3/8 in. ID x 50 ft

(10 mm x 15 m). Smaller hoses can cause high pressure spikes and result in damage to the sprayer.

3.

Attach hose to gun and tighten.

4.

Attach material supply inlet hose to pump lower.

NOTE: Maximum suggested length is 6 ft (1.8 m), minimum suggested inner diameter is 1 in. (2.5 cm).

5.

Pull pressure adjustment knob (H) out and turn counterclockwise until it stops. Push the knob in to lock.

H

WLE

2.

Attach electrically conductive fluid hose to pump lower outlet via outlet check valve and tighten.

NOTICE

Attaching the hose directly to the lower pump can result in damage to the sprayer during cavitation, or when the sprayer runs out of material. Use an outlet check valve between the lower pump and hose to avoid damage.

ti20171a_1

6. Turn power switch (E) OFF. Connect unit to power

source. See F IG . 3, page 6.

7.

Always flush and prime sprayer before each use