Spray. Graco 333208E, Electric High Pressure Airless Sprayer

Add to my manuals
28 Pages

advertisement

Spray. Graco 333208E, Electric High Pressure Airless Sprayer | Manualzz

Spray

Spray

6.

Disengage gun trigger lock.

NOTICE

Do not allow pump to run dry. It will quickly accelerate to a high speed causing damage.

1.

Perform Prime

procedure, page 11.

2.

Perform

Pressure Relief Procedure , page 10.

3.

Install tip and tip guard onto gun.

4. Turn power switch (E) ON.

ti5048b

7.

Spray a test pattern. Read fluid manufacturer’s recommendations. Adjust as necessary.

21

E WLE

5.

Pull out and turn pressure adjustment knob (H) until desired pressure is reached. Turn clockwise to increase pressure, counterclockwise to decrease pressure. Push knob in to lock.

H

+

_

8.

Flush when finished spraying. See Prime/Flush ,

page 11.

9.

Perform

Pressure Relief Procedure , page 10.

Shutdown

NOTICE

Never leave water or water-based fluid in pump over night. If water-base fluid has been used, flush with water first, then with a rust inhibitor (such as mineral spirits). Relieve pressure, but leave rust inhibitor in pump to protect parts from corrosion.

ti20171a_1

To shutdown, perform Prime/Flush

procedure, page 11.

Perform

Pressure Relief Procedure , page 10.