To reduce the risk of electric shock, fire and explosion, all electrical wiring must be done by a qualified electrician and comply with all local codes and regulations.

See Driver Installation manual for instructions for power requirements.

code requires redundant grounding connections.

2.

Ground the object being sprayed, fluid supply container, and all other equipment in the work area. Follow your local code. Use only electrically conductive air and fluid hoses.

3.

Ground all solvent pails. Use only metal pails (5 gallon (19 liter) metal pail, Graco part 101108

– not supplied), which are conductive, placed on a grounded surface. Do not place pail on a non-conductive surface, such as paper or cardboard, which interrupts grounding continuity.

See Driver Installation manual for instructions to connect power.

gun/dispense valve firmly to the side of a grounded metal pail, then trigger the gun/valve.

1.

Loosen the ground screw (Y) and attach a ground wire (Graco part 244524 – not supplied). Tighten the ground screw securely. Connect the other end of the ground wire to a true earth ground.

This equipment must be grounded to reduce the risk of static sparking and electric shock. Electric or static sparking can cause fumes to ignite or explode. Improper grounding can cause electric shock. Grounding provides an escape wire for the electric current.

cord.

with a maximum of 210 ft. (64 m) combined hose length to ensure grounding continuity. Check electrical resistance of hoses. If total resistance to ground exceeds 25 mega ohms, replace hose immediately.

grounded fluid hose and pump.

The driver gear box is shipped from the factory pre-filled with oil. The temporary unvented cap (PX) prevents oil leaks during shipment. This temporary cap must be replaced with the supplied vented oil cap (P) before use.

P

PX code. Use only conductive metal pails, placed on a grounded surface. Do not place the pail on a non-conductive surface, such as paper or cardboard, which interrupts grounding continuity.

8

ti31010a

3A8126A

Installation

The pump fluid section was tested with lightweight oil, which is left in the fluid passages to protect parts.

To avoid contaminating your fluid with oil, flush the equipment with a compatible solvent before using the equipment.

See

Prime/Flush, page 14 .