Installation

Grounding

The equipment must be grounded to reduce the risk of static sparking and electric shock. Electric or static sparking can cause fumes to ignite or explode. Improper grounding can cause electric shock. Grounding provides an escape wire for the electric current.

The DCM and ADCM are used in a variety of systems, with varying grounding requirements.

Follow all instructions in your system manual.

Non-

Hazardous

Area

Non-

Hazardous

Area

Hazardous

Area

Hazardous

Area

8

A

B

Power Supply Located in Non-Hazardous Area Power Supply Located in Hazardous Area

KEY

DCM or ADCM

Power Supply and Barrier

Power cable CANNOT have cable shield tied to coupling nut. 500 VAC isolation is required.

The power cable and circuit board are isolated from the DCM/ADCM enclosure. They have conductive paths to SEPARATE grounds.

Power cable CAN have cable shield tied to coupling nut. Power cable coupling nut and

DCM/ADCM have conductive path to COMMON ground.