Electrical. Duluth Forge 170154, 170032, 170150

Add to My manuals
36 Pages

advertisement

Electrical. Duluth Forge 170154, 170032, 170150 | Manualzz

ELECTRICAL

ELECTRICAL CONNECTION

FOR STOVES EQUIPPED WITH A BLOWER

Do not use this stove if any part of it has been under water.

Immediately call a qualified service technician to inspect the stove and replace any part of the electrical system which has been under water.

a properly grounded outlet box. The adapter should not be used if a three-slot grounded receptacle is available.

A

GROUNDING INSTRUCTIONS

This stove is for use on 120 volts. The cord has a plug as shown at A in Figure 34. An adapter as shown at C is available for connecting three-blade grounding-type plugs to two-slot receptacles. The green grounding lug extending from the adapter must be connected to a permanent ground such as

Grounding Pin

B

Cover of

Grounded

Outlet Box

C

Metal Screw

Adapter

(Sold

Separately)

Grounding Means

Figure 34 - Grounded Electrical Outlet

ELECTRICAL WIRING

Any electrical re-wiring of this stove must be done by a qualified electrician. This wiring must be done in accordance with local codes and/or in Canada with the current CSA C22.1

Canadian Electrical Code , and for US installations, the National Electrical Code ANSI/

NFPA NO 70 .

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.

WARNING: If repairing or replacing any electrical component or wiring, the original wire routing, color coding and securing locations must be followed.

26 www.factorybuysdirect.com

200253-01E

ELECTRICAL

WARNING: Never attempt to service stove while it is plugged in, operating, or hot. Burns and electrical shock could result.

Only a qualified service person should service or repair stove.

Verify proper operation after servicing. If any of the original wire as supplied with the stove must be replaced, it must be replaced with a wire of at least a 105º C temperature rating.

LEARN

120V 60Hz

WARNING: as shown in diagrams. Installation and service should be done by qualified service technician only.

Natural Gas

Make sure Regulator Cap is in the appropriate position

Propane/LP Gas

DC 6V 1.5A

Adaptor

When using natural gas:

Make sure the cap is installed in the propane/LP inlet of regulator.

Use thread sealant to assure there are no leaks.

When using propane/LP gas:

Make sure the cap is installed in the natural gas (NG) inlet of regulator.

Use thread sealant to assure there are no leaks.

ADVERTENCIA: por un técnico de servicio calificado solamente.

ON REMOTE OFF

Gas Natural

Cuando se utiliza gas natural:

Asegúrese de que la tapa está instalado en el propano/LP entrada del regulador.

Utilice sellador de roscas para asegurar que no haya fugas.

Propano/LP Gas

Cuando se utiliza el gas propano / LP:

Asegúrese de que la tapa está instalado en la entrada de gas natural (GN) del regulador.

Utilice sellador de roscas para asegurar que no haya fugas.

Reciever

(4 AA Batteries Required)

Correct Pilot Flame Pattern

1/2 Glass

Height

Correct Burner Flame Pattern

Yellow

Tipping

NG

3-3.5" WC

LP

8-11" WC

Incorrect Pilot Flame Pattern

Incorrect Burner Flame Pattern

LP

Blue Plunger

NG

Yellow Plunger

INSTALL SUPPLIED CAP IN FITTING

NOT BEING USED.

INSTALAR TAPA SUMINISTRADA MONTAJE NO SE UTILIZA.

Gas Inlet / Gas esté

INLET GAS PRESSURE MAX 1/2 PSIG (3.5 KPa)

Yellow Black

WARNING: Make sure the supplied cap is installed in unused regulator fitting before connecting the correct gas supply line.

WARNING: Do not use natural gas and propane gas together.

CAUTION: Two gas line installations at the same time are prohibited.

ADVERTENCIA: Asegúrese de que la línea no utilizado se conecta por primera vez antes de conectar la línea de suministro de gas correcta.

ADVERTENCIA: No utilice el gas natural y el gas propano juntos.

PRECAUCIÓN: Dos instalaciones de líneas de gas al mismo tiempo están prohibidos.

FOR PROPANE GAS SUPPLY

PARA LA FUENTE DE GAS DEL PROPANE

CAUTION: The heater requires an external regulator to reduce the LP tank pressure to a maximum of 14" W.C. Never connect this product directly to the supply tank.

PRECAUCIÓN: El calentador requieres una externa regulador para reducir la presión del tanque de gas a un máximo de 14"

W.C. Nunca conecte este producto directamente al tanque de suministro.

FOR NATURAL GAS SUPPLY

PARA LA FUENTE DE GAS DEL NATURAL

NOTICE: An additional gas regulator will be necessary if the local natural gas pressure exceeds the heater's rated maximum inlet pressure. If in doubt, contact the local gas utility. If natural gas inlet pressure exceeds 10" W.C., the safety pressure switch will activate. See owners manual for proper procedure to bypass the pressure switch.

AVISO: Un regulador de gas adicional será necesario si la presión del gas natural local excede de entrada nominal máxima del calentador presión. En caso de duda, póngase en contacto con la compañía de gas local. Si la presión de entrada de gas natural supera los 10" WC, el interruptor de presión de

This appliance may be installed in an aftermarket,* permanently located, manufactured (mobile) home, where not prohibited by local codes.

This appliance is only for use with propane or natural gas.

Field conversion by any other means including the use of a kit is not permitted.

Procom Heating, Inc. U.S. Patent Information

This product may be covered by one or more of the following

United States patents:

8,915,239 8,851,065 8,764,436 8,757,202 8,757,139 8,752,541

8,568,136 8,545,216 8,517,718 8,516,878 8,506,290 8,465,277

8,317,511 8,297,968 8,281,781 8,241,034 8,235,708 8,152,515

8,011,920 7,967,006 7,967,007 7,654,820 7,730,765 7,677,236

7,607,426 7,434,447

Other patents pending.

Power

Change

Assembly

Power Change

Assembly

Pin and Socket Connector

Black

Red

Valve