Set Auto Power Off for Host Indicator. BALZER FIELD FLOATER 6

Add to My manuals
108 Pages

advertisement

Set Auto Power Off for Host Indicator. BALZER FIELD FLOATER 6 | Manualzz

WEIGH SYSTEM PROGRAMMING

Host Indicator Programming (Continued)

Set Auto Power Off for Host Indicator

The following steps will set the amount of time with no activity to the indicator before it turns itself off NOTE: THE INDICATOR

WILL NOT AUTOMATICALLY TURN ON WHEN ACTIVITY RESUMES

Step

Set Auto Off time delay

Button Entry Option Display

Select inactivity time delay

Use numeric keypad to enter time delay

Accept your time delay

The default selection is 000 - this will leave the unit on until either manually turning off with the power button or power is shut off to the unit when the tractor is shut off

The scale indicator can accept a time delay from 1 to 240 (in minutes)

Set Hold Enable for Host Indicator

The following steps will activate or deactivate the button feature which will hold the current weight received from the load cells When a HOLD is activated, the display will alternate between the word HOLD and the displayed weight NOTE: THE

INDICATOR WILL NOT UPDATE OR RECORD NEW WEIGHT RECEIVED FROM LOAD CELLS

Step Button Entry Option Display

Set Hold Enable

Select No or Yes The default selection is No - display will be flashing

Switch to Yes to activate the Hold Enable

Accept your selection

Set Print Continuous for Data Output

The following steps will set the indicator for continuous data output to the RS232 port

Set Print Continuous

Step Button Entry Option

Select No or Yes The default selection is No - display will be flashing

Switch to Yes to activate continuous data output

Accept your selection

Display

66 Field Floater 6 Grain Cart User Manual