Set RS232 Port Baud Rate. BALZER FIELD FLOATER 6

Add to My manuals
108 Pages

advertisement

Set RS232 Port Baud Rate. BALZER FIELD FLOATER 6 | Manualzz

WEIGH SYSTEM PROGRAMMING

Host Indicator Programming (Continued)

Set RS232 Port Baud Rate

The following steps will set the output data rate of the RS232 serial port to match that of an external display/reporting device

Step Button Entry Option Display

Set Baud Rate

Select Baud Rate The default selection is 9600 - display will be flashing

Cycle through baud rate selections of 1200,

2400, 4800, 9600, 19200, 38400, 57600, and

115200

Accept your selection

Calibration Menu System

The following options are accessible through the calibration menu system:

Display Function Definition

Calibration Step Code Default is 000 This continues through the main calibration menu There are no user serviceable Calibration Sub menus

Read Only Mode

Radio Enable

Radio Channel

This option is for when multiple host indicators are used with the same scale indicator It is not applicable to this grain cart configuration as it is delivered

Allows the host indicator to communication wirelessly with other compatible equipment and devices

Sets the radio channel when the radio is enabled There are 12 radio channels available

Radio Network ID Sets the radio’s network identification (0-65534) for the radio channel being used

Radio Encryption

Enable and Key

Restore Radio

Defaults

Turning on the radio encryption makes the transmitted signal unable to be decoded without the receiver having the same encryption key (encryption key value range: 0-65534) NOTE: IF YOU FORGET THE ENCRYPTION

KEY VALUE, YOU WILL NOT BE ABLE TO CONNECT A RECEIVING

DEVICE

Default is 0 This leaves the radio settings as they have been programmed

Entering 3 will restore the radio settings to their default values

Unit Switch Enable Allows the changing of weighing units from pounds (lbs) to kilograms (kg) through the main menu

Auto Zero Tracking Automatic adjustment to the scale should the zero reading drift from the set zero of the scale

Graduation Size Set weighing incremental count