Operation. Everbilt EB-PUMP-T
Everbilt EB-PUMP-T is a condensate pump designed to automatically remove condensate water from air conditioners and other appliances. It features a built-in tank that collects water and switches on to pump it away when the water level reaches a certain point. The pump can lift water up to 20 feet and has a check valve to prevent backflow. The LED indicator provides information about power availability, motor operation, and high water conditions.
Annonce
Annonce
Operation
1
Testing the pump
□ To test the float (1), manually fill the tank with water. An amber LED (2) will indicate correct float operation.
2
Testing the overflow switch
□ To test the overflow safety switch (C) (if connected), manually overfill the tank with water. If the overflow safety switch is working correctly, the A/C unit / furnace will shut down (if wired to condensate pump) and a red
LED (1) will illuminate.
8
1
1
2
Operation (continued)
LED INDICATOR STATUS
LED
Green LED
Amber LED
Red LED
Status
Indicates that the A/C system circuit is enabled and the pump is ready.
Indicates that the pump is running and removing condensate from the tank.
Indicates that the pump is in alarm mode and that the system is shutoff/disabled (if connected).
Care and Maintenance
□ Always disconnect power before performing maintenance. Pump and deck may be removed from the tank by pushing tabs located on the tank sides away from the deck while lifting on the pump cover.
□ Periodically inspect the condensate pump tank to assure it is free of accumulated dirt or sludge. Do not use solvent cleaners. Clean tank with soap and warm water only. The check valve may be removed for cleaning or replacement by unscrewing with a 9/16 in. wrench.
□ Clean inlet and outlet piping.
□ Reassemble system and check for correct operation.
Troubleshooting
P r o b l e m
The pump does not start when full of condensate.
Condensate is pump.
The pump will not shut off.
P o s s i b l e C a u s e
□ Power is not supplied to the pump.
□
□
The pump impeller is not turning.
□ Power is not supplied to the pump.
C o r r e c it v e A c it o n
□ Ensure that power is supplied to the pump. A green LED indicator on the top of the pump cover will show that power is supplied and that the pump is ready.
□ Clear any blockage in the impeller housing. If the problem persists, the motor is stuck. Contact the manufacturer. There are no user serviceable parts.
□ Ensure that power is supplied to the pump. A green LED indicator on the top of the pump cover will show that power is supplied.
□ ow to the condensate pump is exceeding the outlet
□ The pump is not level.
is connected to the A/C / furnace unit. The safety switch connection will shut off the A/C / furnace in this condition.
□ Check to ensure that the pump is level. If the pump is not level, it
□
□
□
□
ow is blocked.
The pump impeller is not turning.
ow is blocked.
at and level surface.
□ Check outlet tubing to ensure that it is not kinked or blocked.
Clear blocked tubing of slime and debris. Clean inlet and outlet piping.
□ Clear any blockage in the impeller housing. If the problem persists, the motor is stuck. Contact the manufacturer. There are no user serviceable parts.
□ ow to the condensate pump is exceeding the outlet is connected to the A/C / furnace unit. The safety switch connection will shut off the A/C / furnace in this condition.
□ Check outlet tubing to ensure that it is not kinked or blocked.
Clear blocked tubing of slime and debris. Clean inlet and outlet piping.
9 H O M E D E P O T .
C O M
P l e a s e c o n t a c t 1 8 77-528-3878 f o r f u r t h e r a s s i s t a n c e .