Installation

STEP 3

Dimensions and Clearances

• Before installing the range, you must locate and secure the included anti-tip bracket to the wall for your range.

• The range may be installed flush to the rear wall. You may install a non-combustible material on the rear wall above the range and up to the vent hood. It is not necessary to install non-combustible materials behind the range below the countertop height.

• The minimum distance from the side of the range above the countertop to combustible sidewalls must be at least 10 inches.

18” (45.7 cm) Min.

13” (33 cm) Max.

30”(76.2 cm) Min.

36”(91.4 cm) Max.

1/4”

(0.6 cm)

36” (91.4 cm)

Figure 3

STEP 4

Gas Connection

For NG, input pressure is 7” W.C. and output pressure 5” W.C.

For LP, input pressure is 11” W.C. and output pressure: 10” W.C.

Appliance regulator is set at 5.0” W.C. outlet pressure.

The gas supply pressure for checking the regulator setting is 5” (Natural Gas) and 10” (LP gas). Connect flexible gas line connector to the regulator on the range. Position range to permit connection at the shut off valve.

DANGER:

The gas supply line must be equipped with an approved manual shut-off valve. The shut-off valve must be in an easily accessible location in the same room as the appliance. Do not block access to the shut-off valve. Be sure you know how and where to shut off the gas supply to the range.

The pressure regulator located at the inlet of the appliance manifold must remain in the supply line regardless of Natural

(NG) or Liquid Propane (LP) gas is being used.

A flexible metal appliance connector used to connect the appliance to the gas supply should be 3 feet/91.4 cm max. in length for easy installation. In Canada, flexible connectors should be single wall metal connectors less than 6 feet/182.9 cm in length.

— 15 —

Installation

STEP 4 (Continued)

Gas Connection

WARNINGS:

• Please make sure to read ALL safety precautions on pages 4 to 10.

• Explosion Hazard.

• Use a new CSA International approved gas supply line.

• Install a shut-off valve.

• Securely tighten all gas connections.

• If connected to LP, have a qualified person make sure gas pressure does not exceed 12” (30 cm) water column.

Examples of a qualified person include: licensed heating personnel, authorized gas company personnel, and authorized service personnel.

• Failure to do so can result in death, explosion, or fire.

u Shut off the main gas supply valve before removing the old cooking appliance (if applicable) and leave it off until the new hook-up has been completed. Don’t forget to relight the pilots on other gas appliances when you turn the gas back on. w Use a flexible gas line to connect to the 1/2” fitting, located on the bottom right hand corner underneath the appliance.

v Because hard piping restricts movement of the appliance, the use of a CSA certified flexible metal appliance connector is recommended unless local codes require a hard-piped connection. Never reuse an old connector when installing a new appliance. If the hard piping method is used, you must carefully align the pipe.

To prevent gas leaks, use pipe joint compound resistant to NG gases on all male external pipe threads.

x When all connections have been made, be sure all appliance controls are in the off position and turn on the main gas supply valve. Check for gas leaks by using a 75% water,

25% dish washing soap solution. If a gas leak occurs, shut off gas immediately, tighten all connections, and retest for leaks.

Figure 4

DANGER:

• Please make sure to read ALL safety precautions on pages 4 to 10.

• Do not use a flame to check for leaks from gas connections. Checking for leaks with a flame may result in a fire or explosion.

• Tighten all connections if necessary to prevent gas leakage in the appliance or supply line.

• Check alignment of control knob valves after connecting the appliance to the gas supply to be sure the appliance manifold pipe has not moved. A misalignment could cause the valve stems to rub on the control panel, resulting in a gas leak at the valve.

• Disconnect this appliance and its individual manual shut-off valve from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa or 12” water column).

• Isolate the appliance from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa or 12” water column).

After installation:

• Check ignition of cooktop burners.

• Check the air shutter adjustment – sharp blue flame, with no yellow tipping or lifting flames.

• Check ignition of oven burner.

• Visually check tubular burner (oven burner) re-ignition to be sure both rows of burner ports are relighting each time.

• Check for gas leaks at all gas connections (using a gas detector, never a flame).

• Check oven bake and convection bake function.

— 16 —