Step 5 - Liquefied Petroleum (Propane) Gas Conversion. Ancona AN-2330SS, AN-2348SSRD, AN-2336SSRD, AN2336SSRD, AN-2348SSWHT, AN-2348SSBK, AN-2330SSRD, AN-2330SSWHT, AN-2330SSBK, AN-2336SS

Add to my manuals
32 Pages

advertisement

Step 5 - Liquefied Petroleum (Propane) Gas Conversion. Ancona AN-2330SS, AN-2348SSRD, AN-2336SSRD, AN2336SSRD, AN-2348SSWHT, AN-2348SSBK, AN-2330SSRD, AN-2330SSWHT, AN-2330SSBK, AN-2336SS | Manualzz

Installation

STEP 5 (Optional)

(Must be done before Step 6 if converting to Propane)

Liquefied Petroleum (Propane)

Gas Conversion

This appliance can be used with Natural Gas or LP/Propane

Gas. It is shipped from the factory for use with Natural Gas. A kit for converting to LP gas is supplied with your appliance.

The kit is marked “FOR LP/PROPANE GAS CONVERSION”.

w x

Unscrew the regulator cap with a wrench (see Figure

6).

Remove retainer pin by pulling it out (see Figure 7).

Figure 7

WARNINGS:

• Please make sure to read ALL safety precautions on pages 4 to 10.

• Failure to make the appropriate conversion after

Step 4 can result in serious personal injury and property damage.

• The conversion must be performed by a qualified service technician in accordance with the kit instructions and all local codes and requirements. Failure to follow instructions could result in serious injury or property damage. The qualified agency performing this work assumes responsibility for the conversion.

y Reverse the retainer pin and snap it back into the regulator cap (see Figure 8).

Figure 8 u When the appliance is converted for Liquid Petroleum

(LP) Gas, the LP gas supply is required to provide a minimum of 10” to a maximum of 12” water column to the appliance regulator.

Following LP Gas

Conversion, complete steps: “Adjusting the

Regulator Pressure”;

“Changing Burner

Nozzles”; “Adjusting

Burner Flames”; and

“Testing Flame Stability” .

Figure 5

U Screw the regulator cap back into the regulator and re-attach it to the nipple and flare union as shown.

DO NOT over-tighten (see Figures 9 and 10).

Adjusting the Regulator Pressure

v Shut off the gas supply to the appliance by closing the manual shut-off valve

(see Figure 5). Disconnect electrical power to the appliance before servicing. Do not remove regulator or allow it to turn during servicing.

Manual

Shut off

Valve

Flare

Union Gas Flow

Figure 9

Flare

Union

Pressure

Regulator

Figure 6

— 17 —

On

Off

Joint Joint

Access

Cap

Figure 10

advertisement