- Timer. Panasonic KYT936SLEPG, KYT935XLEPG


Add to my manuals
80 Pages

advertisement

- Timer. Panasonic KYT936SLEPG, KYT935XLEPG | Manualzz

Dimensions

Top View

520

900

(measurement: mm)

Front View

52

900

6

Side View

52

Front side

Exhaust vent

520

Intake vent

6

Rear side

EN-

42

Power cord length: approx. 1.2 m (Sheath length: approx. 1.1 m)

Dimensions

Side View

(measurement: mm)

CAUTION

If this condition is not met, do not install the appliance.

Minimum 30 for flat part

490

- 0

Min. 40

Min. 20

Front side

Partition

Flow of intake and exhaust

Rear side

When Installing a Partition Inside the Cabinet

Allow for a minimum of 20 mm extra space underneath the bottom of the appliance for air circulation.

Allow for a minimum of 40 mm extra space in rear of the partition.

Top view of the partition

Partition

Building rear wall

70

265

Countertop cutout

870

Countertop front

EN-

43

EN-

44

Dimensions

When Installing Above an Oven

The appliance may only be installed over a Panasonic oven.

Allow for extra spaces for air circulation as shown below.

(measurement: mm)

Side View with an Oven

Min. 60

Oven

Flow of intake and exhaust

Oven

Dimensions of Countertop Cutout

Building rear wall

Min.51

R3 1

3 0

Min.51

Building side wall

Min. 59

870

Countertop front

Min.51

Building side wall

Electrical Work

WARNING

Electrical work must be performed by a legally qualified electrician.

Electrical Requirements

This appliance must be supplied with the proper voltage and frequency, and connected to an individual, properly earthed branch circuit, protected by a circuit breaker or fuse. (The rating plate is on the bottom of the appliance.)

Min. 60 under overvoltage category III conditions. Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules.

Single-phase A.C. 220-240 V, 50 Hz electrical system must be used. (It is also possible to use a three-phase electrical system.) If connecting to aluminium wiring, use connectors approved for use with aluminium wiring.

Check with the local utilities for electrical codes applied in the area. Failure to wire the appliance according to governing codes may result in a hazardous condition.

After installation, show the customer where the breaker for the appliance is located.

Installation of the Earth Leakage Circuit Breaker

In accordance with the electrical wiring rules, incorporate the earth leakage circuit breaker in the home electrical wire.

Follow the specification of the earth leakage circuit breaker as follows.

Rated current: 50 A*, rated sensitivity current: 30 mA

* If rated current is 40 A, please change to 7200 W under “Power Management” in settings.

(See page 11)