For models ZIFI240, ZIFS240, ZIBI240, ZIBS240

THE INSTALLATION SPACE

All models may be used freestanding.

NOTE: If installing between frameless cabinets, a 1/2” wide filler strip or side panel may be needed on the hinge side. The filler strip will act as a spacer between the door case and adjacent cabinet and will prevent interference with the cabinet door swing. The width of the opening must include the filler panels.

Additional Specifications

• A 120 volt 60Hz., 15 or 20 amp power supply is required. An individual properly grounded branch circuit or circuit breaker is recommended. Install a properly grounded 3-prong electrical receptacle recessed into the back wall as shown. Electrical must be located on rear wall as shown.

NOTE: GFCI (ground fault circuit interrupter) is not recommended.

• Products must operate from separate, properly grounded receptacles.

Black or Stainless Steel Toekick Options

• These products are shipped with a stainless steel toekick and a black toekick. For shipping purposes, one of the toe kicks will be secured to the back of the unit, and the second will be installed on the unit. Keep the unused toekick and any unused parts for future use.

SIDE-BY-SIDE INSTALLATIONS

For a complete refreshment center, Install a fresh food refrigerator beside a Double-Drawer refrigerator,

Beverage Center, or Wine Chiller/Wine Reserve.

• A side by side installation requires minimum width openings depending on if the product will be flush or standard mounted and if there are stainless or custom panels. See chart below.

• For a standard installation: The product must be installed so that the product front will project forward of the adjacent cabinets by the dimensions T or U according to the model in the chart. This position will allow a full door swing and prevent interference with adjacent cabinetry. The opening between cabinets must be a minimum of dimension K.

Panel

Stainless

Stainless

Custom

Mount Depth Style

Flush

Standard

Flush

Minimum width

Opening

L

M

M

L

NOTE: To minimize interference when products are placed side by side, adjust door swing to put hinges farthest away from each other and handles closest to each other. Please consult model availability to ensure

WKHFRQ¿JXUDWLRQQHHGHGLVDYDLODEOH

NOTE: Gap between units for Stainless is 1/4”.

Gap between units for Custom Panels is 1/2”.