Design Guide

For Models ZIFI240 and ZIBI240 with Custom Door Panels and Handles for Standard Installation only

THE INSTALLATION SPACE

Standard installation

The product must be installed so that the product front will project forward of the adjacent cabinets by the dimensions T or U according to the model in the chart.

This position will allow a full door swing and prevent interference with adjacent cabinetry. The opening between cabinets must be a minimum of dimension K.

CABINET

Standard

Installation

Front edge of product case

CABINET

PRODUCT CLEARANCES

For Models ZIFI240 and ZIBI240 both are set at 110° door swing from factory with no adjustment or 90° stop.

When installed in a corner:

• Allow 16” minimum clearance on the hinge side for a full 110° door swing.

• Allow 4-1/2” min. clearance on the hinge side for the

90° door swing and to allow racks to slide out.

16" Minimum to Wall

90 Door

Swing

B

110 Door

Swing R

F

90

110

4" Minimum to Wall

Front face

T,U

In a standard installation, the product will project forward of adjacent cabinets. See T,U.

110°

T ZIFI240

U ZIBI240

2-3/4”

2-5/8”

NOTE: Custom handle clearances may vary.

NOTE: Right hand models illustrated. Allow the same clearances on the opposite side for left hand fresh food model ZIFI240 only. Model ZIBI240 is not available with left hand door swing.

• Test the door swing. Carefully open and close the door. The door should not rub or catch on adjacent cabinetry.

NOTE: When installing custom panel and handle, use above clearances as a general guide but adjust according to the installation.

Choose the location:

• These products may be closed in on the top and three sides as long as the front is unobstructed for air circulation and proper access to the door.

• Do not install these products where the temperature will go below 55°F (13°C) or above 100°F (37°C).

• These products are not designed to be stacked one over the other.

Important: Model ZIBI240 is not available with a left hand door swing. DOOR HINGE IS NOT REVERSIBLE.