Fluid Commander

Fluid Management System

Features and Benefi ts

• Provides increased accuracy over mechanical counters

• PIN code prevents unauthorized dispensing

• Dispense totals tracked by location

• Easy to read display

• Accurate controlled dispense with parts room authorization

Typical Applications

• Parts room authorized dispensing for inventory control

• Automotive dealerships

• Heavy-duty dealerships

• Fleet service facilities

Typical Fluids Handled

• Petroleum- and synthetic-based oils

• Anti-freeze

Technical Specifi cations

Maximum Number of Fluids ........................................................................ 1 or 2

Dispense Stations/Bays ............................................................................ 6 or 12

Air Solenoids Required .................................................................... 1 (per pump)

Fluid Solenoids Required ........................................... 1 (per fl uid dispense station)

Electrical Requirements .................................................... 120 V, 60 Hz, .25 amps

Weight .................................................................................... 4 lb, 5 oz. (8.0 kg)

Wiring Requirements ......................................................................... 90V; 2-wire

Distance/Gauge .....200 ft (61 m) = 18 gauge, 201 to 500 ft (61 m to 152 m) = 16 gauge, ...........................................................501 ft (152 m) or more = 14 gauge

Instruction Manual ................................................................................. 308238

Easy to Use

1. Service technician enters the service bay number, type of product, and amount to be dispensed, then activates the dispense button.

2. A “ready” light (located on the hose reel or dispense bar of the target service bay) signals when dispensing can begin.

3. As fl uid is dispensed, the Fluid Commander tallies the amount dispensed and shuts-off when the pre-set amount is reached.

No further dispensing takes place until new dispensing data is entered.

Typical Fluid Commander System Layout

10

L U B R I C A T I O N E Q U I P M E N T

F L U I D M A N A G E M E N T

A. Control*

B. Pressure Relief Kit**, 237893, 1-1/2 npt (m x f)

C. Supply Tank

D. Air Shutoff Valve, bleed-type

E. Air Filter

F. Air Solenoid Valve, 215407*

G. Air Regulator, 202156

H. Pump

J. Flexible Hose, 3-6 ft (0.9-1.8 m) long

K. Check Valve, 111620 (required)*

L. Fluid Filter, 223179

M. Pulse Meter, 236763 or 236764

N. Fluid Shutoff Valve, 108458, 1/2"

P. Fluid Solenoid Valve***, 215487*

Q. Hose Reel

R. Ready Light, 238996***

S. Dispense Valve

*These parts are included with model 232076, 240448, or 241905

** Kit required to protect system from rupture due to thermal expansion of fl uid lines. See instruction manual 308403.

** *218588 includes 238996 and 215487.

Note: For tank packages, pressure reliefs from instruction manual 308403 must be installed on outlet with pressure going either back to vent into the tank or to a container installed under the exit or relief valve.

www.graco.com

Fluid Commander

Fluid Management System

Ordering Information

Fluid Commander Systems

232076

240448

U.S. Measure Fluid Commander System for 2 products and 6 stations. Includes: One 2-product/6station Fluid Commander ( 235532), oil meter ( 236763), fl uid solenoid valve ( 215487), air solenoid valve ( 215407), Check valve ( 111620).

Metric Measure Fluid Commander System for 2 products and 6 stations. Includes: One 2-product/6station Fluid Commander ( 232077), oil meter ( 236764), Fluid Solenoid valve ( 215487), Air Solenoid valve ( 215407), check valve ( 111620).

Accessories

111620 Check valve

236763 Electronic Pulse Meter (quarts)

236764 Electronic Pulse Meter (liters)

215474 Mechanical Pulse Meter (quarts)

215745 Mechanical Pulse Meter (liters)

244342

Meter Pulse Converter, used when upgrading old-style modular fl uid commander to electronic allows use of 215474/ 215475 with the EFC. Instruction manual 309276

Air Solenoid Valves

215407

Air Solenoid Valve, 150 psi (10 bar) (1/2 npsm(f) conduit ports for wiring; 1/4 npt(f) air ports, adapted to 3/8(f) IN, 3/8(m) OUT) operates on 24V DC and 110 VAC. Automatically shuts-off air inlet to pump when pre-set dispensed amount is reached. Materials of construction: brass, SST, Buna.

105474

Air Solenoid Valve (bare) 150 psi (10 bar), same as 215407 but without wire connectors or adapters.

1/2 npsm(f) conduit ports for wiring; 1/4 npt(f) air ports.150 psi (10.3 bar) max. working pressure.

Fluid Solenoid Valves

215487

Fluid Solenoid Valve, 1/2 npt(f) 3000 psi (207 bar) operates on 24V DC. Automatically shuts-off fl uid when pre-set dispensed amount is reached. Includes tube, valve, pin connector, wire plug connector and adapter.

514150 Fluid Solenoid Valve for anti-freeze, 150 psi max. (10 bar), 1/2 npt(f), same as features as 215487

110025

Bare Fluid Solenoid Valve, 1/2 npt(f) 3000 psi, same features as 215487 above, but without wiring connectors or adapters.

Ready-Light Kits

218588

Ready-Light Kit, signals operator when dispensing can begin. Includes “ready to dispense” Indicator

Light ( 239019), Strainer ( 240417), Fluid Solenoid Valve ( 215487) and hardware. Manual 307696.

238996 Ready-Light with Junction Box (no solenoid or strainer)

239019 Ready-to-Dispense Indicator Light only

113859 Lamp for Indicator Only

Installation Components

223179 Fluid Filter Kit (for bare electronic meter)

186472 Wall-Mounting Bracket

108458 Fluid Shut-Off Valve

237893

Thermal Relief Kit for 900 psi (62 bar), relieves excess heat-induced pressure from dispense system.

Male and female ends allow for simple installation. Instruction manual 308403.

Connecting Cables for Connecting Solenoids and Consoles. 90-volt, 2-wire, 18-gauge.

215481 100 ft (30.5 m) pre-connected at both ends

215407

215487

215481

www.graco.com