Chapter 6 Maintenance - Maintenance/replacement

Maintenance/replacement

Before performing maintenance/replacement

f When you perform maintenance or replacement of the parts, make sure to turn off the power and disconnect the power plug from the wall outlet. f Be sure to observe the procedure “Powering off the projector” ( x page 45) when performing power supply operation.

Maintenance

Outer Case

Wipe off dirt and dust using a soft dry cloth.

f If the dirt is persistent, soak the cloth with water and wring it thoroughly before wiping. Dry off the projector with a dry cloth.

f Do not use benzene, thinner, or rubbing alcohol, other solvents, household cleaners. Using them may cause deterioration of the outer case.

f When using chemical treated dusters, follow its instruction.

Lens front surface

Wipe the dirt and dust off the front surface of the lens with soft clean cloth.

f Do not use a cloth that has an abrasive surface or a cloth that is moist, oily, or covered with dust.

f Do not use excessive force when wiping the lens as it is fragile.

f Do not use benzene, thinner or rubbing alcohol, other solvents or household cleaners. Using them may cause deterioration of the lens.

Attention f The lens may be damaged if you hit with a hard object or wipe with excessive force. Please handle with care.

DO NOT WIPE THE LENS DURING OPERATION.

Cleaning the lens during operation may cause foreign objects adhering to the lens or bring damage to the lens surface.

Air filter unit

In the following cases, remove the air filter unit and check the clogging condition of the air filter. If the air filter is clogged, clean the air filter unit.

f If the time which is set in [PROJECTOR SETUP] menu → [FILTER COUNTER] → [TIMER] is reached, the message of “FILTER COUNTER has reached the set time.” that prompts to perform maintenance of the air filter unit is displayed on the projection screen. f The warning indicator <WARNING> lights red in the projection state.

f The warning indicator <WARNING> blinks red *1 in the standby state.

*1 The indicator flashes in the cycle: 2.0 seconds (light) → 2.0 seconds (off)

Attention f Make sure to turn off the power before performing maintenance on the air filter unit.

f Make sure that the projector is stable, and perform the maintenance in a safe place even if the air filter unit falls accidentally.

Removing the air filter unit

Hook

Air filter cover

Air filter cover

Air filter unit

Fig.1

122 - ENGLISH

Tabs

Hook

Fig.2

Chapter 6 Maintenance - Maintenance/replacement

1) Remove the air filter cover. (Fig.1) f Pull out the air filter cover from the hook of the projector while slightly pushing upward the tabs of the air filter cover and open it in the direction of the arrow in figure.

2) Remove the air filter unit.

f The air filter unit is fixed by the three hooks. Grasp the fibre of the air filter unit near to the cover side with one hook and then pull the air filter unit out from the air filter cover as arrow direction shown. (Fig.2) f After removing the air filter unit, remove foreign objects and dust from the air filter compartment and the projector’s intake vent if there are any.

Cleaning the air filter unit

Remove the air filter unit beforehand according to the previously described procedure in “Removing the air filter unit”.

1) Clean the air filter unit.

f Vacuum dirt and dust from the air filter unit.

f Do not wash the air filter unit.

Attaching the air filter unit

1) Attach the new air filter unit to the air filter cover.

f There is a distinction between the inside and outside of the air filter unit. Align the red mark on the air filter unit with the red mark on the air filter cover.

Air filter unit

Red mark Inside (Smooth fibre)

Outside (Cotton-like fibre)

Air filter cover f Insert the air filter unit to the side with the two hooks and then press the other side of the air filter unit into the cover side with one hook.

Hook

Air filter cover

Red mark Air filter unit

Hook

2) Attach the air filter cover to the projector.

f Perform Step 1) in “Removing the air filter unit” ( x page 122) in the reverse order.

f Make sure that the air filter cover is closed tightly.

Resetting the filter counter

Be sure to reset the filter counter after cleaning or replacing the air filter unit.

1) Connect the power plug, press the power < v / b > button.

2) Press the <MENU> button to display the main menu, then press as to select [PROJECTOR SETUP].

3) Press the <ENTER> button, press as to select [FILTER COUNTER].

4) Press the <ENTER> button, press as to select [FILTER COUNTER RESET].

ENGLISH - 123

Chapter 6 Maintenance - Maintenance/replacement

5) Press the <ENTER> button.

f [FILTER COUNTER RESET] confirmation is displayed.

6) Press as to select [OK], then press the <ENTER> button.

f The filter usage time is 0 after reset.

Attention f Do not disassemble the air filter unit.

f When attaching the air filter unit, make sure that the projector is stable, and work in an environment that is safe, even in the event of the air filter unit dropping.

f Make sure that the air filter unit is properly attached before using the projector. If it is not attached, the projector will suck in dirt and dust causing a malfunction.

Note f After cleaning or replacing the air filter, reset the filter counter. Otherwise, the actual filter usage time cannot be confirmed.

f Replace the air filter unit with the new optional Replacement Filter Unit (Model No.: ET-RFL300) if it is damaged or if the dirt does not come off even after cleaning.

Replacing the unit

Lamp unit

The lamp unit is a consumable component. Refer to “When to replace the lamp unit” ( x page 124) for details about the replacement cycle.

When purchasing the optional Replacement Lamp Unit (Model No.: ET-LAL510), consult your dealer.

Warning

Do not replace the lamp unit when it is hot. (Wait at least one hour after use.)

The inside of the cover can become very hot, take care to avoid burn injuries.

Notes on the replacement of the lamp unit f A Phillips screwdriver is necessary when replacing the lamp unit.

f Since the luminous lamp is made of glass, it may burst if dropped or hit with a hard object.

Handle with care.

f Do not disassemble or modify the lamp unit.

f When replacing the lamp unit, be sure to hold it by the handle because its surface is pointed and its shape is protruded.

f The lamp may rapture. Replace the lamp unit carefully so the glass fragments of the lamp do not scatter. While attaching the projector to the ceiling, do not work right under the lamp unit or do not conduct work while your face is near the lamp unit.

f The lamp contains mercury. When disposing of used lamp units, contact your local authorities or dealer for correct methods of disposal.

Attention f Panasonic Connect Co., Ltd. takes no responsibility for any damage or malfunction of the product resulting from use of lamp units which are not manufactured by Panasonic Connect Co., Ltd. Use only specified lamp units.

Note f The model numbers of accessories and optional accessories are subject to change without prior notice.

When to replace the lamp unit

The lamp unit is a consumable component. Since its brightness gradually decreases over time, it is necessary to replace the lamp unit regularly.

Please refer to [PROJECTOR SETUP] menu → [STATUS] → [RUNTIME] → [LAMP] about the usage time of lamp

( x page 77).

The estimated duration before replacement is 20 000 hours, but the lamp may go off before the time above mentioned has elapsed depending on individual lamp characteristics, usage conditions, and the installation environment. It is recommended that the Replacement lamp unit be prepared earlier.

The time which is displayed in [LAMP] is a total time when the real usage time in [NORMAL], [ECO] or [QUIET] is converted to the runtime in [ECO]. Please note that they are not displayed individually.

The displayed time in [LAMP] = “Lamp runtime of [NORMAL]” × 2 + “Lamp runtime of [ECO]”

+ “Lamp runtime of [QUIET]” × 2

The real usage time when the displayed time in [LAMP] is 20 000 hours means,

124 - ENGLISH

Chapter 6 Maintenance - Maintenance/replacement

When [Lamp control] is constantly set to [NORMAL] without switching to other modes = 10 000 hours

When [Lamp control] is constantly set to [ECO] without switching to other modes = 20 000 hours

When [Lamp control] is constantly set to [QUIET] without switching to other modes = 10 000 hours

If you continue to use the lamp unit when the displayed time in [LAMP] has reached 20 000 hours, the lamp turns off automatically at approximately 10 minutes after turning on the power, as it will cause malfunction of the projector.

The displayed time in [LAMP]

On-screen display <WARNING> indicator

19 700 hours ~

20 000 hours

Over 20 000 hours f The lamp replacement warning message of “REPLACE LAMP” is displayed for 30 seconds. If you press any button within 30 seconds, the warning message disappears.

f The countdown warning message of “REPLACE LAMP THE

PROJECTOR WILL SHUT DOWN AFTER ** MINUTES.” (“**” indicates the countdown time) is displayed for 10 minutes. The countdown warning message will disappear if you press any button within 10 minutes and will reappear on the screen after 1 minute.

f The countdown warning message will be displayed on the screen each time the input is switched or the projector power is turned on.

f The projector will power off automatically approximately 10 minutes after the lamp is turned on.

Off

Blinking red

(even in standby mode)

Note f The lamp replacement warning message will not be displayed in "Freeze" or "AV mute" status. f The usage period of 20 000 hours which is displayed in [PROJECTOR SETUP] menu → [STATUS] → [RUNTIME] → [LAMP] is a rough estimate and is not guaranteed.

Replacing the lamp unit

Attention f When the projector is mounted on a ceiling, do not work with your face close to the projector.

f Do not remove or loosen the screws other than specified ones when replacing the lamp unit.

f Make sure to attach the lamp unit and the lamp cover securely.

Lamp cover

Lamp unit fixing screws

Lamp cover fixing screw

Handles

1) Turn off the power by following the procedure in “Powering off the projector” ( x page 45). Remove the AC power plug from the wall outlet. f Wait at least one hour and make sure the lamp unit and surroundings are cool.

2) Use a Phillips screwdriver to loosen the lamp cover fixing screw (×1) until it turns freely and remove the lamp cover.

f Remove the lamp cover by pulling it slowly toward the direction of the arrow as the above figure shown.

3) Use a Phillips screwdriver to loosen the three lamp unit fixing screws (×3) until they turn freely.

4) Hold the used lamp unit by its handles, and pull it gently from the projector.

5) Insert the new lamp unit in correct direction. Tighten the three lamp unit fixing screws (×3) securely with a Phillips screwdriver.

f When you experience difficulty in installing the lamp unit, remove it and try again. If you use force to install the lamp unit, the connector may be damaged.

6) Attach the lamp cover. Tighten the lamp cover fixing screw (×1) securely with a Phillips screwdriver.

f Perform step 2) in reverse direction to attach the lamp cover.

ENGLISH - 125

Chapter 6 Maintenance - Maintenance/replacement

Resetting the lamp runtime

Be sure to reset the lamp runtime after replacing the lamp unit.

1) Connect the power plug, press the power < v / b > button.

2) While pressing the a button on the control panel, press and hold the w button on the control panel for eight seconds or more.

f The lamp runtime is reset and the display of the [PROJECTOR SETUP] menu → [STATUS] → [RUNTIME]

→ [LAMP] is [0 H].

f Please try step 2) again if the lamp runtime has not been reset.

Note f After replacing the lamp unit, reset the lamp runtime manually. Otherwise, the lamp runtime displayed in [PROJECTOR SETUP] menu →

[STATUS] → [RUNTIME] → [LAMP] may differ from the actual lamp runtime.

Air filter unit

When the dust remains after cleaning, the filter replacement timing has come.

The Replacement Filter Unit (Model No.: ET-RFL300) is an optional accessory. To purchase the product, consult your dealer.

Replacing the air filter unit

Attention f Make sure to turn off the power before replacing the air filter unit.

f Make sure that the projector is stable, and perform the maintenance in a safe place even if the air filter unit falls accidentally.

1) Remove the air filter cover. f Refer to “Removing the air filter unit” ( x page 122).

2) Remove the air filter unit.

f Refer to “Removing the air filter unit” ( x page 122).

3) Attach the optional Replacement Filter Unit (Model No.: ET-RFL300) to the air filter cover.

f Refer to “Attaching the air filter unit” ( x page 123).

4) Attach the air filter cover to the projector.

f Refer to “Attaching the air filter unit” ( x page 123).

5) Reset the filter counter.

f Refer to “Resetting the filter counter” ( x page 123).

Attention f When using the projector, be sure to attach the air filter unit. If it is not attached, the projector will suck in dirt and dust causing a malfunction.

f The air filter unit to be replaced should be an unused product.

Note f The time until the air filter is clogged varies greatly depending on the usage environment.

f When the projector is used without resetting the filter counter, the actual filter usage time will not be able to be confirmed.

126 - ENGLISH

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement

Table of contents