Pails. AIRLESSCO MP 400, MP 300

Add to My manuals
32 Pages

AIRLESSSCO MP 400 is a professional-grade airless paint sprayer designed for portable application of architectural paints and coatings. With a maximum working pressure of 3000 psi, it delivers exceptional power and precision for a variety of painting projects. Its rugged construction and durable components ensure long-lasting performance, while its user-friendly design makes it easy to operate and maintain.

advertisement

Pails. AIRLESSCO MP 400, MP 300 | Manualzz

Operation

10

Pails

Solvent and oil/based fluids: follow local code. Use only conductive metal pails, placed on a grounded surface such as concrete.

Do not place pail on a nonconductive surface such as paper or cardboard which interrupts grounding continuity.

Grounding a metal pail: connect a ground wire to the pail by clamping one end to pail and other end to a true earth ground such as a water pipe.

Pressure Relief Procedure

Follow the Pressure Relief Procedure whenever you see this symbol.

This equipment stays pressurized until pressure is manually relieved. To help prevent serious injury from pressurized fluid, such as skin injection, splashing fluid and moving parts, follow the Pressure

Relief Procedure when you stop spraying and before cleaning, checking, or servicing the equipment.

1. Engage the gun trigger lock. Refer to the separate instruction manual provided with gun for safety features and how to engage the trigger lock.

2. Turn the unit off.

3. Disengage the gun trigger lock and trigger the gun to relieve residual fluid pressure.

Hold metal part of the gun in contact with grounded metal pail. Use minimum pressure.

ti5851a

To maintain grounding continuity when flushing or relieving pressure: hold metal part of spray gun firmly to side of a grounded metal pail. Then trigger gun.

ti15989a

4. Re-engage gun trigger lock and turn Prime Valve to the open (priming) position.

Closed

(Pressure)

Open

(Priming) ti5310b ti17403a

NOTE: The valve handle can move both clockwise and counter clockwise and can face different directions.

NOTE: If you suspect the spray tip or hose is clogged or that pressure has not been fully relieved after following the steps above, VERY SLOWLY loosen tip guard retaining nut or hose end coupling to relieve pressure gradually, then loosen completely. Clear hose or tip obstruction.

332882A

advertisement

Related manuals

Frequently Answers and Questions

What are the warnings associated with using the AIRLESSSCO MP 400?
There are several warnings related to grounding, fire and explosion hazards, electric shock hazards, skin injection hazards, and equipment misuse hazards.
How do I properly ground the AIRLESSCO MP 400?
Connect the product to a properly grounded outlet with a grounding wire and plug. Use only 3-wire extension cords with grounding plugs and receptacles.
What precautions should I take to prevent fire and explosion hazards?
Keep the spray area well-ventilated, avoid flammable or combustible materials, ground all parts of the spray system, and do not smoke or operate spark-producing equipment in the spray area.
How can I avoid electric shock hazards?
Ensure the equipment is properly grounded, use only grounded electrical outlets and extension cords, and avoid exposing the unit to rain or storing it outdoors.
What should I do to prevent skin injection hazards?
Never aim the gun at or spray any person or animal, keep hands and body parts away from the discharge, always use the nozzle tip guard, and engage the trigger lock when not spraying.
How can I avoid equipment misuse hazards?
Wear appropriate safety gear, keep children away from the equipment, avoid overreaching or standing on unstable support, stay alert and focused, and never leave the unit energized or under pressure while unattended.
What is the maximum working pressure of the AIRLESSCO MP 400?
The maximum working pressure is 3000 psi (20.7 MPa, 207 bar).