Suction Assemblies. AIRLESSCO MP 400, MP 300

Add to My manuals
32 Pages

AIRLESSSCO MP 400 is a professional-grade airless paint sprayer designed for portable application of architectural paints and coatings. With a maximum working pressure of 3000 psi, it delivers exceptional power and precision for a variety of painting projects. Its rugged construction and durable components ensure long-lasting performance, while its user-friendly design makes it easy to operate and maintain.

advertisement

Suction Assemblies. AIRLESSCO MP 400, MP 300 | Manualzz

Parts

Gearbox Sleeve Bearing Replacement

Ref. Part

1

2

3

Description

331061 SLEEVE BEARING

331103 WASHER

331197 SCREW

Qty.

1

2

2

NOTE: When replacing item (1), cover outside of sleeve with 6 drops of Loctite 246 prior to inserting into cover assembly.

1 2 3 ti16059a

Suction Assemblies

Stand Chassis Hi-Boy Chassis (331284)

1

2

3

4

1

4

6

2

5 ti16061a

5 ti22330a

Ref. Part Description Qty.

1

2

331290 SUCTION HOSE ASSEMBLY 1

187651 INLET STRAINER 1

4* HOSE, 1/4 ID X 3/8 OD

5* 244035 DEFLECTOR, BARBED

40”

1

6* 114287 FITING, BARBED

* Sold in Kit 301349

1

Ref. Part

3

4

1

2

5

Description Qty.

301348 BYPASS HOSE ASSEMBLY 1

331034 SUCTION NUT 1

331292 SUCTION SEAT ASSEMBLY 1

331400 INLET TUBE 1

187190 INLET STRAINER 1

332882A 29

advertisement

Related manuals

Frequently Answers and Questions

What are the warnings associated with using the AIRLESSSCO MP 400?
There are several warnings related to grounding, fire and explosion hazards, electric shock hazards, skin injection hazards, and equipment misuse hazards.
How do I properly ground the AIRLESSCO MP 400?
Connect the product to a properly grounded outlet with a grounding wire and plug. Use only 3-wire extension cords with grounding plugs and receptacles.
What precautions should I take to prevent fire and explosion hazards?
Keep the spray area well-ventilated, avoid flammable or combustible materials, ground all parts of the spray system, and do not smoke or operate spark-producing equipment in the spray area.
How can I avoid electric shock hazards?
Ensure the equipment is properly grounded, use only grounded electrical outlets and extension cords, and avoid exposing the unit to rain or storing it outdoors.
What should I do to prevent skin injection hazards?
Never aim the gun at or spray any person or animal, keep hands and body parts away from the discharge, always use the nozzle tip guard, and engage the trigger lock when not spraying.
How can I avoid equipment misuse hazards?
Wear appropriate safety gear, keep children away from the equipment, avoid overreaching or standing on unstable support, stay alert and focused, and never leave the unit energized or under pressure while unattended.
What is the maximum working pressure of the AIRLESSCO MP 400?
The maximum working pressure is 3000 psi (20.7 MPa, 207 bar).