PARADOX Esprit 748 express + is a powerful and versatile security system that offers a wide range of features to protect your home or business. With its advanced technology and user-friendly design, the Esprit 748 express + is the perfect choice for anyone looking for a reliable and comprehensive security solution.

advertisement

Fire Circuit. PARADOX Esprit 748 express + | Manualzz

Installation

2.10.2 N.C. Contacts, Without EOL Resistor, With Tamper Recognition

If your security installation requires tamper recognition and you are using the ATZ feature, connect the detection devices and program the control panel as shown in figure 18. Do not use devices with normally open contacts, as this will cause the zone to remain open. This setup will communicate the status of each zone to the control panel (see figure 16), displaying open zones on the keypad. The control panel will also communicate any detected tampers (cuts) on the system as per

Tamper/Wire Fault Recognition Options (see section 10.7).

2.10.3 N.C. Contacts, With EOL Resistor, With Tamper & Wire Fault

Recognition (UL)

If your system requires tamper (cut) and wire fault (short) recognition, connect two detection devices to one input terminal with a 1K

?

end of line (EOL) resistor and program the control panel as shown in figure 19. Do not use devices with normally open contacts, this will cause the zone to remain open. This setup will communicate the status of each zone to the control panel (see figure 16), displaying open zones on the keypad. Any tampers (cuts) and/or wire fault (shorts) detected on the system are communicated as per Tamper/Wire

Fault Recognition Options (see section 10.7).

2.11 Fire Circuit

If your security installation requires the use of smoke detectors, define zone 3 as a

"24-hour" fire zone; please refer to section 7.5.

2.11.1 Standard Installation

Connect the smoke detectors to zone 3 as shown in figure 20. Note that a fire zone must use a 1K

?

EOL resistor. If there is a line short or if the smoke detector becomes active, whether the system is armed or disarmed, the control panel will generate an alarm (see Fire Alarm Output figure on page 30).

If the line is "open", the control panel will send a "fire loop" trouble report to the central station and trouble indicator, key [11], will appear in the keypad’s trouble display.

10

advertisement

Key Features

  • - Supports up to 8 keypads and 32 zones
  • - Features 4 programmable outputs (PGM) for controlling external devices
  • - Includes a built-in siren output for audible alerts
  • - Offers advanced technology zone (ATZ) connections for enhanced security.
  • - Supports fire alarm system integration for added protection against fire hazards.
  • - Provides serial output connectivity for easy integration with other devices.
  • - Delivers remote access and control via Espload software for convenient management.

Related manuals

Download PDF

advertisement

Table of contents