Fire Circuit. PARADOX Esprit 748 express +
Add to My manuals61 Pages
PARADOX Esprit 748 express + is a powerful and versatile security system that offers a wide range of features to protect your home or business. With its advanced technology and user-friendly design, the Esprit 748 express + is the perfect choice for anyone looking for a reliable and comprehensive security solution.
advertisement
Installation
2.10.2 N.C. Contacts, Without EOL Resistor, With Tamper Recognition
If your security installation requires tamper recognition and you are using the ATZ feature, connect the detection devices and program the control panel as shown in figure 18. Do not use devices with normally open contacts, as this will cause the zone to remain open. This setup will communicate the status of each zone to the control panel (see figure 16), displaying open zones on the keypad. The control panel will also communicate any detected tampers (cuts) on the system as per
Tamper/Wire Fault Recognition Options (see section 10.7).
2.10.3 N.C. Contacts, With EOL Resistor, With Tamper & Wire Fault
Recognition (UL)
If your system requires tamper (cut) and wire fault (short) recognition, connect two detection devices to one input terminal with a 1K
?
end of line (EOL) resistor and program the control panel as shown in figure 19. Do not use devices with normally open contacts, this will cause the zone to remain open. This setup will communicate the status of each zone to the control panel (see figure 16), displaying open zones on the keypad. Any tampers (cuts) and/or wire fault (shorts) detected on the system are communicated as per Tamper/Wire
Fault Recognition Options (see section 10.7).
2.11 Fire Circuit
If your security installation requires the use of smoke detectors, define zone 3 as a
"24-hour" fire zone; please refer to section 7.5.
2.11.1 Standard Installation
Connect the smoke detectors to zone 3 as shown in figure 20. Note that a fire zone must use a 1K
?
EOL resistor. If there is a line short or if the smoke detector becomes active, whether the system is armed or disarmed, the control panel will generate an alarm (see Fire Alarm Output figure on page 30).
If the line is "open", the control panel will send a "fire loop" trouble report to the central station and trouble indicator, key [11], will appear in the keypad’s trouble display.
10
advertisement
Key Features
- - Supports up to 8 keypads and 32 zones
- - Features 4 programmable outputs (PGM) for controlling external devices
- - Includes a built-in siren output for audible alerts
- - Offers advanced technology zone (ATZ) connections for enhanced security.
- - Supports fire alarm system integration for added protection against fire hazards.
- - Provides serial output connectivity for easy integration with other devices.
- - Delivers remote access and control via Espload software for convenient management.
Related manuals
advertisement
Table of contents
- 5 About This Manual
- 5 Features
- 6 Specifications
- 6 Accessories & Keypads
- 6 About Paradox
- 7 Location & Mounting
- 7 Earth Ground
- 7 Power
- 8 Telephone Line Connection
- 9 Bell/Siren Output
- 9 Programmable Outputs (PGM)
- 9 Keypad & Keyswitch Connections
- 9 Keypad Zone Connections
- 11 Single Zone Input Terminal Connections
- 13 Advanced Technology Zone (ATZ) Connections
- 14 Fire Circuit
- 15 Serial Output Connector
- 16 Installer Code
- 16 Master & User Codes
- 16 User / Access Code Length
- 16 Duress
- 16 Installer Lock
- 17 Espload Software
- 17 Keypad
- 20 Panel Answer Options
- 21 Panel Identifier
- 21 PC Password
- 21 Computer Telephone Number
- 21 Call Espload
- 21 Answer Espload
- 22 Cancel Communication
- 22 Call Back
- 22 Automatic Event Buffer Transmission
- 24 Reporting Options
- 25 Central Station Telephone Number
- 26 System Account Codes
- 26 Communicator Formats
- 28 Reporting Event Codes
- 30 Auto Test Report
- 30 Manual Test Report
- 30 Power Failure Report Delay
- 30 Recent Close Delay
- 31 Report Zone Restore Options
- 31 Report Code Disarming Options
- 33 Zone Speed
- 33 Advanced Technology Zoning (ATZ)
- 33 Intellizones
- 34 Silent Zones
- 34 "24 Hour" & Fire Zones
- 34 Instant Zones
- 34 Follow Zones
- 35 Entry Delay
- 35 Partitioning
- 36 Bypass Enabled Zones
- 36 EOL Zones (Enabled/Disabled)
- 37 Keypad Zone 1 Supervision
- 37 Keypad Zone 2 Supervision
- 39 "Timed" Auto Arming
- 39 "No Movement" Auto Arming
- 40 "One-Key" Regular Arming
- 40 "One-Key" Stay/System A Arming
- 40 Arming using a keyswitch
- 40 Bell Squawk
- 41 Exit Delay
- 41 Beep on Exit delay
- 41 Alarm Transmission Delay
- 41 Silent Zones & Silent Panics Option
- 41 Bell Cut-Off Time
- 42 Code Priority
- 43 PGM Types
- 44 PGM Timer Setting
- 44 PGM Options
- 45 Telephone Line Monitoring (TLM)
- 45 Dialing Options
- 45 Dialing Pulse Rates
- 45 Keypad Panic Options
- 46 Panel Time
- 46 Time Correction
- 47 Tamper/Wire Fault Recognition Options
- 47 Tamper Bypass Options
- 47 Installer Test Mode
- 48 Exclude Power Failure From Trouble Display
- 48 Audible Trouble Warning
- 48 Power Down Reset
- 49 Programming Master & User Codes
- 49 Regular Arming
- 50 Away Arming
- 50 Stay Arming
- 51 Arming/Disarming Partitions
- 52 System Disarming
- 52 Alarm Memory
- 52 Keyswitch or Pushbutton Arming/Disarming
- 52 Manual Zone Bypassing
- 53 Bypass Recall
- 53 Keypad Chime Zones
- 53 Trouble Display Monitoring
- 55 Key Access Programming