PARADOX Esprit 748 express + is a powerful and versatile security system that offers a wide range of features to protect your home or business. With its advanced technology and user-friendly design, the Esprit 748 express + is the perfect choice for anyone looking for a reliable and comprehensive security solution.

advertisement

Auto Test Report. PARADOX Esprit 748 express + | Manualzz

Event Reporting

518 Partial Arming: Whenever the system is "Away" armed, "Stay" armed, or armed while one or more zones are bypassed.

519 Recent Close: An alarm occurs shortly after the system has been armed, refer to

Recent Close Delay in section 6.10.

520 Duress: The Duress feature is enabled (see section 3.4) and a User disarms the system using the User Code #48.

524 Log-In (Espload): Espload software is used to communicate with the Control Panel.

525 Program Change: The installer code is used to enter the programming mode

521 to 523 - Reserved for Future Use

526 to 527 - Reserved for Future Use

6.7

Auto Test Report

Decimal Programming

?

Addresses 046-048

Default: Auto Test Report Disabled

The report code programmed at address 512 will be reported to the central station after the number of days programmed at address 046 and the time programmed at address 047 (hours) and 048

(minutes) has elapsed. To disable this feature, program 000 at address 046. Also note that if

[2

ND

][2

ND

] is programmed at address 512 nothing will be reported.

[ ENTER ] + Installer Code + [10] [4] [6] + 3 digits (days) + [10] [4] [7] + 3 digits (hours) + [10] [4] [8]

+ 3 digits (minutes) + [

ENTER

]

6.8

Manual Test Report

Key Access Programming

?

key [

BYP

]

Activating the manual test report will send the Event Code programmed at address 512 to the

Central Station.

[

ENTER

] + (Installer, Master, or User 1 Code) + [

BYP

] + [

ENTER

]

6.9

Power Failure Report Delay

Decimal Programming

?

Addresses 054

Default: 30 minutes

After a power failure, the control panel will delay transmission of the event code programmed at address 499 by the period programmed at this address (001 to 255 minutes).

[

ENTER

] + Installer Code + [10] [5] [4] + 3-digit decimal value (001-255) + [

ENTER

]

6.10 Recent Close Delay

Decimal Programming

?

Addresses 060

Default: Recent Close Delay Disabled

The system will transmit the recent close event code programmed at address 519 if after arming the system, an alarm occurs within the period programmed at this address (001 to 255 minutes).

Program 000 into address 060 to disable this feature.

[ ENTER ] + Installer Code + [10] [6] [10] + 3-digit decimal value (001-255) + [ ENTER ]

26

advertisement

Key Features

  • - Supports up to 8 keypads and 32 zones
  • - Features 4 programmable outputs (PGM) for controlling external devices
  • - Includes a built-in siren output for audible alerts
  • - Offers advanced technology zone (ATZ) connections for enhanced security.
  • - Supports fire alarm system integration for added protection against fire hazards.
  • - Provides serial output connectivity for easy integration with other devices.
  • - Delivers remote access and control via Espload software for convenient management.