PARADOX Esprit 748 express + is a powerful and versatile security system that offers a wide range of features to protect your home or business. With its advanced technology and user-friendly design, the Esprit 748 express + is the perfect choice for anyone looking for a reliable and comprehensive security solution.

advertisement

Entry Delay. PARADOX Esprit 748 express + | Manualzz

Zone Definitions

Zones. Follow zones function as follows:

?

If a follow zone opens and no entry delay zones have been triggered; the control panel will immediately generate an alarm after the zone speed has elapsed.

?

If a follow zone opens during another zone's entry delay period, the control panel will wait until the end of the entry delay period before generating an alarm.

?

If a follow zone opens when more than one entry delay zone has been triggered, the panel will wait until the end of the entry delay zone that opened first before generating an alarm.

7.8

Entry Delay 1

Decimal Programming

?

Address 050

Default: 45 seconds

Any zone that has not been identified as either Instant Zones, Follow Zones, Entry Delay 2, or "24

Hour" & Fire Zones (see above) will automatically default to Delay 1. You can program the Delay 1 period between 001 and 255 seconds into address 050. If a zone defined as Delay 1 opens in an armed system, the control panel will wait the pre-programmed period before generating an alarm.

This provides the users the time required to disarm the system when entering the protected area.

[

ENTER

] + Installer Code + [10] [5] [10] + 3-digit decimal value (001-255) + [

ENTER

]

7.9

Entry Delay 2

Feature Select Programming

?

Addresses 112 & 114, keys [1] to [12]

Using the " Feature Select Programming Method ", select which zones will be defined as Entry

Delay 2 Zones. If a zone defined as Delay 2 opens in an armed system, the control panel will wait the Entry Time Delay 2 (see below) period before generating an alarm. This provides the users the time required to disarm the system when entering the protected area.

7.9.1 Entry Time Delay 2

Decimal Programming

?

Address 051

Default: 45 seconds

This applies to all zones defined as Delay 2 (see Entry Delay 2 above). You can program the

Delay 2 between 001 and 255 seconds.

[

ENTER

] + Installer Code + [10] [5] [1] + 3-digit decimal value (001-255) + [

ENTER

]

7.10 Partitioning

Feature Select Programming

?

Address 086, key [8]

This feature divides the alarm system into two distinct systems, identified as "System A" and

"System B". You can assign each zone to System A, System B, both systems, or neither system.

Partitioning works as follows:

?

Zones assigned to System A, will arm/disarm when the system is "System A Armed/Disarmed".

?

Zones assigned to System B, will arm/disarm when the system is "System B Armed/Disarmed".

?

Zones assigned to both systems ("dual area") will arm when the system is either "System A

Armed", "System B Armed" or when both systems are armed and will disarm only when both systems disarm.

?

Zones not identified to any system ("common area") will arm only when the system is both

"System A Armed" and "System B Armed" and will only disarm when at least one of the two systems disarms.

31

advertisement

Key Features

  • - Supports up to 8 keypads and 32 zones
  • - Features 4 programmable outputs (PGM) for controlling external devices
  • - Includes a built-in siren output for audible alerts
  • - Offers advanced technology zone (ATZ) connections for enhanced security.
  • - Supports fire alarm system integration for added protection against fire hazards.
  • - Provides serial output connectivity for easy integration with other devices.
  • - Delivers remote access and control via Espload software for convenient management.

Related manuals

Download PDF

advertisement

Table of contents