PARADOX Esprit 748 express + is a powerful and versatile security system that offers a wide range of features to protect your home or business. With its advanced technology and user-friendly design, the Esprit 748 express + is the perfect choice for anyone looking for a reliable and comprehensive security solution.

advertisement

PGM Types. PARADOX Esprit 748 express + | Manualzz

PGM (Programmable Output)

PGM (PROGRAMMABLE OUTPUT)

We strongly suggest using of the Espload software to program the PGM.s

9.1

PGM Types

Streamline - Sections 09

?

Hexa Programming - Address 039

These control panels have two programmable outputs (PGMs). When a PGM closes, a ground is supplied to activate any device or relay connected to it, providing up to a maximum of 50mA (UL

30mA). When a PGM opens, the circuit is opened from ground, therefore not providing any power to devices connected to it. To program a PGM you must define the PGM state (normally open or normally closed), the timing (regular or timed) and you must define the type of logic ("OR", "AND", "EQUAL").

To do so, use table 7 to determine which hexa digit to program into address 039, where the first hexa digit programmed corresponds to PGM1 and the second hexa digit corresponds to PGM2.

?

Regular N.O./N.C.

A triggered PGM will switch to its opposite state (i.e. closed to open or opened to closed). The

PGM will return to its original state once the event(s) that triggered it have terminated.

?

Timed N.O./N.C.

A triggered PGM will switch to its opposite state (i.e. closed to open or opened to closed). The

PGM will remain in its opposite state for the period programmed at address 056 (see section

9.2). If the PGM is triggered again before the period has elapsed, the PGM will remain in its opposite state and reset the timer.

?

"OR" Logic

Will trigger a PGM when at least one event occurs from a specific group of events (e.g. key [1] and/or key [2] is pressed on the keypad).

?

"AND" Logic

The "AND" logic will trigger a PGM when all events, or more, occur from a specific group of events (e.g. Keys [1] and [2] are pressed simultaneously. Note that pressing those two keys in conjunction with any other key will also trigger the PGM).

?

"EQUAL" Logic

The "EQUAL" logic will trigger a PGM only when the events from a specific group of events occur (e.g. Key [1] and [2] are pressed. Note the PGM will only trigger when pressing keys [1] and [2] simultaneously, if any other key is pressed at the same time (e.g. [1], [2] & [3]) the PGM will not trigger).

[

ENTER

] + Installer Code + [10] [3] [9] + first digit (PGM1) + second digit (PGM2) + [

ENTER

]

39

advertisement

Key Features

  • - Supports up to 8 keypads and 32 zones
  • - Features 4 programmable outputs (PGM) for controlling external devices
  • - Includes a built-in siren output for audible alerts
  • - Offers advanced technology zone (ATZ) connections for enhanced security.
  • - Supports fire alarm system integration for added protection against fire hazards.
  • - Provides serial output connectivity for easy integration with other devices.
  • - Delivers remote access and control via Espload software for convenient management.