PARADOX Esprit 748 express + is a powerful and versatile security system that offers a wide range of features to protect your home or business. With its advanced technology and user-friendly design, the Esprit 748 express + is the perfect choice for anyone looking for a reliable and comprehensive security solution.

advertisement

PGM Timer Setting. PARADOX Esprit 748 express + | Manualzz

PGM (Programmable Output)

9.2

PGM Timer Setting

Decimal Programming

?

Address 056

Default: 5 seconds

You can program the PGM Timer from 1 to 127 seconds or 1 to 127 minutes. The PGM Timer applies to both PGMs. To determine the 3-digit decimal value, do the following:

?

To program seconds, the required time is respective to the decimal value

1 second = 001, 55 seconds = 055, 127 seconds = 127.

?

To program the minutes add the required minutes to 128:

5 minutes: 128 + 5 = 133

127 minutes: 128 +127 = 255

[

ENTER

] + Installer Code + [10] [5] [6] + 3-digit decimal value (001-255) + [

ENTER

]

9.3

PGM Options

Streamline - Section 10

?

Hexa Programming - Addresses 040 to 043

The PGM options define which sequence of events will trigger the PGM. The PGM options are virtually endless. Therefore, to list them in the manual is impractical. Table 8, contains a list of the most commonly used PGM options with the required 2-digit data for each address. If other options are required, you can fax your requests to Paradox Technical Support, you can visit our web site at http://www.paradox.ca. or the 2-digit data can be derived using the Espload Software as follows:

1) From the "Main Menu" select Accounts

2) Select a current Account or create a new one

3) Press the

?

key until page 9 appears

4) Using the arrow keys and space bar select the PGM options, state, logic and type for the PGM

5) Press the

?

key to view the "Hexadecimal Mode". This mode will display the 2-digit data for addresses 039 to 043.

6) Record these numbers and program them into the control panel or use the Espload Software to download the data directly to the control panel.

If you do not have a copy of the Espload Software, you can obtain a FREE copy from your local

Paradox distributor.

40

advertisement

Key Features

  • - Supports up to 8 keypads and 32 zones
  • - Features 4 programmable outputs (PGM) for controlling external devices
  • - Includes a built-in siren output for audible alerts
  • - Offers advanced technology zone (ATZ) connections for enhanced security.
  • - Supports fire alarm system integration for added protection against fire hazards.
  • - Provides serial output connectivity for easy integration with other devices.
  • - Delivers remote access and control via Espload software for convenient management.

Related manuals

Download PDF

advertisement

Table of contents