PARADOX Esprit 748 express + is a powerful and versatile security system that offers a wide range of features to protect your home or business. With its advanced technology and user-friendly design, the Esprit 748 express + is the perfect choice for anyone looking for a reliable and comprehensive security solution.

advertisement

Tamper/Wire Fault Recognition Options. PARADOX Esprit 748 express + | Manualzz

Other Options

10.7 Tamper/Wire Fault Recognition Options

Feature Select Programming

?

Address 088, keys [10] to [11]

If the control panel detects an open or a short on a zone when the system is armed, regardless of the tamper/wire settings it will always generate an alarm and trouble indicator (key [9]). Alarms will be audible or silent depending on individual zone definitions. If an open or short occurs on a disarmed system, the control panel will generate an incident depending on the following settings:

"Tamper/wire" disabled

Tamper/wiring failure recognition is disabled. Not permitted on UL listed systems.

"Trouble" enabled

Tamper/wiring failure will generate a trouble indicator (key [9]) and a trouble report code (see

Tamper/Trouble Codes in section 6.6.6.) when the system is disarmed.

"Silent alarm" enabled

Tamper/wiring failure will generate a trouble indicator (key [9]), a trouble report code (see

Tamper/Trouble Codes in section 6.6.6.) and a silent alarm (no bells/sirens)

"Audible alarm" enabled

Tamper/wiring failure will generate a trouble indicator (key [9]), a trouble report code (see

Tamper/Trouble Codes in section 6.6.6.) and an audible alarm.

Exception! When the zone definition is "24 hour", the tamper definition follows the audible/silent alarm definition of the "24 hour" zone.

10.8 Tamper Bypass Options

Feature Select Programming

?

Address 090, key [6]

With this option enabled, the control panel will not generate an alarm if a tamper is detected on a bypassed zone while the system is armed. With this option disabled, the control panel will generate an alarm if a tamper is detected on a bypassed zone while the system is armed.

Key [6] "Off": Arm the system if Tamper on Bypassed Zone

Key [6] "On": Do not arm the system if Tamper on Bypassed Zone

[

ENTER

] + Installer Code + [10] [9] [10] + [6] On/Off + [

ENTER

]

10.9 Installer Test Mode

Key Access Programming

?

key [8]

The "Test Mode" will allow you to perform walk tests where the bell or siren will squawk, to indicate opened zones. To enter or exit the control panel "Test Mode" press:

[

ENTER

] + Installer Code + [8] to enable; press [8] again to disable

43

advertisement

Key Features

  • - Supports up to 8 keypads and 32 zones
  • - Features 4 programmable outputs (PGM) for controlling external devices
  • - Includes a built-in siren output for audible alerts
  • - Offers advanced technology zone (ATZ) connections for enhanced security.
  • - Supports fire alarm system integration for added protection against fire hazards.
  • - Provides serial output connectivity for easy integration with other devices.
  • - Delivers remote access and control via Espload software for convenient management.

Related manuals

Download PDF

advertisement

Table of contents