PARADOX Esprit 748 express + is a powerful and versatile security system that offers a wide range of features to protect your home or business. With its advanced technology and user-friendly design, the Esprit 748 express + is the perfect choice for anyone looking for a reliable and comprehensive security solution.

advertisement

Programming Master & User Codes. PARADOX Esprit 748 express + | Manualzz

User/Keypad Functions

USER/KEYPAD FUNCTIONS

The innovative Esprit keypads take a new approach to security features and functions. Each numeral from 1 to 12 on the keypad respectively represents each zone from 1 to 12 on the control panel. When the [2

ND

] key flashes, press the [2

ND

] key to view zones 13 to 24, where keys [1] to

[12] represent zones 13-24 respectively. When the zone light is "off", the status in the protected zone is normal. If the zone light is "on", this means the zone is open. An LCD keypad will display the open zone numbers on the screen.

The green "ready" indicator on the keypad will illuminate when the status of all the zones is normal

(zones are closed). Therefore, all protected windows and doors must be closed and motion detectors must not detect any movement except those zones that have been bypassed.

Confirmation Beep: an intermittent series of beeps ("

BEEP

-

BEEP

-

BEEP

") indicates a successful keypad entry or system operation.

End/Rejection Beep: one long tone (" BEEEEEEEP ") indicates incorrect keypad entry or unsuccessful system operation.

11.1 Programming Master & User Codes

The Esprit control panels have one Master (00) code and up to 48 User (01-48) codes. The default Master code is

474747

. The Master code can arm the system using any arming method, can create/modify user codes and can perform Key Access Programming (see section 10.13). The

User 1 code can create/modify access codes and perform key access programming. The access code consists of either 4 or 6-digits and each digit can be any value from 0 to 9.

Note: do not enter [2

ND

] when programming the master code as this will invalidate the master code.

[ ENTER ] + Master or User 1 Code + 2-digit code number (00-48) + 4 or 6-digit access code + [ ENTER ]

11.2 Regular Arming

This method, commonly used for day-to-day arming, will arm all the zones in the system. To do so, the keypad's green "

READY

" light must be illuminated, indicating that all zones are closed. All doors and windows must be closed, and there can be no movement in areas monitored by motion detectors. Once the " READY " light is on, a valid user access code must be entered. If a mistake is made entering the code or if the "

READY

" indicator is not on when the code was entered, the keypad will emit a "rejection beep" (

BEEEEEEEP

).

When the correct user access code is entered, the keypad will emit a "confirmation beep" (

BEEP

-

BEEP

-

BEEP

) and the red "

ARM

" indicator will illuminate. The "

READY

" light will flash and the keypad will

"beep" during the exit delay period (see section 8.7). During the final 10 seconds of the exit delay, the keypad will "beep" and the "

READY

" indicator will flash at a faster rate. At the end of the exit delay, the keypad will emit a "confirmation beep", the green "

READY

" indicator will extinguish and the red " ARM " indicator will remain illuminated to indicate that the system is armed.

11.2.1 "One-Key" Regular Arming

To use this feature, enable the "One-Key" Regular Arming option (see section 8.3). When the green "

READY

" light is on, pressing and holding the [10] key for 2 seconds will arm all zones in the system. This feature can be used to allow specific individuals like service personnel (i.e.

cleaners, maintenance) to arm the system when leaving the protected area, without giving

45

advertisement

Key Features

  • - Supports up to 8 keypads and 32 zones
  • - Features 4 programmable outputs (PGM) for controlling external devices
  • - Includes a built-in siren output for audible alerts
  • - Offers advanced technology zone (ATZ) connections for enhanced security.
  • - Supports fire alarm system integration for added protection against fire hazards.
  • - Provides serial output connectivity for easy integration with other devices.
  • - Delivers remote access and control via Espload software for convenient management.