INSTALLATION INSTRUCTIONS. KitchenAid KMCS522PPS

Add to My manuals
12 Pages

advertisement

INSTALLATION INSTRUCTIONS. KitchenAid KMCS522PPS | Manualzz

INSTALLATION INSTRUCTIONS

Tools and Parts

Tools Needed

Gather the required tools and parts before starting installation.

Read and follow the instructions provided with any tools listed here.

Measuring tape

Pencil

Phillips screwdriver

Drill

7/64" drill bit

Parts Supplied (not shown to scale

Rear duct Bottom duct Rails (2)

Trim kit frame

Required Cutout Dimensions

For minimum depth requirements, see chart.

6"

(15.2cm)

13 /

16

"

(2.14 cm)

17 1 /

8

"

(43.5cm) min

17 3 / "

(43.7cm) max

23 1 /

8

"

(58.7 cm)

A

3 15 /

16

"

(10cm)

13 /

16

"

(2.14 cm)

B

D C

A. Trim kit frame overhang

B. Cutout for lower oven

C. Recommended region for receptacle location (no less than 6" [15.2 cm] to the right of cutout centerline)

D. Cutout centerline

19# screw

M4*10

8+3 extra

93# screw

ST3*25 ( 4+2 extra )

123# screw

ST4*16

7+3 extra

Location Requirements

The microwave oven may be installed over a built-in oven. If installing over a built-in oven, make sure there is a minimum of

3 15 /

16

" (10cm) between the top of the lower oven cutout and the microwave oven cutout floor.

The microwave oven may also be installed in a cabinet by itself

(without a built-in oven below). For best usability, we recommend a minimum distance of 36 1 /

16

" (91.6 cm) from the floor to the cutout floor.

Make sure the surrounding cabinetry has clearance to open and close freely. Allow a clearance of at least 2" (5 cm) below the cutout floor (3 15 /

16

" [10 cm] for installation above a built-in oven), and a clearance of at least 2" (5 cm) above the cutout opening.

A

2"

(5 cm)

2"

(5 cm)

B B

2"

(5 cm)

3 15 /

16

"

(10cm)

C

D

E

36 1 /

16

"

(91.6 cm)

A. Upper cabinet

B. Microwave oven cutout

C. Lower oven cutout

D. Lower cabinets

E. Floor

Receptacle Location Minimum Depth

Within recommended region

21 9 /

16

" (54.8 cm) with flush receptacle;

23 9 /

16

" (59.8cm) with non-flush receptacle

Outside recommended region

23 9 /

16

" (59.8 cm) with flush receptacle;

25 9 /

16

" (64.9 cm) with non-flush receptacle

NOTES:

■ Depth requirements depend upon receptacle and its location within or outside of recommended region. See illustration and chart above.

■ Height dimension is critical: 17 1 /

8

" (43.5 cm) minimum,17 3 /

16

"

(43.7 cm) minimum.

■ Width measurement has ±1/16" (2 mm) tolerance.

■ 3 15 /

16

" (10 cm) minimum dimension is from lower oven cutout ceiling to microwave oven cutout floor.

■ Trim kit frame extends 13 cutout opening.

⁄₁₆ " (2.14 cm) above and below the

18 13 /

16

"

(47.78cm)

26 13 /

16

" (68.08cm)* *

29 3 /

4

" (75.48cm)** *

22 7 /

8

"

(55.59 cm )

2 5

16

"( 5.89cm) * *

3 3 /

4

"(9.59cm)**

3 3 /

8

" (8.64 cm)

3 9 /

16

"(9.09 cm)

11 9 /

16

"

(29.38 cm )

1 1

8 (2.92 cm)

*27" (68.6 cm) trim kit

**30" (76.2 cm) trim kit

2