Electrical Data. Trane Fan-Powered Low-Height Parallel

Add to My manuals
234 Pages

advertisement

Electrical Data. Trane Fan-Powered Low-Height Parallel | Manualzz

Electrical Data

Parallel Fan-Powered Terminal Units

Table 67. PSC motor units—electric coil kW guidelines – minimum to maximum (VPEF)

Single-Phase Voltage Three-Phase Voltage

Fan Size Stages

02SQ

1

2

03SQ

04SQ

05SQ

06SQ

07SQ

1

2

1

2

1

2

1

2

1

2

120V

0.5-5.0

0.5-5.0

0.5-5.0

0.5-5.0

0.5-4.5

0.5-4.5

0.5-4.5

0.5-4.5

-

-

-

-

208V

0.5-6.0

0.5-6.0

0.5-9.0

0.5-9.0

0.5-8.0

0.5-8.0

0.5-8.0

0.5-8.0

0.5-9.0

0.5-9.0

0.5-8.0

0.5-8.0

240V

0.5-6.0

0.5-6.0

0.5-10.0

0.5-10.0

0.5-10.0

0.5-10.0

0.5-9.0

0.5-9.0

-

-

-

-

277V

0.5-6.0

1.0-6.0

0.5-11.0

1.0-11.0

0.5-12.0

1.0-12.0

0.5-12.0

1.0-12.

0.5-12.0

1.0-12.0

0.5-11.0

1.0-11.0

347V

0.5-6.0

1.0-6.0

0.5-11.0

1.0-11.0

0.5-14.0

1.0-14.0

0.5-15.0

1.0-15.0

0.5-15.0

1.0-15.0

0.5-15.0

1.0-15.0

480V

0.5-6.0

1.0-6.0

0.5-11.0

1.0-11.0

0.5-14.0

1.0-14.0

0.5-18.0

1.0-18.0

0.5-16.0

1.0-16.0

0.5-20.0

1.0-20.0

208V

0.5-6.0

1.0-6.0

0.5-11.0

1.0-11.0

0.5-14.0

1.0-14.0

0.5-14.0

1.0-14.0

0.5-15.0

1.0-15.0

0.5-14.0

1.0-14.0

480V

1.0-6.0

2.0-6.0

1.0-11.0

2.0-11.0

1.0-14.0

2.0-14.0

1.0-18.0

2.0-18.0

1.0-16.0

2.0-16.0

1.0-20.0

2.0-20.0

600V

1.5-6.0

3.0-6.0

1.5-11.0

3.0-11.0

1.5-14.0

3.0-14.0

1.5-18.0

3.0-18.0

1.5-16.0

3.0-16.0

1.5-20.0

3.0-20.0

380V/

50Hz

1.0-6.0

1.5-6.0

1.0-11.0

1.5-11.0

1.0-14.0

1.5-14.0

1.0-18.0

1.5-18.0

1.0-16.0

1.5-16.0

1.0-20.0

1.5-20.0

Table 68. ECM units—electric coil kW guidelines – minimum to maximum (VPEF)

Single-Phase Voltage Three-Phase Voltage

Fan Size Stages

03SQ

04SQ

05SQ

06SQ

1

2

1

2

1

2

1

2

120V

0.5-4.5

0.5-4.5

0.5-4.5

0.5-4.5

0.5-4.0

0.5-4.0

0.5-4.0

0.5-4.0

208V

0.5-8.0

0.5-8.0

0.5-8.0

0.5-8.0

0.5-7.0

0.5-7.0

0.5-7.0

0.5-7.0

240V

0.5-10.0

0.5-10.0

0.5-9.0

0.5-9.0

0.5-8.0

0.5-8.0

0.5-8.0

0.5-8.0

277V

0.5-11.0

1.0-11.0

0.5-12.0

1.0-12.0

0.5-11.0

1.0-11.0

0.5-11.0

1.0-11.0

347V

-

-

-

-

-

-

-

-

480V

0.5-11.0

1.0-11.0

0.5-14.0

1.0-14.0

0.5-18.0

1.0-18.0

0.5-16.0

1.0-16.0

208V

0.5-11.0

1.0-11.0

0.5-14.0

1.0-14.0

0.5-12.0

1.0-12.0

0.5-12.0

1.0-12.0

480V

1.0-11.0

2.0-11.0

1.0-14.0

2.0-14.0

1.0-18.0

2.0-18.0

1.0-16.0

2.0-16.0

600V

-

-

-

-

-

-

-

-

Notes:

1. Coils available with 24-VAC magnetic or mercury contactors, load carrying P.E. switches, and P.E. switch with magnetic or mercury contactors.

2. Available kW increments are by 0.5 from 0.5 kW to 8.0 kW, by 1.0 kW from 9.0 to 18.0 kW, and by 2.0 kW from 18.0 to 20.0 kW.

3. Each stage will be equal in kW output.

4. All heaters contain an auto reset thermal cutout and a manual reset cutout.

5. See section

“Formulas,” p. 73

for formulas used to calculate the current amp draw for the heater elements.

6. Recommended coil temperature rise = 20° to 30°F (-7° to -1°C). Maximum temperature rise = 55°F (12°C).

7. Heaters should not operate at cfms below the nameplate minimum.

380V/

50Hz

-

-

-

-

-

-

-

-

Table 69. Fan electrical performance (PSC)

Fan Size

02SQ

03SQ

04SQ

05SQ

06SQ

07SQ

HP

1/8

1/3

1/3

1/2

1/2

1

115 VAC

1.6

4.3

5.5

6.7

-

-

Maximum Fan Motor Amperage (FLA)

208 VAC

-

-

-

-

4.6

6.6

277 VAC

0.7

1.6

2.0

2.4

3.8

4.7

VAV-PRC012-EN 59

Electrical Data

Table 69. Fan electrical performance (PSC)

Notes:

1. Electric Heat Units - Units with fan sizes 02SQ to 05SQ and a primary voltage of 208/60/1, 208/60/3, or 240/60/1 have 115/60/1 VAC fan motors. Fan sizes 06SQ and 07SQ with the same voltages, have 208/60/1 VAC motors.

2. Electric Heat Units - Units with primary voltage of 277/60/1, 480/60/1 or 480/60/3 use 277 VAC fan motors.

3. Electric Heat Units - Units with primary voltage of 347/60/1 or 575/60/3 use 347 VAC fan motors.

4. With 380/50/3 and 230/50/1, use 230/50 motors.

Table 70. Fan electrical performance (ECM)

Fan Size

03SQ

04SQ

05SQ

06SQ

HP

1/3

1/2

1

1

Maximum Fan Motor Amperage (FLA)

115 VAC 277 VAC

4.5

6.5

10.1

9.5

Notes:

1. Electric heat units—units with primary voltages of 208/60/1, 208/60/3, or 240/60/1 have 115-VAC fan motors.

2. Electric heat units—units with primary voltages of 277/60/1, 480/60/1, or 480/60/3 have 277-VAC fan motors.

3. 347/60/1 and 230/50/1 voltage motors not available with ECMs.

2.4

3.5

5.4

5.1

Table 71. Minimum unit electric heat Cfm guidelines (PSC)

Unit kW

11

12

13

14

15

16

6.5

7

7.5

8

9

10

17

18

20

3.5

4

4.5

5

5.5

6

0.5

1

1.5

2

2.5

3

02SQ

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

201

229

257

285

312

340

118

118

118

118

146

174

03SQ

630

-

-

-

-

-

375

400

430

460

515

575

-

-

-

200

230

260

290

315

350

200

200

200

200

200

200

04SQ

-

-

-

630

690

745

810

-

-

375

400

430

460

515

575

315

315

315

315

315

350

315

315

315

315

315

315

Cfm

05SQ

630

690

745

810

860

920

375

400

430

460

515

575

973

1030

-

350

350

350

350

350

350

350

350

350

350

350

350

06SQ

-

-

-

701

758

814

870

926

982

533

533

533

533

589

645

533

533

533

533

533

533

533

533

533

533

533

533

07SQ

730

779

827

876

924

972

585

585

585

585

633

682

1021

1069

1166

585

585

585

585

585

585

585

585

585

585

585

585

60 VAV-PRC012-EN

Electrical Data

Table 72. Minimum unit electric heat L/s guidelines (PSC)

Unit kW

11

12

13

14

15

16

6.5

7

7.5

8

9

10

17

18

20

3.5

4

4.5

5

5.5

6

0.5

1

1.5

2

2.5

3

02SQ

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

95

108

121

134

147

160

56

56

56

56

69

82

03SQ

-

-

-

-

-

-

297

-

-

177

189

203

217

243

271

94

109

123

137

149

165

94

94

94

94

94

94

04SQ

297

326

352

382

-

-

177

189

203

217

243

271

-

-

-

149

149

149

149

149

165

149

149

149

149

149

149

L/s

05SQ

297

326

352

382

406

434

177

189

203

217

243

271

459

486

-

165

165

165

165

165

165

165

165

165

165

165

165

Table 73. Minimum unit electric heat Cfm guidelines (ECM)

Unit kW

3.5

4

4.5

5

5.5

6

0.5

1

1.5

2

2.5

3

6.5

7

7.5

8

9

10

03SQ

200

230

260

290

315

350

200

200

200

200

200

200

375

400

430

460

515

575

04SQ

315

315

315

315

315

350

315

315

315

315

315

315

375

400

430

460

515

575

Cfm

05SQ

350

350

350

350

350

350

350

350

350

350

350

350

375

400

430

460

515

575

06SQ

331

358

384

410

437

463

252

252

252

252

278

305

-

-

-

252

252

252

252

252

252

252

252

252

252

252

252

VAV-PRC012-EN

06SQ

560

560

560

560

560

560

560

560

560

560

560

560

560

560

560

560

604

649

07SQ

345

367

390

413

436

459

276

276

276

276

299

322

482

505

550

276

276

276

276

276

276

276

276

276

276

276

276

61

Electrical Data

Table 73. Minimum unit electric heat Cfm guidelines (ECM) (continued)

Cfm

Unit kW

11

12

13

14

15

16

17

18

03SQ

-

-

-

630

-

-

-

-

04SQ

630

690

745

810

-

-

-

-

Table 74. Minimum unit electric heat L/s guidelines (ECM)

Unit kW

11

12

13

14

15

16

17

18

6.5

7

7.5

8

9

10

3.5

4

4.5

5

5.5

6

0.5

1

1.5

2

2.5

3

03SQ

-

-

-

297

-

-

-

-

177

189

203

217

243

271

94

109

123

137

149

165

94

94

94

94

94

94

04SQ

297

326

352

382

-

-

-

-

177

189

203

217

243

271

149

149

149

149

149

165

149

149

149

149

149

149

L/s

05SQ

297

326

352

382

406

434

459

486

177

189

203

217

243

271

165

165

165

165

165

165

165

165

165

165

165

165

05SQ

630

690

745

810

860

920

973

1030

06SQ

327

348

369

390

411

432

-

-

264

264

264

264

285

306

264

264

264

264

264

264

264

264

264

264

264

264

06SQ

693

738

782

826

871

915

-

-

62 VAV-PRC012-EN

Electrical Data

Series Fan-Powered Terminal Units

Table 75. VSEF—electric coil kW guidelines – minimum to maximum (PSC motor units)

Fan

Size Stages 120V 208V

Single-Phase Voltage

240V 277V 347V

02SQ

03SQ

04SQ

05SQ

1

2

1

2

1

2

1

2

0.5-5.0

0.5-5.0

0.5-5.0

0.5-5.0

0.5-4.5

0.5-4.5

0.5-4.5

0.5-4.5

0.5-7.0

0.5-7.0

0.5-9.0

0.5-9.0

0.5-8.0

0.5-8.0

0.5-8.0

0.5-8.0

06SQ

07SQ

1

2

1

2

-

-

-

-

0.5-9.0

0.5-9.0

0.5-8.0

0.5-8.0

(a) 4.5, 5.5, 6.5, 9, 11, 13 kW not available

(b) 12 kW not available

(c) 10, 13 kW not available

(d) 16, 17 kW not available

(e) 18 kW not available

0.5-7.0

0.5-7.0

0.5-10.0

0.5-10.0

0.5-10.0

0.5-10.0

0.5-9.0

0.5-9.0

-

-

-

-

0.5-7.0

1.0-7.0

0.5-12.0

1.0-12.0

0.5-12.0

1.0-12.0

0.5-12.0

1.0-12.0

0.5-12.0

1.0-12.0

0.5-11.0

1.0-11.0

0.5-7.0

1.0-7.0

0.5-14.0

1.0-14.0

0.5-16.0

1.0-16.0

0.5-15.0

1.0-15.0

0.5-15.0

1.0-15.0

0.5-15.0

1.0-15.0

480V

1.0-7.0

1.5-7.0

1.0-13.0

(b)

1.5-13.0

(b)

0.5-18.0

1.0-18.0

0.5-20.0

1.0-20.0

0.5-22.0

1.0-22.0

0.5-20.0

1.0-20.0

208V

0.5-7.0

1.0-7.0

0.5-14.0

1.0-14.0

0.5-15.0

1.0-15.0

0.5-14.0

1.0-14.0

0.5-15.0

1.0-15.0

0.5-14.0

1.0-14.0

Three-Phase Voltage

480V 600V 380V/50Hz

1.0-7.0

3.5-7.0

(a)

1.0-12.0

3.5-12.0

(a)

1.0-18.0

2.5-18.0

1.0-20.0

2.5-20.0

1.0-22.0

2.0-22.0

1.0-24.0

2.0-24.0

1.5-7.0

-

1.5-13.0

-

1.5-18.0

(d)

4.0-15.0

1.5-22.0

4.0-20.0

(e)

1.5-22.0

3.0-22.0

1.5-24.0

3.0-24.0

1.5-7.0

2.5-7.0

1.0-14

(c)

2.5-13

(c)

1.0-18

1.5-18

1.0-22.0

1.5-22.0

1.0-22

1.5-22

-

-

Table 76. VSEF—electric coil kW guidelines – minimum to maximum (ECM units)

Single-Phase Voltage Three-Phase Voltage

Fan

Size Stages

03SQ

04SQ

1

2

1

2

05SQ

06SQ

1

2

1

2

120V 208V

0.5-4.5

0.5-4.5

0.5-4.5

0.5-4.5

0.5-8.0

0.5-8.0

0.5-8.0

0.5-8.0

0.5-4.0

0.5-4.0

0.5-4.0

0.5-4.0

0.5-7.0

0.5-7.0

0.5-7.0

0.5-7.0

240V

0.5-10.0

0.5-10.0

0.5-9.0

0.5-9.0

0.5-8.0

0.5-8.0

0.5-8.0

0.5-8.0

277V

0.5-12.0

1.0-12.0

0.5-12.0

1.0-12.0

0.5-11.0

1.0-11.0

0.5-11.0

1.0-11.0

-

-

-

-

347V

-

-

-

-

480V

1.0-13.0

(a)

1.5-13.0

(a)

0.5-18.0

1.0-18.0

0.5-18.0

1.0-18.0

0.5-22.0

1.0-22.0

208V

0.5-14.0

1.0-14.0

0.5-14.0

1.0-14.0

0.5-12.0

1.0-12.0

0.5-12.0

1.0-12.0

480V

1.0-12.0

3.5-12.0

(b)

1.0-18.0

(c)

2.5-15.0

1.0-22.0

2.5-20.0

1.0-22.0

2.0-22.0

600V

-

-

-

-

-

-

-

-

Notes:

1. Coils available with electric, 24 VAC magnetic or contactors, load carrying P.E. switches, and P.E. switches with magnetic or mercury contactors.

2. Available kW increments are by 0.5 from 0.5 to 8.0 kW, by 1.0 kW from 9.0 to 17.0 kW, and by 2.0 kW from 18.0 to 24.0 kW.

3. Each stage will be equal in kW output.

4. All heaters contain an auto reset thermal cutout and a manual reset cutout.

5. See section

“Formulas,” p. 73

for formulas used to calculate the current amp draw for the heater elements.

6. Recommended coil temperature rise = 20°-30°F (-7° to -1°C). Maximum temperature rise = 55°F (12°C).

7. Heaters should not operate at cfms below the nameplate minimum.

(a) 12 kW not available

(b) 4.5, 5,5, 6.5, 9, 11 kW not available

(c) 16, 17 kW not available

380V/

50Hz

-

-

-

-

-

-

-

-

Table 77. Fan electrical performance (PSC)

Fan Size

02SQ

03SQ

04SQ

05SQ

06SQ

HP

1/8

1/3

1/3

1/2

1/2

115 VAC

1.6

4.3

5.5

6.7

-

Maximum Fan Motor Amperage (FLA)

208 VAC

-

-

-

-

4.6

277 VAC

0.7

1.6

2.0

2.4

3.8

VAV-PRC012-EN 63

Electrical Data

Table 77. Fan electrical performance (PSC)

07SQ 1 6.6

4.7

Notes:

1. Electric Heat Units—Units with fan sizes 02SQ to 05SQ and a primary voltage of 208/60/1, 208/60/3 or 0/60/1 use 115/60/1 VAC fan motors. Fan sizes 06SQ and 07SQ in these same voltages, have 208/60/1 VAC fan motors.

2. Electric Heat Units—Units with primary voltage of 277/60/1, 480/60/1 or 480/60/3 use 277 VAC fan motors.

3. Electric Heat Units—Units with primary voltage of 347/60/1 or 575/60/3 use 347 VAC fan motors.

4. With 380/50/3 and 230/50/1 use 230/50 motors.

Table 78. Fan electrical performance (ECM)

Fan Size

03SQ

04SQ

05SQ

06SQ

HP

1/3

½

1

1

Maximum Fan Motor Amperage (FLA)

120 VAC

4.5

6.5

10.1

9.5

277 VAC

2.4

3.5

5.4

5.1

Notes:

1. Acceptable selections are any point within the shaded area. The ECM will operate on a vertical performance line using the solid state speed controller provided.

2. The ECM motor provides constant volume with changing static pressure conditions. Therefore, the fan curves for the ECM are different compared to fan curves with PSC motors.

3. By using an ECM motor, less fan sizes are used because of the wider turn-down ratios.

Table 79. Minimum unit electric

Unit kW

11

12

13

14

15

16

6.5

7

7.5

8

9

10

17

18

20

22

24

3.5

4

4.5

5

5.5

6

0.5

1

1.5

2

2.5

3

02SQ

-

-

-

-

-

-

372

395

-

-

-

-

-

-

-

-

-

236

259

282

304

327

350

191

191

191

191

191

214

64

03SQ

630

690

745

810

-

-

375

400

430

460

515

575

-

-

-

-

-

260

260

260

290

315

350

260

260

260

260

260

260

Heat Cfm Guidelines (PSC)

04SQ 05SQ

630

690

745

810

860

920

375

400

430

460

515

575

315

315

315

315

315

350

315

315

315

315

315

315

973

1030

-

-

-

630

690

745

810

860

920

400

400

430

460

515

575

400

400

400

400

400

400

400

400

400

400

400

400

973

1030

1150

1260

-

06SQ

713

792

872

951

1031

1110

700

700

700

700

700

700

700

700

700

700

700

700

700

700

700

700

700

700

1190

1269

1428

1587

-

07SQ

850

902

954

1006

1057

1109

850

850

850

850

850

850

850

850

850

850

850

850

850

850

850

850

850

850

1161

1213

1317

1420

1524

VAV-PRC012-EN

Electrical Data

Table 80. Minimum unit electric

Unit kW

11

12

13

14

15

16

6.5

7

7.5

8

9

10

17

18

20

22

24

3.5

4

4.5

5

5.5

6

0.5

1

1.5

2

2.5

3

02SQ

-

-

-

-

-

-

-

-

-

176

186

-

-

-

-

-

-

112

122

133

144

154

165

90

90

90

90

90

101

03SQ

297

326

352

382

-

-

177

189

203

217

243

271

-

-

-

-

-

123

123

123

137

149

165

123

123

123

123

123

123

Heat L/s Guidelines (PSC)

04SQ 05SQ

297

326

352

382

406

434

177

189

203

217

243

271

459

486

-

-

-

149

149

149

149

149

165

149

149

149

149

149

149

297

326

352

382

406

434

189

189

203

217

243

271

459

486

543

595

-

189

189

189

189

189

189

189

189

189

189

189

189

06SQ

336

374

411

449

486

524

330

330

330

330

330

330

562

599

674

749

-

330

330

330

330

330

330

330

330

330

330

330

330

07SQ

401

426

450

475

499

524

401

401

401

401

401

401

548

572

621

670

719

401

401

401

401

401

401

401

401

401

401

401

401

VAV-PRC012-EN 65

Electrical Data

Table 81. Minimum unit electric

Unit kW

11

12

13

14

15

16

17

18

20

22

6.5

7

7.5

8

9

10

3.5

4

4.5

5

5.5

6

0.5

1

1.5

2

2.5

3

03SQ

630

690

745

810

-

-

-

-

-

-

375

400

430

460

515

575

260

260

260

290

315

350

260

260

260

260

260

260

Heat Cfm Guidelines (ECM)

04SQ 05SQ

630

690

745

810

860

920

375

400

430

460

515

575

973

1030

-

-

315

315

315

315

315

350

315

315

315

315

315

315

630

690

745

810

860

920

400

400

430

460

515

575

973

1030

1150

1260

400

400

400

400

400

400

400

400

400

400

400

400

06SQ

1006

1038

1069

1101

1133

1164

943

943

943

943

943

975

1196

1228

1291

1354

943

943

943

943

943

943

943

943

943

943

943

943

66 VAV-PRC012-EN

Table 82. Minimum unit electric

Unit kW

11

12

13

14

15

16

17

18

20

22

6.5

7

7.5

8

9

10

3.5

4

4.5

5

5.5

6

0.5

1

1.5

2

2.5

3

03SQ

297

326

352

382

-

-

-

-

-

-

177

189

203

217

243

271

123

123

123

137

149

165

123

123

123

123

123

123

Heat L/s Guidelines (ECM)

04SQ 05SQ

297

326

352

382

406

434

177

189

203

217

243

271

459

486

-

-

149

149

149

149

149

165

149

149

149

149

149

149

297

326

352

382

406

434

189

189

203

217

243

271

459

486

543

595

189

189

189

189

189

189

189

189

189

189

189

189

Electrical Data

06SQ

475

490

505

520

535

549

445

445

445

445

445

460

564

579

609

639

445

445

445

445

445

445

445

445

445

445

445

445

VAV-PRC012-EN 67

Electrical Data

Low Height Parallel Fan-Powered Terminal Units

Table 83. LPEF—electric coil kW guidelines – minimum to maximum (PSC motor units)

Single-Phase Voltage Three-Phase Voltage

Fan Size Stages

08SQ

09SQ

10SQ

1

2

1

2

1

2

120V

0.5-4.5

0.5-4.5

0.5-4.5

0.5-4.5

0.5-4.0

0.5-4.0

208V

0.5-7.0

0.5-7.0

0.5-8.0

0.5-8.0

0.5-8.0

0.5-8.0

240V

0.5-7.0

0.5-7.0

0.5-10.0

0.5-10.0

0.5-9.0

0.5-9.0

277V

0.5-7.0

1.0-7.0

0.5-12.0

1.0-12.0

0.5-12.0

1.0-12.0

347V

0.5-7.0

1.0-7.0

0.5-14.0

1.0-14.0

0.5-14.0

1.0-14.0

480V

0.5-7.0

1.0-7.0

0.5-14.0

1.0-14.0

0.5-14.0

1.0-14.0

208V

0.5-7.0

1.0-7.0

0.5-14.0

1.0-14.0

1.0-13.0

1.0-13.0

480V

1.0-7.0

2.0-7.0

1.0-14.0

2.0-14.0

1.0-14.0

2.0-14.0

600V

1.5-7.0

3.0-7.0

1.5-14.0

3.0-14.0

1.5-12.0

3.0-12.0

380V/

50Hz

-

-

-

-

-

-

Table 84. LPEF–electric coil kW guidelines – minimum to maximum (ECM units)

Fan Size Stages

08SQ

09SQ

1

2

1

2

120V

0.5-5.0

0.5-5.0

0.5-4.5

0.5-4.5

208V

0.5-7.0

0.5-7.0

0.5-8.0

0.5-8.0

Single-Phase Voltage

240V

0.5-7.0

0.5-7.0

0.5-9.0

0.5-9.0

277V

0.5-7.0

1.0-7.0

0.5-12.0

1.0-12.0

347V

-

-

-

-

480V

0.5-7.0

1.0-7.0

0.5-14.0

1.0-14.0

208V

0.5-7.0

1.0-7.0

0.5-14.0

1.0-14.0

Three-Phase Voltage

480V

1.0-7.0

2.0-7.0

1.0-14.0

2.0-14.0

600V

Notes:

1. Coils available with 24 VAC magnetic or mercury contactors, load carrying P.E. switches, and P.E. switch with magnetic or mercury contractors.

2. Available kW increments are by 0.5 from 0.5 kW to 8.0 kW and by 1.0 kW from 9.0 to 14.0 kW.

3. Each stage will be equal in kW output.

4. All heaters contain an auto thermal cutout and a manual reset cutout.

5. The current amp draw for the heater elements is calculated by the formula below.

-

-

-

-

380V/

50Hz

-

-

-

-

Table 85. Fan electrical performance (PSC)

Fan Size

08SQ

09SQ

10SQ*

HP

1/3

1/3

2 x 1/8

115 VAC

5.5

5.5

9.4

Maximum Fan Motor Amperage (FLA)

277 VAC

2.5

2.5

3.5

347 VAC

Notes:

1. Electric Heat Units - Units with Primary Voltage of 208/60/1, 208/60/3 or 240/60/1 use 115 VAC fan motors.

2. Electric Heat Units - Units with Primary Voltage of 277/60/1, 480/60/1 or 480/60/3 use 277 VAC fan motors.

3. Electric Heat Units - Units with Primary Voltage of 347/60/1 or 575/60/3 use 347 VAC fan motors.

4. Values are for standard, single-speed, permanent split capacitor type motors. Consult factory for non-standard motor performance.

5. Motor amps for 10SQ are total amps for two motors.

1.8

1.8

3.0

Table 86. Fan electrical performance (ECM)

Fan Size

08SQ

09SQ

HP

1/2

1/2

Maximum Fan Motor Amperage (FLA)

115 VAC 277 VAC

2.0

6.7

1.1

3.6

68 VAV-PRC012-EN

Electrical Data

Table 87. Minimum unit electric heat guidelines

Unit kW

6.5

7

7.5

8

9

10

11

12

13

14

3.5

4

4.5

5

5.5

6

0.5

1

1.5

2

2.5

3

08SQ

378

407

-

-

-

-

-

-

-

-

202

232

261

290

319

349

173

173

173

173

173

173

Cfm (PSC

)

09SQ

440

440

468

496

552

608

664

720

776

832

440

440

440

440

440

440

440

440

440

440

440

440

10SQ

720

720

720

720

720

720

720

720

720

-

720

720

720

720

720

720

720

720

720

720

720

720

Unit kW

6.5

7

7.5

8

9

10

11

12

13

14

3.5

4

4.5

5

5.5

6

0.5

1

1.5

2

2.5

3

Table 88. Minimum unit electric heat Cfm guidelines (ECM)

08SQ

Cfm (ECM)

09SQ

409

440

-

-

-

-

-

-

-

-

220

251

283

314

346

377

188

188

188

188

188

188

490

490

514

539

588

637

685

734

783

832

490

490

490

490

490

490

490

490

490

490

490

490

Unit kW

6.5

7

7.5

8

9

10

11

12

13

14

3.5

4

4.5

5

5.5

6

0.5

1

1.5

2

2.5

3

Unit kW

6.5

7

7.5

8

9

10

11

12

13

14

3.5

4

4.5

5

5.5

6

0.5

1

1.5

2

2.5

3

08SQ

178

192

-

-

-

-

-

-

-

-

95

109

123

137

151

164

82

82

82

82

82

82

L/s (PSC

)

09SQ

208

208

221

234

261

287

313

340

366

393

208

208

208

208

208

208

208

208

208

208

208

208

10SQ

340

340

340

340

340

340

340

340

340

-

340

340

340

340

340

340

340

340

340

340

340

340

08SQ

193

208

-

-

-

-

-

-

-

-

104

118

133

148

163

178

89

89

89

89

89

89

L/s (ECM)

09SQ

231

231

243

254

277

300

323

347

370

393

231

231

231

231

231

231

231

231

231

231

231

231

VAV-PRC012-EN 69

Electrical Data

Low Height Series Fan-Powered Terminal Units

Table 89. LSEF-electric coil kW guidelines-minimum to maximum (PSC motor units)

Fan Size Stages

08SQ

1

2

09SQ

10SQ

1

2

1

2

120V 208V

0.5-4.5

0.5-4.5

0.5-6.0

0.5-6.0

0.5-4.5

0.5-4.5

0.5-4.0

0.5-4.0

0.5-8.0

0.5-8.0

0.5-7.5

0.5-7.5

Single-Phase Voltage

240V

-

-

0.5-10.0

0.5-10.0

0.5-8.0

0.5-8.0

277V

0.5-6.0

0.5-6.0

0.5-12.0

1.0-12.0

0.5-11.0

1.0-11.0

347V

0.5-6.0

1.0-6.0

0.5-12.0

1.0-12.0

0.5-15.0

1.0-15.0

480V

0.5-6.0

1.0-6.0

0.5-12.0

1.0-12.0

0.5-18.0

1.0-18.0

Three-Phase Voltage

208V

0.5-6.0

1.0-6.0

0.5-12.0

1.0-12.0

0.5-13.0

1.0-13.0

480V

1.0-6.0

3.0-6.0

1.0-12.0

3.0-12.0

1.0-18.0

2.0-18.0

600V

1.5-6.0

5.0-5.0

1.5-12.0

4.5, 5, 9, 10

1.5-18.0

3.0-18.0

380V/

50Hz

-

-

-

-

-

-

Table 90. LSEF-electric coil kW guidelines-minimum to maximum (ECM units)

Single-Phase Voltage Three-Phase Voltage

Fan Size Stages

08SQ

1

2

09SQ

10SQ

1

2

1

2

120V

0.5-5.0

0.5-5.0

0.5-4.5

0.5-4.5

0.5-4.5

0.5-4.5

208V

0.5-6.0

0.5-6.0

0.5-8.0

0.5-8.0

0.5-8.0

0.5-8.0

240V

0.5-6.0

0.5-6.0

0.5-10.0

0.5-10.0

0.5-9.0

0.5-9.0

277V

0.5-6.0

1.0-6.0

0.5-12.0

1.0-12.0

0.5-12.0

1.0-12.0

347V

-

-

-

-

-

-

480V

0.5-6.0

1.0-6.0

0.5-12.0

1.0-12.0

0.5-18.0

1.0-18.0

208V

0.5-6.0

1.0-6.0

0.5-12.0

1.0-12.0

0.5-14.0

1.0-14.0

480V

1.0-6.0

3.0-6.0

1.0-12.0

3.0-12.0

1.0-18.0

2.0-18.0

Notes:

1. Coils available with 24 VAC magnetic or mercury contactors, load carrying P.E. switches, and P.E. switch with magnetic or mercury contactors.

2. Available kW increments are by 0.5 from 0.5 kW to 8.0 kW and by 1.0 kW from 9.0 to 18.0 kW.

3. Each stage will be equal in kW output.

4. All heaters contain an auto thermal cutout and a manual reset cutout.

5. The current amp draw for the heater elements is calculated by the formula below.

600V

-

-

-

-

-

-

380V/

50Hz

-

-

-

-

-

-

Table 91. Fan electrical performance (PSC)

Fan Size

08SQ

09SQ

10SQ*

HP 115 VAC

1/3 5.5

1/3

2 x 1/3

5.5

11.0

Maximum Fan Motor Amperage (FLA)

277 VAC

2.5

2.5

5.0

347 VAC

1.8

Notes:

1. Electric Heat Units - Units with Primary Voltage of 208/60/1, 208/60/3 or 240/60/1 use 115 VAC fan motors.

2. Electric Heat Units - Units with Primary Voltage of 277/60/1, 480/60/1 or 480/60/3 use 277 VAC fan motors.

3. Electric Heat Units - Units with Primary Voltage of 347/60/1 or 575/60/3 use 347 VAC fan motors.

4. Values are for standard, single-speed, permanent split capacitor type motors. Consult factory for non-standard motor performance.

5. Motor amps for 10SQ are total amps for two motors.

1.8

3.5

Table 92. Fan electrical performance (ECM)

Fan Size

08SQ

09SQ

10SQ

HP 115 VAC

1/2 1.3

1/2

2 x 1/2

Maximum Fan Motor Amperage (FLA)

5.0

7.5

277 VAC

.7

2.7

4.0

70 VAV-PRC012-EN

Table 93. Minimum unit electric heat guidelines

(PSC)

Unit kW

11

12

13

14

15

16

17

18

6.5

7

7.5

8

9

10

3.5

4

4.5

5

5.5

6

0.5

1

1.5

2

2.5

3

08SQ

-

-

-

-

-

-

-

-

-

-

-

-

-

-

276

293

309

325

341

357

228

228

228

228

244

260

Cfm

09SQ

635

687

-

-

-

-

-

-

403

429

455

480

532

584

377

377

377

377

377

377

377

377

377

377

377

377

10SQ

655

708

762

815

869

923

976

1030

440

440

467

494

547

601

440

440

440

440

440

440

440

440

440

440

440

440

Electrical Data

Unit kW

11

12

13

14

15

16

17

18

6.5

7

7.5

8

9

10

3.5

4

4.5

5

5.5

6

0.5

1

1.5

2

2.5

3

08SQ

-

-

-

-

-

-

-

-

-

-

-

-

-

-

130

138

146

153

161

168

108

108

108

108

115

123

10SQ

309

334

360

385

410

435

461

486

208

208

220

233

258

284

208

208

208

208

208

208

208

208

208

208

208

208

L/s

09SQ

300

324

-

-

-

-

-

-

190

202

215

227

251

275

178

178

178

178

178

178

178

178

178

178

178

178

VAV-PRC012-EN 71

Electrical Data

Table 94. Minimum unit electric heat guidelines (ECM)

Unit kW

11

12

13

14

15

16

17

18

6.5

7

7.5

8

9

10

3.5

4

4.5

5

5.5

6

0.5

1

1.5

2

2.5

3

08SQ

-

-

-

-

-

-

-

-

-

-

-

-

-

-

221

253

284

315

346

377

128

128

128

128

159

190

Cfm

09SQ

635

687

-

-

-

-

-

-

403

429

455

480

532

584

377

377

377

377

377

377

377

377

377

377

377

377

10SQ

680

730

779

829

879

929

979

1029

480

480

505

530

580

630

480

480

480

480

480

480

480

480

480

480

480

480

08SQ

-

-

-

-

-

-

-

-

-

-

-

-

-

-

104

119

134

149

163

178

60

60

60

60

75

90

Unit kW

11

12

13

14

15

16

17

18

6.5

7

7.5

8

9

10

3.5

4

4.5

5

5.5

6

0.5

1

1.5

2

2.5

3

L/s

09SQ

300

324

-

-

-

-

-

-

190

202

215

227

251

276

178

178

178

178

178

178

178

178

178

178

178

178

10SQ

321

345

368

391

415

438

462

486

227

227

238

250

274

297

227

227

227

227

227

227

227

227

227

227

227

227

72 VAV-PRC012-EN

Electrical Data

Formulas

Fan-Powered Parallel

Minimum Circuit Ampacity (MCA) Equation

MCA = 1.25 x (

 motor amps + heater amps)

Motor amps is the sum of all motor current draws if more than one is used in the unit.

Maximum Overcurrent Protection (MOP) Equation

MOP = (2.25 x motor1 amps) + motor2 amps + heater amps motor1 amps = current draw of largest motor motor2 amps = sum of current of all other motors used in unit

General Sizing Rules:

• If MOP = 15, then fuse size = 15

• If MOP = 19, then fuse size = 15 with one exception. If heater amps x 1.25 > 15, then fuse size = 20.

• If MOP is equal to or less than MCA, then choose next fuse size greater than MCA.

• Control fusing not applicable.

• Standard Fuse Sizes: 15, 20, 25, 30, 35, 40, 45, 50, and 60.

Example:

A modelVPEF, electric reheat unit size 10-05SQ has 480/3 phase, 12 kW electric reheat with 2 stages and 277-Volt motor.

For MOP of fan-powered unit:

12 kW-480/3 heater:12x1000/480x1.73=14.45 amps

MCA = (2.4 + 14.45) x 1.25 = 21.06, MOP = (2.25 x 2.4) + 14.45 = 19.9.

Since MOP is less than or equal to MCA, then MOP = 25.

For total current draw of unit:

12kW-480/3 heater:12x1000/480x1.73=14.45

Two heat outputs (2 stages) @0.5 amps max each=1.00

Motor amps: 277 V (Fan size 0517) =2.4

Amps Max: 18.35

Useful Formulas: kW

=

ATD

=

|

ATD

= kW

amps

=

PrimaryVoltage 

amps

= kW = 1214 x L/s x ATD

VAV-PRC012-EN 73

Electrical Data

Fan-Powered Series

Minimum Circuit Ampacity (MCA) Equation

• MCA = 1.25 x (Smotor amps + heater amps)

Here motor amps is the sum of all motor current draws if more than one is used in the unit.

Maximum Overcurrent Protection (MOP) Equation

• MOP = (2.25 x motor 1amps) + motor2 amps + heater amps motor1 amps = current draw of largest motor motor2 amps = sum of current draw of all other motors used in units

General Sizing Rules:

• If MOP = 15, then fuse size = 15

• If MOP = 19, then fuse size = 15 with one exception. If heater amps x 1.25 > 15, then fuse size = 20.

• If MOP is less than/equal to MCA, then choose next fuse size greater than MCA.

• Control fusing not applicable.

• Standard Fuse Sizes: 15, 20, 25, 30, 35, 40, 45, 50, and 60.

Example:

A model VSEF, electric reheat unit size 10-0517 has 480/3 phase, 12 kW electric reheat with 2 stages and 277-Volt motor.

For MOP of fan-powered unit:

12 kW - 480/3 heater:12x1000/480x1.73=14.45 amps.

MCA=(2.4 + 14.45) x 1.25 = 21.06, MOP = (2.25 x 2.4) + 14.45 = 19.9.

Since MOP is less than/equal to MCA, then MOP = 25.

For total current draw of unit:

12 kW—480/3 heater:12x1000/480x1.73=14.45

Two heat outputs (2 stages)@0.5 amps max each=1.00

Motor amps: 277 V (Fan size 0517)=2.4

Total amps max: 18.35

Used Formulas:

amps

=

PrimaryVoltage  kW

=

ATD

=

ATD

= kW

amps

= kW=1214 x L/s x ATD

74 VAV-PRC012-EN

Electrical Data

Low Height Parallel Fan-Powered

Minimum Circuit Ampacity (MCA) = (motor amps + heater amps) x 1.25

Maximum Overcurrent Protection (MOP) = (2.25 x motor amps) + heater amps

General Sizing Rules:

• If MOP = 15, then fuse size = 15

• If MOP = 19, then fuse size = 15 with one exception. If heater amps x 1.25 > 15, then fuse size = 20.

• If MOP £ MCA, then choose next fuse size greater than MCA.

• Control fusing not applicable.

• Standard Fuse Sizes: 15, 20, 25, 30, 35, 40, 45, 50, and 60.

Useful Formulas:

kW

=

ATD

=

ATD

= kW

 kW

=

 

amps

=

PrimaryVoltage 

amps

=

Low-Height Series Fan-Powered

Minimum Circuit Ampacity (MCA) = (motor amps + heater amps) x 1.25

Maximum Overcurrent Protection (MOP) = (2.25 x motor amps) + heater amps

General Sizing Rules:

• If MOP = 15, then fuse size = 15

• If MOP = 19, then fuse size = 15 with one exception. If heater amps x 1.25 > 15, then fuse size = 20.

• If MOP is less than/equal to MCA, then choose next fuse size greater than MCA.

• Control fusing not applicable.

• Standard Fuse Sizes: 15, 20, 25, 30, 35, 40, 45, 50, and 60.

Useful Formulas

kW

=

3amps

=

PrimaryVoltage  3

ATD

= kW

=

1amps

=

ATD

= kW

1214 Lls

VAV-PRC012-EN 75