Dimensional Data. Trane Fan-Powered Low-Height Parallel 234 Pages
advertisement
Dimensional Data
Parallel Fan-Powered Terminal Units
PARALLEL COOLING ONLY (VPCF)
FAN
SIZE
02SQ
03SQ
04SQ
05SQ
06SQ
07SQ
INLET SIZE
AVAILABILITY
(NOMINAL Ø")
5", 6", 8", 10"
6", 8", 10", 12"
8", 10", 12", 14"
10", 12", 14"
10", 12", 14", 16"
10", 12", 14", 16"
INLET SIZE
AVAILABILITY
(NOMINAL Ømm)
127 mm, 152 mm, 203 mm, 254 mm
152 mm, 203 mm, 254 mm, 305 mm
203 mm, 254 mm, 305 mm, 356 mm
254 mm, 305 mm, 356 mm
254 mm, 305 mm, 356 mm, 406 mm
254 mm, 305 mm, 356 mm, 406 mm
H
15.50" (394 mm)
17.50" (445 mm)
21.50" (546 mm)
W
40.00" (1016 mm)
L
30.00" (762 mm)
32.50" (826 mm)
40.00" (1016 mm)
DISCHARGE DIMENSIONS
A
19.25" (489 mm)
B
14.00" (356 mm)
16.00" (406 mm)
20.00" (508 mm)
UNIT WT
WT LBS
(kg)
78 (35)
96 (43)
97 (44)
111 (50)
117 (53)
125 (57)
4.
Optional Attenuator
Field Installed
9.
Actuator, Controller and
Fan Controls located in this area
2.
9.
Actuator, Controller and
Fan Controls located in this area
40.00"
(1016 mm)
Airflow
Plenum Inlet
(Valves 5"-14")
(Valve 16")
4.00"
(102 mm)
2.00"
(51 mm)
Flow Ring tubing
20.00"
(508 mm)
Primary
Airflow
Valve 5"
6.50"
(165 mm)
Air
Valve
4.00"
(102 mm)
18.875" Max.
(479 mm)
9.
5.50" Max.
(140 mm)
B
11.30" Max.
(287 mm)
9.
Airflow
Discharge Outlet
A
W back draft damper
Optional Attenuator
Field Installed
L
5.
Panel slides for Motor access
TOP VIEW
5.
20.00"
(508 mm)
DISCHARGE VIEW
30.00"
(762 mm)
H
Fan Size
02SQ
03SQ
04SQ
05SQ
06SQ
07SQ
Filter Size
14" x 20" x 1"
(356 mm x 508 mm x 25 mm)
Attn. Weight
Wt Lbs
(kg)
46 (21)
16" x 20" x 1"
(406 mm x 508 mm x 25 mm)
20" x 20" x 1"
(508 mm x 508 mm x 25 mm)
48 (22)
54 (25)
NOTES:
1. Allow a minimum 6" (152 mm) plenum inlet
clearance for unducted installations.
2. Filter location with optional Attenuator.
3. Attenuator-factory assembled, field installed.
4. See Installation Documents for exact hanger bracket location.
5. For Motor access, remove bottom screw on hanger brackets
to slide panel as shown in drawing.
6. When Attenuator option selected, water coil ships mounted
to attenuator.
7. Air valve centered between top and bottom panel.
8. All high & low voltage controls have same-side NEC
jumpback clearance. (Left-hand shown, right-hand/mirror
image optional.)
9. Maximum dimensions for controls area shown. Configurations
and types of control boxes vary according to control type
selected. See "Enclosure Details" for specific layout.
10. Graphic shown is for left-hand electrical. Right-hand electrical
is a mirror image.
VAV-PRC012-EN 103
Dimensional Data
PARALLEL HOT WATER (VPWF)
FAN
SIZE
INLET SIZE
AVAILABILITY
(NOMINAL Ø")
02SQ
5", 6", 8", 10"
03SQ
04SQ
05SQ
6", 8", 10", 12"
8", 10", 12", 14"
10", 12", 14"
06SQ
07SQ
10", 12", 14", 16"
10", 12", 14", 16"
INLET SIZE
AVAILABILITY
(NOMINAL Ømm)
127 mm, 152 mm, 203 mm, 254 mm
152 mm, 203 mm, 254 mm, 305 mm
203 mm, 254 mm, 305 mm, 356 mm
254 mm, 305 mm, 356 mm
254 mm, 305 mm, 356 mm, 406 mm
254 mm, 305 mm, 356 mm, 406 mm
H
W
15.50" (394 mm)
17.50" (445 mm)
40.00" (1016 mm)
21.50" (546 mm)
L
30.00" (762 mm)
32.50" (826 mm)
40.00" (1016 mm)
DISCHARGE DIMENSIONS
A
19.25" (489 mm)
B
UNIT WT
WT LBS
(kg)
14.00" (356 mm)
78 (35)
16.00" (406 mm)
96 (43)
97 (44)
111 (50)
20.00" (508 mm) 117 (53)
125 (57)
4.
Optional Attenuator
Field Installed
104
9.
Actuator, Controller and
Fan Controls located in this area
(Valves 6"-14")
(Valve 16")
4.00"
(102 mm)
2.00"
(51 mm)
Flow Ring tubing
18.875" Max.
(479 mm)
9.
5.50" Max.
(140 mm)
B
11.30" Max.
(287 mm)
2.
40.00"
(1016 mm)
20.00"
(508 mm)
Water
Coil
Airflow
Plenum Inlet
Coil
Connection
6.30"
(160 mm)
9.
Actuator, Controller and
Fan Controls located in this area
20.00"
(508 mm)
Primary
Airflow
Valve 5"
6.50"
(165 mm)
Air
Valve
4.00"
(102 mm)
Airflow
Discharge Outlet
W back draft damper
Optional Attenuator
Field Installed
L
5.
Panel slides for Motor access
TOP VIEW
5.
20.00"
(508 mm)
30.00"
(762 mm)
H
Fan Size
02SQ
03SQ
04SQ
05SQ
06SQ
07SQ
Filter Size
14" x 20" x 1"
(356 mm x 508 mm x 25 mm)
16" x 20" x 1"
(406 mm x 508 mm x 25 mm)
20" x 20" x 1"
(508 mm x 508 mm x 25 mm)
Attn. Weight
Wt Lbs
(kg)
46 (21)
48 (22)
54 (25)
NOTES:
1. Allow a minimum 6" (152 mm) plenum inlet clearance
for unducted installations.
2. Filter location with optional Attenuator.
3. Attenuator-factory assembled, field installed.
4. See Installation Documents for exact hanger bracket location.
5. For Motor access, remove bottom screw on hanger
brackets to slide panel as shown in drawing.
6. When Attenuator option selected, water coil ships
mounted to attenuator.
7. Air valve centered between top and bottom panel.
8. All high & low voltage controls have same-side NEC
jumpback clearance. (Left-hand shown, right-hand/mirror
image optional.)
9. Maximum dimensions for controls area shown.
9.
A
DISCHARGE VIEW
VAV-PRC012-EN
Dimensional Data
PARALLEL WITH HOT WATER ON DISCHARGE (VPWF)
FAN
SIZE
02SQ
03SQ
04SQ
05SQ
06SQ
07SQ
INLET SIZE
AVAILABILITY
(NOMINAL Ø")
5", 6", 8", 10"
6", 8", 10", 12"
8", 10", 12", 14"
10", 12", 14"
10", 12", 14", 16"
10", 12", 14", 16"
INLET SIZE
AVAILABILITY
(NOMINAL Ømm)
127 mm, 152 mm, 203 mm, 254 mm
152 mm, 203 mm, 254 mm, 305 mm
203 mm, 254 mm, 305 mm, 356 mm
254 mm, 305 mm, 356 mm
254 mm, 305 mm, 356 mm, 406 mm
254 mm, 305 mm, 356 mm, 406 mm
H
15.50" (394 mm)
17.50" (445 mm)
21.50" (546 mm)
W
40.00" (1016 mm)
L
30.00" (762 mm)
32.50" (826 mm)
40.00" (1016 mm)
DISCHARGE DIMENSIONS
A
20.00" (508 mm)
B
14.00" (356 mm)
16.00" (406 mm)
20.00" (508 mm)
UNIT WT
(kg)
78 (35)
96 (43)
97 (44)
111 (50)
117 (53)
125 (57)
4.
Optional Attenuator
Field Installed
8.
Actuator, Controller and
Fan Controls located in this area
2.
40.00"
(1016 mm)
Airflow
Plenum Inlet
8.
Actuator, Controller and
Fan Controls located in this area
(Valves 5"-14")
(Valve 16")
4.00"
(102 mm)
2.00"
(51 mm)
Flow Ring tubing
20.00"
(508 mm)
Primary
Airflow
Valve 5"
6.50"
(165 mm)
Air
Valve
4.00"
(102 mm)
18.875" Max.
(479 mm)
8.
5.50" Max.
(140 mm)
6.30"
(160 mm)
Airflow
Discharge Outlet
Water
Coil
20.00"
(508 mm)
W
B
11.30" Max.
(287 mm)
8.
A
VAV-PRC012-EN
30.00"
(762 mm)
Optional Attenuator
Field Installed
L
5.
Fan Size
02SQ
03SQ
04SQ
05SQ
06SQ
07SQ
Filter Size
14" x 20" x 1"
(356 mm x 508 mm x 25 mm)
16" x 20" x 1"
(406 mm x 508 mm x 25 mm)
20" x 20" x 1"
(508 mm x 508 mm x 25 mm)
Attn. Weight
Wt. Lbs.
(kg)
46 (21)
48 (22)
54 (25)
Panel slides for Motor access
TOP VIEW
5.
20.00"
(508 mm)
H
NOTES:
1. Allow a minimum 6" (152 mm) plenum inlet
clearance for unducted installations.
2. Filter location with optional Attenuator.
3. Attenuator-factory assembled, field installed.
4. See Installation Documents for exact hanger bracket location.
5. For Motor access, remove bottom screw on hanger brackets
to slide panel as shown in drawing.
6. Air valve centered between top and bottom panel.
7. All high & low voltage controls have same-side NEC
jumpback clearance. (Left-hand shown, right-hand/mirror
image optional.)
8. Maximum dimensions for controls area shown.
DISCHARGE VIEW
105
Dimensional Data
106 VAV-PRC012-EN
Dimensional Data
VAV-PRC012-EN 107
Dimensional Data
PARALLEL ELECTRIC HEAT (VPEF)
FAN
SIZE
02SQ
03SQ
04SQ
05SQ
06SQ
07SQ
INLET SIZE
AVAILABILITY
(NOMINAL Ø")
5", 6", 8", 10"
6", 8", 10", 12"
8", 10", 12", 14"
10", 12", 14"
10", 12", 14", 16"
10", 12", 14", 16"
INLET SIZE
AVAILABILITY
(NOMINAL Ømm)
127 mm, 152 mm, 203 mm, 254 mm
152 mm, 203 mm, 254 mm, 305 mm
203 mm, 254 mm, 305 mm, 356 mm
254 mm, 305 mm, 356 mm
254 mm, 305 mm, 356 mm, 406 mm
254 mm, 305 mm, 356 mm, 406 mm
H
15.50" (394 mm)
17.50" (445 mm)
21.50" (546 mm)
W
40.00" (1016 mm)
L
30.00" (762 mm)
32.50" (826 mm)
40.00" (1016 mm)
DISCHARGE DIMENSIONS
A
20.00" (508 mm)
B
14.00" (356 mm)
16.00" (406 mm)
20.00" (508 mm)
UNIT WT
WT LBS
(kg)
120 (54)
96 (43)
138 (63)
141 (64)
178 (80)
186 (84)
5.
Optional Attenuator
Field Installed
108
9.
Actuator, Controller and
Fan Controls located in this area
18.875" Max.
(479 mm)
9.
4.00"
(102 mm)
Flow Ring tubing
20.00"
(508 mm)
Primary
Airflow
Valve 5"
6.50"
(165 mm)
Air
Valve
4.00"
(102 mm)
22.00"
(559 mm)
5.50" Max.
(140 mm)
B
11.30" Max.
(287 mm)
9.
2.
9.
Actuator, Controller and
Fan Controls located in this area
40.00"
(1016 mm)
Optional Attenuator
Field Installed
Airflow
Plenum Inlet
30.00"
(762 mm)
L
4.
Fan Size
02SQ
03SQ
04SQ
05SQ
06SQ
07SQ
Filter Size
14" x 20" x 1"
(356 mm x 508 mm x 25 mm)
16" x 20" x 1"
(406 mm x 508 mm x 25 mm)
20" x 20" x 1"
(508 mm x 508 mm x 25 mm)
Attn. Weight
Wt. Lbs.
(kg)
46 (21)
48 (22)
54 (25)
Heater
Airflow
Discharge Outlet
W
6.00"
(152 mm)
4.
Panel slides for Motor access
TOP VIEW
20.00"
(508 mm)
H
NOTES:
1. Allow a minimum 6" (152 mm) plenum inlet clearance for
unducted installations.
2. Filter location with optional Attenuator.
3. Attenuatory factory assembled, field installed.
4. For motor access, remove bottom screws on hanger brackets
to slide panel as shown in drawing.
5. See Installation Documents for exact hanger bracket location.
6. Air valve centered between top and bottom panel.
7. Heating coil uninsulated. External insulation may be field
supplied and installed as required.
8. All high & low voltage controls have same side NEC jumpback
clearance. (Left-hand shown, right-hand/mirror image optional.)
Maximum dimensions for controls area shown.
and types of control boxes vary according to control type
selected. See "Enclosure Details" for specific layout.
A
DISCHARGE VIEW
VAV-PRC012-EN
Dimensional Data
Series Fan-Powered Terminal Units
SERIES COOLING ONLY (VSCF) WITHOUT ATTENUATOR
FAN
SIZE
02SQ
03SQ
04SQ
05SQ
06SQ
07SQ
INLET SIZE
AVAILABILITY
NOMINAL Ø
INCHES
4, 5, 6, 8, 10
6, 8, 10, 12
6, 8, 10, 12, 14
10, 12, 14
10, 12, 14, 16
10, 12, 14, 16
INLET SIZE
AVAILABILITY
NOMINAL Ø
(mm)
104, 127, 152, 203, 254
152, 203, 254, 305
152, 203, 254, 305, 356
254, 305, 356
254, 305, 356, 406
254, 305, 356, 406
H
15.50" (394 mm)
17.50" (445 mm)
21.50" (546 mm)
W L
DISCHARGE DIMENSIONS
A B
C D
Unit Wt
Lbs
(kg)
22.00" (559 mm)
24.00" (610 mm)
30.00" (762 mm)
34.00" (864 mm)
40.00" (1016 mm)
12.00" (305 mm)
19.00" (483 mm)
14.00" (356 mm)
16.00" (406 mm)
24.00" (610 mm)
18.00" (457 mm)
5.00" (127 mm)
2.50" (64 mm)
3.00" (76 mm)
.65" (17 mm)
.75" (19 mm)
78 (35)
85 (39)
86 (39)
1.66" (42 mm)
100 (45)
117 (53)
125 (57)
2.
7.
Airflow
Plenum Inlet
TOP VIEW
Filter
5.50" Max.
(140 mm)
11.30" Max.
(287 mm)
7.
(Valves 4"-14")
4.00"
(102 mm)
Flow Ring
Tubing
W
Primary
Airflow
Air
Valve
Valves 4" & 5"
6.50"
(165 mm)
4.00"
(102 mm)
18.875" Max.
(479 mm)
7.
Actuator, Controller and
Fan Controls located in this area
L
Airflow
Discharge Outlet
Panel slides for Motor access
B
H
D
4.
Fan Size
02SQ
03SQ
04SQ
05SQ
06SQ
07SQ
Filter Size
14" x 14" x 1"
(356 mm x 356 mm x 25 mm)
16" x 20" x 1"
(406 mm x 508 mm x 25 mm)
20" x 20" x 1"
(508 mm x 508 mm x 25 mm)
NOTES:
1. Allow a minimum 6" (152 mm) plenum inlet clearance for
unducted installations.
2. See Installation Documents for exact hanger bracket location.
3. Air valve centered between top and bottom panel.
4. For motor access, remove bottom screw on hanger brackets
to slide panel as shown in drawing.
5. Attenuator option not available with this unit layout.
6. All high & low voltage controls have same-side NEC jumpback
clearance. (Left-hand shown, right-hand/mirror image optional.)
types of control boxes vary according to control types selected.
A C
DISCHARGE VIEW
VAV-PRC012-EN 109
Dimensional Data
110 VAV-PRC012-EN
Dimensional Data
NARROW CORRIDOR DESIGN SERIES COOLING (VSCF) WITHOUT ATTENUATOR
VAV-PRC012-EN
NOTES:
1. Allow a minimum 6" (152 mm) plenum inlet
clearance for unducted installations.
2. See installation Documents for exact hanger bracket location.
3. Air valve centered between top and bottom panel.
4. For Motor access, remove bottom screw on hanger
brackets to slide panel as shown in drawing.
5. Attenuator option not available with this unit layout.
6. All high & low voltage controls have same-side NEC
jumpback clearance. (unit shown w/left hand high &
low voltage box connections [high voltage inlet facing].
Right hand connections available.)
7. Maximum dimensions for controls are shown.
111
Dimensional Data
112 VAV-PRC012-EN
Dimensional Data
SERIES HOT WATER (VSWF) WITHOUT ATTENUATOR
FAN
SIZE
02SQ
03SQ
04SQ
05SQ
06SQ
07SQ
INLET SIZE
AVAILABILITY
NOMINAL Ø
INCHES
4, 5, 6, 8, 10
6, 8, 10, 12
6, 8, 10, 12, 14
10, 12, 14
10, 12, 14, 16
10, 12, 14, 16
INLET SIZE
AVAILABILITY
NOMINAL Ø
(mm)
104, 127, 152, 203, 254
152, 203, 254, 305
152, 203, 254, 305, 356
254, 305, 356
254, 305, 356, 406
254, 305, 356, 406
H W L
DISCHARGE DIMENSIONS
A
B
C D E
Unit Wt
Lbs
(kg)
15.50" (394 mm)
17.50" (445 mm)
22.00" (559 mm)
24.00" (610 mm)
21.50" (546 mm)
30.00" (762 mm)
34.00" (864 mm)
40.00" (1016 mm)
12.00" (305 mm)
19.00" (483 mm)
24.00" (610 mm)
14.00" (356 mm)
16.00" (406 mm)
5.00" (127 mm)
2.50" (64 mm)
18.00" (457 mm)
3.00" (76 mm)
.65" (17 mm)
.75" (19 mm)
1.66" (42 mm)
6.75" (171 mm)
10.75" (273 mm)
6.75" (171 mm)
78 (35)
85 (39)
86 (39)
100 (45)
117 (53)
125 (57)
2.
W
(Valves 4"-14")
4.00"
(102 mm)
2.00"
(Valve 16") (51 mm)
Flow Ring
Tubing
Primary
Airflow
Air
Valve
Valves 4" & 5"
6.50"
(165 mm)
4.00"
(102 mm)
18.875" Max.
(479 mm)
9.
Actuator, Controller and
Fan Controls located in this area
L
9.
Airflow
Plenum Inlet
4.
Filter
3.00" x 7.00"
(76 mm x 178 mm)
Coil Access
Coil Connection
TOP VIEW
5.50" Max.
(140 mm)
11.30" Max.
(287 mm)
9.
Water Coil
Airflow
Discharge Outlet
Panel slides for Motor access
E
B
H
D
Fan Size
02SQ
03SQ
04SQ
05SQ
06SQ
07SQ
Filter Size
14" x 14" x 1"
(356 mm x 356 mm x 25 mm)
16" x 20" x 1"
(406 mm x 508 mm x 25 mm)
20" x 20" x 1"
(508 mm x 508 mm x 25 mm)
NOTES:
1. Allow a minimum 6" (152 mm) plenum inlet clearance for
unducted installations.
2. See Installation Documents for exact hanger bracket location.
3. Air valve centered between top and bottom panel.
4. For motor access, remove bottom screw on hanger brackets
to slide panel as shown in drawing.
5. Attenuator option not available with this unit layout.
6. Heating coil uninsulated. External insulation may be field-
supplied and installed as required.
7. Rotate coil 180 for right-hand coil connection.
8. All high & low voltage controls have same-side NEC jumpback
clearance. (Left-hand shown, right-hand/mirror image optional.)
Maximum dimensions for controls area shown.
types of control boxes vary according to control types selected. See
"Enclosure Details" for specific layout.
A
C
DISCHARGE VIEW
VAV-PRC012-EN 113
Dimensional Data
114 VAV-PRC012-EN
Dimensional Data
NARROW CORRIDOR DESIGN SERIES HOT WATER (VSWF) WITHOUT ATTENUATOR
VAV-PRC012-EN
NOTES:
1. Allow a minimum 6" (152 mm) plenum inlet
clearance for unducted installations.
2. See Installation Documents for exact hanger
bracket location.
3. Air valve centered between top and bottom panel.
4. For motor access, remove bottom screw on
hanger brackets to slide panel as shown in drawing.
5. Attenuator option not available with this unit layout.
6. Heating coil un-insulated. External insulation may be
field supplied and installed as required.
7. Rotate coil 180° for right hand coil connection.
8. All high & low voltage controls have same-side NEC
jumpback clearance. (unit shown w/left hand high &
low voltage box connections [high voltage inlet facing].
Right hand connections available.)
9. Maximum dimensions for controls area shown.
115
Dimensional Data
116 VAV-PRC012-EN
COIL INFORMATION FOR SERIES 1-ROW COIL
Dimensional Data
VAV-PRC012-EN 117
Dimensional Data
COIL INFORMATION FOR SERIES 2-ROW COILS
118 VAV-PRC012-EN
Dimensional Data
SERIES ELECTRIC (VSEF) WITHOUT ATTENUATOR
FAN
SIZE
INLET SIZE
AVAILABILITY
NOMINAL Ø
INCHES
4, 5, 6, 8, 10 02SQ
03SQ
04SQ
05SQ
6, 8, 10, 12
6, 8, 10, 12, 14
10, 12, 14
06SQ 10, 12, 14, 16
07SQ
10, 12, 14, 16
INLET SIZE
AVAILABILITY
NOMINAL Ø
(mm)
104, 127, 152, 203, 254
152, 203, 254, 305
152, 203, 254, 305, 356
254, 305, 356
254, 305, 356, 406
254, 305, 356, 406
H
15.50" (394 mm)
17.50" (445 mm)
21.50" (546 mm)
W
30.00" (762 mm)
L
22.00" (559 mm)
24.00" (610 mm)
34.00" (864 mm)
40.00" (1016 mm)
DISCHARGE DIMENSIONS
A
B
C
D
12.00" (305 mm) 10.00" (254 mm)
12.00" (305 mm)
16.00" (406 mm)
19.00" (483 mm)
14.00" (356 mm)
5.00" (127 mm)
4.00" (102 mm)
18.00" (457 mm)
4.00" (102 mm) 22.00" (559 mm)
10.00" (254 mm)
5.50" (140 mm)
25.00" (635 mm)
E
18.50" (470 mm)
17.00" (432 mm)
Unit Wt
Lbs
(kg)
78 (35)
85 (39)
86 (39)
100 (45)
117 (53)
125 (57)
2.
W
(Valves 4"-14")
(Valve 16")
4.00"
(102 mm)
2.00"
(51 mm)
Flow Ring
Tubing
Primary
Airflow
Air
Valve
Valves 4" & 5"
6.50"
(165 mm)
4.00"
(102 mm)
18.875" Max.
(479 mm)
8.
Airflow
Plenum Inlet
Fans
02SQ
Fans
03SQ–05SQ
Fans
06SQ–07SQ
Filter
1.00"
(25 mm)
2.00"
(51 mm)
0.60"
(15 mm)
TOP VIEW
E
6.20"
(157 mm)
5.50" Max.
(140 mm)
11.30" Max.
(287 mm)
8.
DISCHARGE VIEW
Electric
Heater
Airflow
Discharge Outlet
D
A
Panel slides for Motor access
L
8.
Actuator, Controller and
Fan Controls located in this area
4.
Fan Size
02SQ
03SQ
04SQ
05SQ
06SQ
07SQ
Filter Size
14" x 14" x 1"
(356 mm x 356 mm x 25 mm)
16" x 20" x 1"
(406 mm x 508 mm x 25 mm)
20" x 20" x 1"
(508 mm x 508 mm x 25 mm)
C
B
Fans
02SQ
Fans
03SQ–05SQ
Fans
06SQ–07SQ
1.50"
(38 mm)
1.50"
(38 mm)
3.00"
(76 mm)
H
NOTES:
1. Allow a minimum 6" (152 mm) plenum inlet clearance for
unducted installations.
2. See Installation Documents for exact hanger bracket location.
3. Air valve centered between top and bottom panel.
4. For motor access, remove bottom screw on hanger brackets
to slide panel as shown in drawing.
5. Attenuator option not available with this unit layout.
6. Heating coil uninsulated. External insulation may be field-
supplied and installed as required.
7. All high & low voltage controls have same-side NEC jumpback
clearance. (Left-hand shown, right-hand/mirror image optional.)
Maximum dimensions for controls area shown.
types of control boxes vary according to control types selected. See
"Enclosure Details" for specific layout.
VAV-PRC012-EN 119
Dimensional Data
120 VAV-PRC012-EN
Dimensional Data
VAV-PRC012-EN 121
Dimensional Data
122 VAV-PRC012-EN
Dimensional Data
Low Height Parallel Fan-Powered Terminal Units
LOW-HEIGHT PARALLEL COOLING (LPCF) FAN SIZES 08SQ & 09SQ
FAN
INLET SIZE
AVAILABILITY
SIZE NOMINAL Ø (INCHES)
INLET SIZE
AVAILABILITY
NOMINAL Ø (mm)
08SQ
09SQ
5, 6, 8
6, 8
127, 152, 203
152, 203
DISCHARGE DIMENSIONS
H W L
A
11.00" (279 mm) 40.00" (1016 mm) 30.00" (762 mm) 19.25" (489 mm)
B
9.5" (241 mm)
09SQ
8 x 14 203 x 356
D
4.00" (102 mm)
3.25" (83 mm)
UNIT WT
WT LBS
(kg)
69 (31.3)
74 (33.6)
83 (37.7)
Optional Attenuator
Field Installed
17.50"
(445 mm)
5.00"
(127 mm)
H
10.50"
(267 mm)
5.
Actuator, Controller and
Fan Controls located in this area
5.
Actuator, Controller and
Fan Controls located in this area
D
Primary
Airflow
Valve 5"
6.50"
(165 mm)
4.00
(102 mm)
Airflow
Discharge Outlet
A
W
32.00"
(813 mm)
Optional Attenuator
Field Installed
Airflow
Plenum Inlet
18.00"
(457 mm)
Rectangular Damper
8" x 14"
(203 mm X 356 mm)
Rectangular Damper Detail
5.
Actuator, Controller and
Fan Controls located in Enclosure
7.
L
Fan Size
08SQ
09SQ
Filter Size
10" x 20" x 1"
(254 mm x 508 mm x 25 mm)
Attn Wt
Wt. Lbs.
(kg)
10 (4.5)
TOP VIEW
B
NOTES:
1. Allow a minimum 6" (152 mm) plenum inlet clearance for unducted
installations.
2. Flanged discharge outlet accepts up to 1" (25 mm) duct flange.
3. Bottom Access panel standard.
4. Air valve centered between top and bottom panel.
5. Control box enclosure provided with all control types.
6. All high & low voltage controls have same-side NEC jumpback
clearance. (Left-hand shown, right-hand/mirror image optional.)
7. Flange adds 2" to width and length of unit.
DISCHARGE VIEW
VAV-PRC012-EN 123
Dimensional Data
LOW-HEIGHT PARALLEL COOLING (LPCF) FAN SIZE 10SQ
FAN
SIZE
10SQ
10SQ
INLET SIZE
AVAILABILITY
NOMINAL Ø (INCHES)
8
8 x 14
INLET SIZE
AVAILABILITY
NOMINAL Ø (mm)
203
203 x 356
H W
11.50" (292 mm)
40.00" (1016 mm)
DISCHARGE DIMENSIONS
L
A
B
50.00" (1270 mm) 19.25" (489 mm)
10.00" (254 mm)
D
4.00" (102 mm)
3.25" (83 mm)
UNIT WT
WT LBS
(kg)
90 (41)
92 (42)
4.
124
Flow Ring tubing
20.00"
(508 mm)
D
Primary
Airflow
Air
Valve
4.00
(102 mm)
18.875" Max.
(479 mm)
20.00"
(508 mm)
L
6.
Actuator, Controller and
Fan Controls located in this area
4.
Rectangular Damper
8" x 14"
(203 mm X 356 mm)
Rectangular Damper Detail
6.
Actuator, Controller and
Fan Controls located in this area
6.
5.50" Max.
(140 mm)
B
11.30" Max.
(287 mm)
6.
Airflow
Discharge Outlet
W
TOP VIEW
Fan Size
10SQ
Filter Size
10" x 20" x 1"
(254 mm x 508 mm x 25 mm)
NOTES:
1. Allow a minimum 6" (152 mm) plenum inlet clearance for unducted installations.
2. Flanged discharge outlet accepts up to a 1" (25 mm) duct flange.
3. Bottom Access panel standard.
4. See Installation Documents for exact hanger bracket location.
5. Air valve centered between top and bottom panel.
6. Maximum dimensions for controls area shown.
H
A
DISCHARGE VIEW
VAV-PRC012-EN
Dimensional Data
LOW-HEIGHT PARALLEL HOT WATER (LPWF) FAN SIZES 08SQ & 09SQ
FAN
SIZE
INLET SIZE
AVAILABILITY
INLET SIZE
AVAILABILITY
NOMINAL Ø (INCHES) NOMINAL Ø (mm)
08SQ
09SQ
09SQ
5, 6, 8
6, 8
8 x 14
127, 152, 203
152, 203
203 x 356
H W
11.00" (279 mm) 40.00" (1016 mm)
DISCHARGE DIMENSIONS
L
30.00" (762 mm)
A
B
19.25" (483 mm) 9.50" (241 mm)
D
UNIT WT
WT LBS
(kg)
4.00" (102 mm) 98 (44.5)
103 (46.7)
3.25" (83 mm) 112 (50.8)
Optional Attenuator
Field Installed
17.50"
(445 mm)
5.00"
(127 mm)
5.
Actuator, Controller and
Fan Controls located in this area
5.
Actuator, Controller and
Fan Controls located in this area
32.00"
(813 mm)
20.00"
(508 mm)
6.80"
(173 mm)
D
Primary
Airflow
Valve 5"
6.50"
(165 mm)
4.00
(102 mm)
Optional Attenuator
Field Installed
Airflow
Plenum Inlet
18.00"
(457 mm)
7.
L
Rectangular Damper
8" x 14"
(203 mm x 356 mm)
Rectangular Damper Detail
5.
Actuator, Controller and
Fan Controls located in Enclosure
Fan Size
08SQ
09SQ
Filter Size
10" x 20" x 1"
(254 mm x 508 mm x 25 mm)
Attn Wt
Wt Lbs
(kg)
10 (4.5)
H
10.50"
(267 mm)
Airflow
Discharge Outlet
W
B
TOP VIEW
NOTES:
1. Allow a minimum 6" (152 mm) plenum inlet clearance for
unducted installations.
2. Flanged discharge outlet accepts up to a 1" (25 mm) duct flange.
3. Bottom Access panel standard.
4. Air valve centered between top and bottom panel.
5. Control box enclosure provided with all control types.
6. All high & low voltage controls have same-side NEC jumpback
clearance. (Left-hand shown, right-hand/mirror image optional.)
7. Flange adds 2" to width and length of unit.
A
DISCHARGE VIEW
VAV-PRC012-EN 125
Dimensional Data
126 VAV-PRC012-EN
Dimensional Data
PARALLEL LOW-HEIGHT HOT WATER (LPWF) COIL ON DISCHARGE
FAN SIZES 08SQ & 09SQ
FAN
SIZE
INLET SIZE
AVAILABILITY
NOMINAL Ø (INCHES)
INLET SIZE
AVAILABILITY
NOMINAL Ø (mm)
H W L
DISCHARGE DIMENSIONS
08SQ
09SQ
09SQ
5, 6, 8
6, 8
8 X 14
127, 152, 203
152, 203
203 X 356
11.00" (279 mm) 40.00" (1016 mm) 30.00" (762 mm)
A
20.00" (508 mm)
B
10.00" (254 mm)
D
UNIT WT
WT LBS
(kg)
4.00" (102 mm) 98 (44.5)
103 (46.7)
3.25" (83 mm) 112 (50.8)
Optional Attenuator
Field Installed
5.
Actuator, Controller and
Fan Controls located in this area 5.
Actuator, Controller and
Fan Controls located in this area
17.50"
(445 mm)
5.00"
(127 mm)
32.00"
(813 mm)
D
Primary
Airflow
Valve 5"
6.50"
(165 mm)
4.00
(102 mm)
Optional Attenuator
Field Installed
Airflow
Plenum Inlet
18.00"
(457 mm)
7.
L
Rectangular Damper
8" x 14"
(203 mm X 356 mm)
Rectangular Damper Detail
5.
Actuator, Controller and
Fan Controls located in Enclosure
Fan Size
08SQ
09SQ
Filter Size
10" x 20" x 1"
(254 mm x 508 mm x 25 mm)
Attn Wt
Wt Lbs
(kg)
10 (4.5)
H
10.50"
(267 mm)
6.80"
(173 mm)
20.00"
(508 mm)
Airflow
Discharge Outlet
W
A
B
TOP VIEW
NOTES:
1. Allow a minimum 6" (152 mm) plenum inlet clearance for
unducted installations.
2. Flanged discharge outlet accepts up to a 1" (25 mm) duct flange.
3. Bottom Access panel standard.
4. Air valve centered between top and bottom panel.
5. Control box enclosure provided with all control types.
6. All high & low voltage controls have same-side NEC jumpback clearance.
(Left-hand shown, right-hand/mirror image optional.)
7. Flange adds 2" to width and length of unit.
DISCHARGE VIEW
VAV-PRC012-EN 127
Dimensional Data
Coil Information For Low Height Parallel Inlet-1 Row
Size Inlet/Fan
08SQ
09SQ
10SQ
Coil Connection 1-Row
3/8" (10 mm) O.D.
3/8" (10 mm) O.D.
.375" (10 mm) O.D.
A
9" (229 mm)
9" (229 mm)
9.00" (229 mm)
B
2 7/8" (71 mm)
2 7/8" (71 mm)
2.80" (71 mm)
L
20" (508 mm)
20" (508 mm)
20.00" (508 mm)
H
10" (254 mm)
10" (254 mm)
10.00" (254 mm)
L
OUTLET
A
AIR FLOW
H
INLET
AIR FLOW
B
7/8"
[22mm]
Fan Size
08SQ
09SQ
10SQ
Internal Volume Gal (L)
0.07 (16.7)
0.07 (16.7)
0.07 (.27)
Operating Weight Lbs (Kg)
9.7 (4.4)
9.7 (4.4)
9.7 (4.4)
Notes:
1. Location of coil connections is determined by facing air steam. R.H. Coil connections shown, L.H. not available.
2. Coil furnished with stub sweet connections.
128 VAV-PRC012-EN
Dimensional Data
Coil Information For Low Height Parallel Plenum Inlet 2-Row Coil
Fan Size
08SQ
09SQ
10SQ
Coil Connection 2 Row
7/8" (22 mm) O.D.
7/8" (22 mm) O.D.
.875" (22 mm) O.D.
A
6 1/4" (157 mm)
6 1/4" (157 mm)
6.20" (157 mm)
B
2 1/8" (55 mm)
2 1/8" (55 mm)
2.18" (55 mm)
L
20" (508 mm)
20" (508 mm)
20.00" (508 mm)
H
10" (254 mm)
10" (254 mm)
10.00" (254 mm)
VAV-PRC012-EN
Fan Size
08SQ
09SQ
10SQ
Internal Volume Gal (L)
0.16 (39.0)
0.16 (39.0)
0.16 (.61)
Operating Weight Lbs (Kg)
13.7 (6.2)
13.7 (6.2)
13.7 (6.2)
Notes:
1. Location of coil connections is determined by facing air steam. R.H. Coil connections shown, L.H. not available.
2. Coil furnished with female sweat connections.
3.
0.85" lip NOT on 08SQ or 09SQ units.
129
Dimensional Data
Coil Information For Low Height Parallel Discharge 1-Row Coil
Fan Size
08SQ
09SQ
Coil Connection
3/8" (10 mm) O.D.
3/8" (10 mm) O.D.
A B L H W
9.00" (229 mm) 1.65" (42 mm) 20.00" (508 mm) 10.00" (254 mm) 6.75" (171 mm)
9.00" (229 mm) 1.65" (42 mm) 20.00" (508 mm) 10.00" (254 mm) 6.75" (171 mm)
130
Fan Size
08SQ
09SQ
Internal Volume Gal (L)
0.07 (.28)
0.07 (.28)
Operating Weight Lbs (Kg)
9.7 (4.4)
9.7 (4.4)
Notes:
1. Location of coil connections is determined by facing air stream. L.H. Coil connections shown, R.H. opposit.
2. Coil furnished with stub sweat connections.
3. Coil is rotated to achieve opposite hand connection. Note: Water inlet is always on the bottom and outlet on the top.
4. Access Panel is standard.
VAV-PRC012-EN
Dimensional Data
Coil Information For Low Height Parallel Discharge 2 Row Coil
Fan Size
08SQ
09SQ
Coil Connection
7/8" (22 mm) O.D.
7/8" (22 mm) O.D.
A
6.25" (159 mm)
6.25" (159 mm)
B
2.00 (51 mm)
2.00 (51 mm)
L H
20.00" (508 mm) 10.00" (254 mm)
20.00" (508 mm) 10.00" (254 mm)
W
6.75" (171 mm)
6.75" (171 mm)
VAV-PRC012-EN
Fan Size
08SQ
09SQ
Internal Volume Gal (L)
0.17 (.64)
0.17 (.64)
Operating Weight Lbs (Kg)
13.7 (6.2)
13.7 (6.2)
Notes:
1. Location of coil connections is determined by facing air stream. L.H. Coil connections shown, R.H. opposite.
2. Coil furnished with stub sweat connections.
3. Use port at bottom for inlet and port at top for outlet. For 2-row coils, always plumb in counter flow orientation: Left hand unit's water inlet on bottom, and outlet on the top. Right hand unit’s water inlet on top and outlet on bottom.
4. Access Panel is standard.
131
Dimensional Data
LOW-HEIGHT PARALLEL ELECTRIC HEAT (LPEF) FAN SIZES 08SQ & 09SQ
FAN
INLET SIZE
AVAILABILITY
SIZE NOMINAL Ø (INCHES)
INLET SIZE
AVAILABILITY
NOMINAL Ø (mm)
08SQ
5, 6, 8 127, 152, 203
DISCHARGE DIMENSIONS
H
11.00" (279 mm)
W L
A
B
40.00" (1016 mm) 30.00" (762 mm) 19.00" (483 mm)
9.50" (241 mm)
09SQ
6, 8
152, 203
D
UNIT WT
WT LBS
(kg)
4.00" (102 mm) 104 (47.2)
109 (49.4)
09SQ
8 x 14 203 x 356
3.25" (83 mm) 118 (53.5)
Optional Attenuator
Field Installed
132
5.00"
(127 mm)
20.00"
(508 mm)
5.
Actuator, Controller and
Fan Controls located in Enclosure
D
Primary
Airflow
Valve 5"
6.50"
(165 mm)
4.00
(102 mm)
32.00"
(813 mm)
Optional Attenuator
Field Installed
Airflow
Plenum Inlet
18.00"
(457 mm)
17.50"
(445 mm)
7.
L
Heater
Airflow
Discharge Outlet
6.00"
(152 mm)
TOP VIEW
W
H
10.50"
(267 mm)
B
5.
Actuator, Controller and
Fan Controls located in Enclosure
Rectangular Damper
8" x 14"
(203 mm X 356 mm)
Rectangular Damper Detail
Fan Size
08SQ
09SQ
5.
Actuator, Controller and
Fan Controls located in Enclosure
Filter Size
10" x 20 " x 1"
(254 mm x 508 mm x 25 mm)
Atten Wt
Lbs
(kg)
10 (4.5)
NOTES:
1. Allow a minimum 6" (152 mm) plenum inlet clearance for unducted installations.
2. Flanged discharge outlet accepts up to a 1" (25 mm) duct flange.
3. Bottom Access panel standard.
4. Air valve centered between top and bottom panel.
5. Control box enclosure provided with all control types.
6. All high & low voltage controls have same-side NEC jumpback clearance. (Left-hand
shown, right-hand/mirror image optional.)
7. Flange adds 2" to width and length of unit.
A
DISCHARGE VIEW
VAV-PRC012-EN
LOW-HEIGHT PARALLEL ELECTRIC (LPEF) FAN SIZE 10SQ
Dimensional Data
VAV-PRC012-EN 133
Dimensional Data
Low Height Series Fan-Powered Terminal Units
LOW-HEIGHT SERIES COOLING ONLY (LSCF) FAN SIZES 08SQ & 09SQ
FAN
SIZE
08SQ
09SQ
09SQ
INLET SIZE
AVAILABILITY
NOMINAL Ø (inches)
5, 6, 8
6, 8
8 x 14
INLET SIZE
AVAILABILITY
NOMINAL Ø (mm)
H
11.00" (279 mm)
127, 152, 203
152, 203
203 x 355
DISCHARGE DIMENSIONS
W L
26.00" (660 mm)
A B
40.00" (1016 mm)
18.00" (457 mm) 10.00" (254 mm)
D
Unit Wt
Lbs
(kg)
4.00" (102 mm)
4.50" (114 mm)
86 (39)
96 (44)
105 (47)
Optional Attenuator
Field Installed
134
17.50"
(445 mm)
5.00"
(127 mm)
10.50"
(267 mm)
TOP VIEW
D
Primary
Airflow
Valve 5"
6.50"
(165 mm)
4.
Actuator, Controller and
Fan Controls located in Enclosure
32.00"
(813 mm)
Optional Attenuator
Field Installed
Air
Valve
4.00
(102 mm)
Airflow
Plenum Inlet
18.00"
(457 mm)
Rectangular Damper
8" x 14"
(203 mm x 356 mm)
W
Airflow
Discharge Outlet
L
B
7.
4.
Actuator, Controller and
Fan Controls located in Enclosure
Rectangular Damper Detail
4.
Actuator, Controller and
Fan Controls located in Enclosure
Fan Size
08SQ
09SQ
Filter Size
10" x 10" x 1"
(254 mm x 254 mm x 25 mm)
Atten Wt
Lbs
(kg)
10 (4.5)
NOTES:
1. Allow a minimum 6" (152 mm) plenum inlet clearance for
unducted installations.
2. Flanged discharge outlet accepts up to a 1" (25 mm) duct flange.
3. Bottom Access panel standard.
4. Control box enclosure provided with all control types.
5. Air valve centered between top and bottom panel.
6. All high & low voltage controls have same-side NEC jumpback
clearance. (Left-hand shown, right-hand/mirror image optional.)
7. Flange adds 2" to width and length of unit.
H
DISCHARGE VIEW
A
1.00"
(25 mm)
VAV-PRC012-EN
Dimensional Data
LOW-HEIGHT SERIES COOLING (LSCF) FAN SIZE 10SQ
FAN
SIZE
10SQ
INLET SIZE
AVAILABILITY
NOMINAL Ø (INCHES)
8
INLET SIZE
AVAILABILITY
NOMINAL Ø (mm)
203
H W L
11.00" (279 mm) 48.00" (1219 mm)
36.00" (914 mm)
DISCHARGE DIMENSIONS
C
A B
38.00" (965 mm)
10.00" (254 mm)
4.00" (102 mm)
D
UNIT WT
WT LBS
(kg)
20.00" (508 mm) 120 (54)
10SQ 8 x 14
203 x 356
17.50" (445 mm) 130 (59)
Optional Attenuator
Field Installed
2. Optional Attenuator
Field Installed
8.
Actuator, Controller and
Fan Controls located in Enclosure
8.
Actuator, Controller and
Fan Controls located in Enclosure
2.
18.00"
(457 mm)
32.00"
(813 mm)
Optional Attenuator
Field Installed
D
Airflow
Plenum Inlet
Primary
Airflow
C
32.00"
(813 mm)
Optional Attenuator
Field Installed
Airflow
Plenum Inlet
17.50"
(445 mm)
5.00"
(127 mm)
Rectangular Damper Detail
Rectangular Damper
8" x 14"
(203 mm x 356 mm)
L
9.
Fan Size
10SQ
Filter Size
10" x 16" x 1"
(254 mm x 406 mm x 25 mm)
Atten Wt
Lbs
(kg)
20 (9)
H B
10.50"
(267 mm)
W
Airflow
Discharge Outlet
TOP VIEW
NOTES:
1. Allow a minimum 6" (152 mm) plenum inlet clearance for
unducted installations.
2. Filter location with optional Attenuator.
3. Attenuator-factory assembled, field installed.
4. Air valve centered between top and bottom panel.
5. Heating coil uninsulated. External insulation may be field
supplied and installed as required.
6. All high & low voltage controls have same-side NEC jumback
clearance. (Left-hand shown, right-hand/mirror image optional.)
7. Bottom Access panel standard.
8. Control box enclosure provided with all control types.
9. Flange adds 2" to width and length of unit.
A
DISCHARGE VIEW
VAV-PRC012-EN 135
Dimensional Data
LOW-HEIGHT SERIES HOT WATER (LSWF) FAN SIZES 08SQ & 09SQ
FAN
SIZE
08SQ
09SQ
09SQ
INLET SIZE
AVAILABILITY
NOMINAL Ø (INCHES)
5, 6, 8
6, 8
8 x 14
INLET SIZE
AVAILABILITY
NOMINAL Ø (mm)
127, 152, 203
152, 203
203 x 355
H
11.00" (279 mm)
DISCHARGE DIMENSIONS
W L
26.00" (660 mm) 40.00" (1016 mm)
A
18.00" (457 mm)
B
10.00" (254 mm)
D
4.00" (102 mm)
4.50" (114 mm)
Unit Wt
Lbs
(kg)
95 (43)
105 (48)
114 (52)
Optional Attenuator
Field Installed
136
17.50"
(445 mm)
5.00"
(127 mm)
10.50"
(267 mm)
TOP VIEW
D
Primary
Airflow
Valve 5"
6.50"
(165 mm)
4.
Actuator, Controller and
Fan Controls located in Enclosure
32.00"
(813 mm)
Optional Attenuator
Field Installed
Air
Valve
4.00
(102 mm)
Airflow
Plenum Inlet
18.00"
(457 mm)
L
4.
Actuator, Controller and
Fan Controls located in Enclosure
Rectangular Damper
8" x 14"
(203 mm x 356 mm)
Rectangular Damper Detail
4.
Actuator, Controller and
Fan Controls located in Enclosure
Fan Size
08SQ
09SQ
Filter Size
10" x 10" x 1"
(254 mm x 254 mm x 25 mm)
Atten Wt
Lbs
(kg)
10 (4.5)
6.80"
(173 mm)
8.
Water
Coil
Airflow
Discharge Outlet
W
DISCHARGE VIEW
A
B
1.00"
(25 mm)
H
NOTES:
1. Allow a minimum 6" (152 mm) plenum inlet clearance for
unducted installations.
2. Flanged discharge outlet accepts up to a 1" (25 mm)
duct flange.
3. Bottom Access panel standard.
4. Control box enclosure provided with all control types.
5. Air valve centered between top and bottom panel.
6. Heating coil uninsulated. External insulation may be field
supplied and installed as required.
7. All high & low voltage controls have same-side NEC
jumpback clearance. (Left-hand shown, right-hand/mirror
image optional.)
8. Flange adds 2" to width and length of unit.
VAV-PRC012-EN
Dimensional Data
LOW-HEIGHT SERIES HOT WATER (LSWF) FAN SIZE 10SQ
FAN
SIZE
INLET SIZE
AVAILABILITY
NOMINAL Ø (INCHES)
10SQ 8
10SQ 8 x 14
INLET SIZE
AVAILABILITY
NOMINAL Ø (mm)
203
DISCHARGE DIMENSIONS
H W L C
11.00" (279 mm)
A B
48.00" (1219 mm) 36.00" (914 mm) 38.00" (965 mm) 10.00" (254 mm) 4.00" (102 mm)
203 x 356
D
20.00" (508 mm)
UNIT WT
WT LBS
(kg)
136 (62)
17.50" (445 mm) 146 (66)
Optional Attenuator
Field Installed
2.
Optional Attenuator
Field Installed
8.
Actuator, Controller and
Fan Controls located in Enclosure
8.
Actuator, Controller and
Fan Controls located in Enclosure
18.00"
(457 mm)
32.00"
(813 mm)
Optional Attenuator
Field Installed
D
Airflow
Plenum Inlet
10.50"
(267 mm)
17.50"
(445 mm)
5.00"
(127 mm)
2.
Primary
Airflow
C
32.00"
(813 mm)
Optional Attenuator
Field Installed
Airflow
Plenum Inlet
W
Airflow
Discharge Outlet
TOP VIEW
B
L
9.
6.80"
(173 mm)
Rectangular Damper Detail
Rectangular Damper
8" x 14"
(203 mm x 356 mm)
Fan Size
10SQ
Filter Size
8.
Actuator, Controller and
Fan Controls located in Enclosure
10" x 16" x 1"
(254 mm x 406 mm x 25 mm)
Atten Wt
Lbs
(kg)
20 (9)
H
NOTES:
1. Allow a minimum 6" (152 mm) plenum inlet clearance for
unducted installations.
2. Filter location with optional Attenuator.
3. Attenuator-factory assembled, field installed.
4. Air valve centered between top and bottom panel.
5. Heating coil uninsulated. External insulation may be field
supplied and installed as required.
6. All high & low voltage controls have same-side NEC
jumpback clearance. (Left-hand shown, right-hand/mirror
image optional.)
7. Bottom Access panel standard.
8. Control box enclosure provided with all control types.
9. Flange adds 2" to width and length of unit.
A
DISCHARGE VIEW
VAV-PRC012-EN 137
Dimensional Data
138 VAV-PRC012-EN
Dimensional Data
VAV-PRC012-EN 139
Dimensional Data
LOW-HEIGHT SERIES ELECTRIC HEAT (LSEF) FAN SIZES 08SQ & 09SQ
FAN
SIZE
08SQ
09SQ
09SQ
INLET SIZE
AVAILABILITY
NOMINAL Ø (INCHES)
5, 6, 8
6, 8
8 x 14
INLET SIZE
AVAILABILITY
NOMINAL Ø (mm)
127, 152, 203
152, 203
203 x 355
H
11.00" (279 mm)
W
26.00" (660 mm)
DISCHARGE DIMENSIONS
L
A
40.00" (1016 mm) 14.00" (356 mm)
B
9.00" (229 mm)
D
4.00" (102 mm)
4.50" (114 mm)
Unit Wt
Lbs
(kg)
101 (45.8)
111 (50.3)
120 (54.4)
Optional Attenuator
Field Installed
140
17.50"
(445 mm)
5.00"
(127 mm)
10.50"
(267 mm)
20.00"
(508 mm)
D
Primary
Airflow
Valve 5"
6.50"
(165 mm)
4.
Actuator, Controller and
Fan Controls located in Enclosure
32.00"
(813 mm)
Optional Attenuator
Field Installed
Air
Valve
4.00
(102 mm)
Airflow
Plenum Inlet
18.00"
(457 mm)
Electric
Heater
Airflow
Discharge Outlet
20.00"
(508 mm)
A
4.
Actuator, Controller and
Fan Controls located in Enclosure
L
8.
Rectangular Damper
8" x 14"
(203 mm x 356 mm)
Rectangular Damper Detail
Fan Size
08SQ
09SQ
Filter Size
4.
Actuator, Controller and
Fan Controls located in Enclosure
10" x 10" x 1"
(254 mm x 254 mm x 25 mm)
Atten Wt
Lbs
(kg)
10 (4.5)
B
TOP VIEW
H
NOTES:
1. Allow a minimum 6" (152 mm) plenum inlet clearance for unducted installations.
2. Flanged discharge outlet accepts up to 1" (25 mm) duct flange.
3. Bottom Access panel standard.
4. Control box enclosure provided with all control types.
5. Air valve centered between top and bottom panel.
6. Heating coil uninsulated. External insulation may be field supplied and
installed as required.
7. All hight & low voltage controls have same-side NEC jumpback clearance.
(Left-hand shown, right-hand/mirror image optional.)
8. Flange adds 2" to width and length of unit.
DISCHARGE VIEW
VAV-PRC012-EN
Dimensional Data
LOW-HEIGHT SERIES ELECTRIC (LSEF) FAN SIZE 10SQ
FAN
SIZE
10SQ
INLET SIZE
AVAILABILITY
NOMINAL Ø (INCHES)
8
INLET SIZE
AVAILABILITY
NOMINAL Ø (mm)
203
H W
11.00" (279 mm) 48.00" (1219 mm)
10SQ
8 x14 203 x 356
L
36.00" (914 mm)
DISCHARGE DIMENSIONS
A
B
19.00" (483 mm) 9.50" (241 mm)
C
4.00" (102 mm)
D
UNIT WT
WT LBS
(kg)
20.00" (508 mm) 145 (65.8)
17.50" (445 mm)
155 (70.3)
Optional Attenuator
Field Installed
18.00"
(457 mm)
17.50"
(445 mm)
5.00"
(127 mm)
32.00"
(813 mm)
Optional Attenuator
Field Installed
D
Airflow
Plenum Inlet
2.
Optional Attenuator
Field Installed
8.
Actuator, Controller and
Fan Controls located in Enclosure
8.
Actuator, Controller and
Fan Controls located in Enclosure
2.
Primary
Airflow
C
Airflow
Plenum Inlet
32.00"
(813 mm)
Optional Attenuator
Field Installed
W
L
9.
Rectangular Damper Detail
Rectangular Damper
8" x 14"
(203 mm x 356 mm)
8.
Actuator, Controller and
Fan Controls located in Enclosure
Fan Size
10SQ
Filter Size
10" x 16" x 1"
(254 mm x 406 mm x 25 mm)
Atten Wt (Qty 2)
Lbs
(kg)
20 (9.1)
24.00"
(610 mm)
Heater
Plenum Area
11.00"
(279 mm)
8.00"
(203 mm)
Airflow
Discharge Outlet
TOP VIEW
NOTES:
1. Allow a minimum 6" (152 mm) plenum inlet clearance for
unducted installations.
2. Filter location with optional Attenuator.
3. Attenuator-factory assembled, field installed.
4. Air valve centered between top and bottom panel.
5. Heating coil uninsulated. External insulation may be field supplied
and installed as required.
6. All high & low voltage controls have same-side NEC jumpback
clearance. (Left-hand shown, right-hand/mirror image optional.)
7. Bottom Access panel standard.
8. Control box enclosure provided with all control types.
9. Flange adds 2" to width and length of unit.
H B
10.50"
(267 mm)
A
DISCHARGE VIEW
VAV-PRC012-EN 141
advertisement
Related manuals
advertisement
Table of contents
- 5 Features and Benefits
- 13 Agency Certifications
- 15 Model Number Descriptions
- 17 Selection Procedure
- 17 Air Valve Selection
- 17 Heating Coil Selection
- 18 Fan Size and Selection
- 18 Acoustics
- 19 Selection Example—Parallel With Hot Water Heat
- 22 Selection Example—Series With Hot Water Heat and ECM
- 24 Performance Data
- 24 Parallel Fan-Powered Terminal Units
- 32 Water Coil Performance Notes (I-P)
- 34 Water Coil Performance Notes (SI)
- 35 Series Fan-Powered Terminal Units
- 44 Water Coil Notes (I-P)
- 46 Water Coil Notes (SI)
- 47 Low Height Parallel Fan-Powered Terminal Units
- 49 Performance Data Fan Curves
- 53 Low Height Series Fan-Powered Terminal Units
- 59 Electrical Data
- 59 Parallel Fan-Powered Terminal Units
- 63 Series Fan-Powered Terminal Units
- 68 Low Height Parallel Fan-Powered Terminal Units
- 70 Low Height Series Fan-Powered Terminal Units
- 73 Fan-Powered Parallel
- 74 Fan-Powered Series
- 75 Low Height Parallel Fan-Powered
- 75 Low-Height Series Fan-Powered
- 76 Acoustics Data
- 76 Parallel Fan-Powered Terminal Units
- 85 Series Fan-Powered Terminal Units
- 92 Low Height Parallel Fan-Powered Terminal Units
- 98 Low Height Series Fan-Powered Terminal Units
- 103 Dimensional Data
- 103 Parallel Fan-Powered Terminal Units
- 109 Series Fan-Powered Terminal Units
- 123 Low Height Parallel Fan-Powered Terminal Units
- 128 Coil Information For Low Height Parallel Inlet-1 Row
- 129 Coil Information For Low Height Parallel Plenum Inlet 2-Row Coil
- 130 Coil Information For Low Height Parallel Discharge 1-Row Coil
- 131 Coil Information For Low Height Parallel Discharge 2 Row Coil
- 134 Low Height Series Fan-Powered Terminal Units
- 142 Mechanical Specifications: Fan-Powered
- 147 DDC Controls
- 147 Control Logic
- 148 DDC Remote Heat Control Options
- 152 Tracer™ UC400 and UC210 Programmable BACnet Controllers
- 152 General Features and Benefits
- 154 Trane DDC VAV Controller Logic
- 157 Flow Tracking Control
- 158 Tracer™ Programmable BACnet Controller — Unit Control Module
- 159 Specifications
- 160 Trane LonMark DDC VAV Controller
- 160 Introduction
- 160 General Features and Benefits
- 162 Trane DDC VAV Controller Logic
- 165 Flow Tracking Control
- 166 LonMark™ Direct Digital Controller—Unit Control Module
- 166 Specifications
- 169 Direct Digital Controller—Unit Control Module
- 169 Specifications
- 170 Wireless Comm Interface (WCI)
- 171 Dimensions
- 171 Specifications
- 172 Wireless Receiver/Wireless Zone Sensor
- 172 Specifications
- 173 DDC Zone Sensor
- 173 Specifications
- 174 CO2 Wall Sensor and Duct CO2 Sensor
- 174 Specifications
- 176 DDC Zone Sensor with LCD
- 176 Specifications
- 177 Zone Occupancy Sensor
- 177 Specifications
- 178 Factory or Field Wired Auxiliary Temperature Sensor
- 178 Specifications
- 178 Control Relay
- 178 Specifications
- 179 Two-Position Water Valve
- 179 Specifications
- 180 Proportional Water Valve
- 180 Specifications
- 181 Differential Pressure Transducer
- 181 Specifications
- 182 Transformers
- 182 Specifications
- 183 Trane Actuator – 90 Second at 60 Hz Drive Time
- 183 Specifications
- 184 Belimo Actuator – 95 Second Drive Time
- 184 Specifications
- 185 Trane Spring Return Actuator
- 185 Specifications
- 186 VariTrane DDC Retrofit Kit
- 186 Retrofit Kit Actuator
- 186 Specifications
- 187 Silicon-Controlled Rectifier (SCR)
- 188 Pneumatic Controls
- 188 3011 Pneumatic Volume Regulator
- 189 3501 Pneumatic Volume Regulator
- 190 Pneumatic Damper Actuator
- 191 Reversing Relay
- 192 Signal Limiter
- 203 Controls Specifications
- 203 Fan Speed Control
- 203 Direct Digital Controls (DDC)
- 206 Pneumatic Controls
- 207 Options
- 207 DDC Retrofit Kit (VRTO)
- 207 Retrofit Kit Options
- 207 Other Options Available
- 208 Application Considerations
- 208 VAV System
- 208 No Heat
- 208 Central Heat
- 209 Terminal Heat
- 209 VariTrane VAV Terminal Units
- 210 VAV Terminal Unit Types
- 211 Parallel vs. Series
- 211 Comparison of Parallel and Series Models
- 211 Typical Application of Parallel Units
- 211 Typical Application of Series Units
- 213 Low-Temperature Air
- 213 Benefits of Low-Temperature Air
- 213 System Operation
- 214 Considerations for VAV products
- 216 Energy Savings & System Controls
- 216 Electrically Commutated Motor
- 216 Fan-Pressure Optimization
- 217 Ventilation Reset
- 218 Control Types
- 218 Direct Digital Control (DDC) Systems
- 218 Pneumatic Control Systems
- 219 DDC Controls Basic Information
- 219 Pneumatic Controls Basic Information
- 219 Room Thermostats
- 220 Pneumatic Volume Regulators
- 221 Flow Measurement and Control
- 221 Flow Measurement
- 222 Accuracy
- 223 Air Density Effects
- 224 Reheat Options
- 225 Electric Reheat
- 226 Insulation
- 226 Acoustics
- 230 Duct Design
- 231 Best Practices
- 231 Common Mistakes
- 232 Unit Conversions
- 233 Additional VAV System and Product References