10.1 Illustrated Parts. Ohio Medical Push-To-Set Continuous Vacuum Regulator

10.1 Illustrated Parts. Ohio Medical Push-To-Set Continuous Vacuum Regulator
Add to My manuals

Below you will find brief information for Vacuum Regulator Push-To-Set Continuous Vacuum Regulator. The Push-To-Set Continuous Vacuum Regulator is a lightweight, compact unit used throughout the hospital primarily for pharyngeal/tracheal suctioning (airway management). Various models provide regulated or full-line vacuum for hospital suction procedures.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

10.1 Illustrated Parts. Ohio Medical Push-To-Set Continuous Vacuum Regulator | Manualzz

10.1 Illustrated Parts

10/Ordering Information

Item

6

7

8

9

10

1

2

3

4

5

11

12

13

14

Part Number

6700-0078-400

8700-0017-500

See Table

8700-0041-500

8700-0021-500

See table below

8700-0038-500

8700-0015-500

6700-0175-500

8700-0002-700

8700-0043-500

8700-0001-700

0210-0525-300

8700-0040-500

Description

Screw, PHH PNH, 4-20 Plastite

Knob

Case, Regulator

Gauge Lens

Drive Gear, Occlude-To-Set

Gauge, Vacuum

Cover Strip, Switch

Actuator, Occlude-To-Set

O-Ring, 2-013 Nitrile

OTS Assembly

Support Bracket, Actuator

Assembly, Reg Mod

O-Ring, 9.32 OD x 5.32 IS x 1/16 W

Plate, Detent

Qty

1

1

1

1

1

5

1

1

1

1

1

1

1

1

Item

20

21

22

23

24

15

16

17

18

19

25

26

27

Part Number

8700-0016-500

See table below

See table below

See table below

6700-0115-400

0206-5159-300

6700-0121-400

8700-0009-700

6700-0151-400

8700-0016-100

8700-0005-100

8700-0056-500

See table below

Description

Selector Switch, Overmolded

Plug, Pull Tab

Vacuum Relief Assembly

O-Ring, 2-014, Nitrile, Buna-N

Relief Valve, Positive Pressure

Plug, Filter

Orifi ce, Continuous Vacuum Regulator

Manifold Assembly

Screw, Self Tap, #6 Pan Head

Serial Number Label

Knob, Label

Plug

Label

Qty

1

1

1

4

1

1

1

1

1

1

1

1

1

Model #

1224

1225

1226

1227

1231

1234

1330

8700-0006-000 Rev.3

Item 3

Case, Regulator

8700-0012-500

8700-0022-500

8700-0012-500

8700-0022-500

8700-0053-500

8700-0053-500

8700-0022-500

Item 16

Plug, Pull Tab

8700-0039-500

8700-0039-500

8700-0039-500

N/A

N/A

N/A

8700-0039-500

Item 6

Vacuum Gauge, Analog

Range

0-200 mmHg

0-760 mmHg

0-160 mmHg

P/N

8700-0002-400

8700-0022-400

8700-0024-400

Item 17

Vacuum Relief Assembly

N/A

N/A

N/A

6700-0045-700

6700-0045-700

6700-0045-700

N/A

Item 18 O-Ring, 2-014,

Nitrille, Buna-N

N/A/

N/A

N/A

6700-0135-500

6700-0135-500

6700-0135-500

N/A/

Item 27

Label

N/A

N/A

N/A

8700-0036-101

8700-0036-102

N/A

N/A

Range

0-160 mmHg

0-200 mmHg

0-650 mmHg

Item 6

Vacuum Gauge, Digital

Replacement Battery

P/N

VR-DGP-160MM

VR-DGP-200MM

VR-DGP-760MM

VR-DGP-BAT

20

North America

United States

Customer Service and Distribution Center

Technical Suopport

Sales and Services

Equipment Service Center

Ohio Medical Corporation

1111 Lakeside Drive

Gurnee, IL 60031-4099, USA

Tollfree: 866-549-6446

Phone: 847-855-0800

Fax: 847-655-6218 www.ohiomedical.com

1111 Lakeside Drive

Gurnee, IL 60031-4099, USA

Tollfree: 866-549-6446

Phone: 847-855-0800

Fax: 847-655-6218 www.ohiomedical.com

21

8700-0006-000 (Rev.3)

01/2009

8700-0006-000 Rev.3

advertisement

Key Features

  • Lightweight and compact
  • Provides regulated or full-line vacuum
  • Includes vacuum gauge
  • Features positive pressure safety relief valve
  • Low models have vacuum relief valve to limit maximum suction
  • Operates in regulated or non-regulated mode
  • Automatically adjusts suction level
  • Easy to use and adjust
  • Safe and reliable

Frequently Answers and Questions

What is the purpose of the Push-To-Set Continuous Vacuum Regulator?
The Push-To-Set Continuous Vacuum Regulator is used to provide suction for various medical procedures, primarily for pharyngeal/tracheal suctioning (airway management).
How do I set the suction level on the Push-To-Set Continuous Vacuum Regulator?
To set the suction level, turn the mode selector switch to "I" (On) and rotate the suction control knob until the vacuum gauge indicates the desired setting.
What is the difference between the regulated and non-regulated modes on the Push-To-Set Continuous Vacuum Regulator?
In the non-regulated (MAX) mode, the vacuum source is connected directly to the fitting port, providing full-line vacuum. In the regulated mode, the vacuum source is connected through the regulator module, which functions as an automatic valve to control the suction level.
How do I clean the Push-To-Set Continuous Vacuum Regulator?
Routine cleaning is recommended after each use. Wipe all exterior surfaces with a solution of water and mild detergent. If the regulator becomes flooded with patient fluid, all internal components (except the gauge) can be cleaned with a solution of warm water and mild detergent. Dry all components thoroughly before assembly.
How do I sterilize the Push-To-Set Continuous Vacuum Regulator?
The only acceptable method of sterilization is with gas (ethylene oxide). Follow the sterilization instructions provided in the manual carefully.

Related manuals

Download PDF

advertisement

Table of contents