Below you will find brief information for RAV-SM560 AT-E, RAV-SM800 AT-E, RAV-SM560 UT-E, RAV-SM800 UT-E, RAV-SM560 BT-E, RAV-SM800 BT-E, RAV-SM560 KRT-E, RAV-SM800 KRT-E, RAV-SM560 XT-E, RAV-SM800 XT-E. These split-system air conditioners are designed to provide comfortable indoor temperatures in residential and commercial settings. The units are available in a range of capacities to suit different needs and come with various features for optimal performance and energy efficiency.

advertisement

SPECIFICATIONS. Toshiba RAV-SM560 BT-E, RAV-SM560 XT-E, RAV-SM560 KRT-E, RAV-SM800 AT-E, RAV-SM800 KRT-E, RAV-SM800 BT-E, RAV-SM800 XT-E, RAV-SM560 UT-E, RAV-SM560 AT-E, RAV-SM800 UT-E | Manualzz

Toshiban lämmitys- ja jäähdytyslaitteiden jälleenmyyjä pääkaupunkiseudulla on Jäähdytinpalvelu RefGroup Oy

1. SPECIFICATIONS

1-1. Indoor Unit

1-1-1. 4-Way Air Discharge Cassette Type

Model name

Standard capacity (Note 1) (kW)

Heating low temp. capacity (Note 1) (kW)

Energy consumption effect ratio (Cooling)

Power supply

Running current

Electrical characteristics

Power consumption

(Low temp.)

Appearance

Outer dimension

Power factor

Main unit

Ceiling Panel

(Sold separately)

Model

Panel color

Main unit

Height

Width

Depth

Height

Ceiling panel

(Sold separately)

Width

Depth

Total weight

Main unit

Ceiling panel

Heat exchanger

Soundproof/Heat-insulating material

Fan

Fan unit Standard air flow High (Mid./Low) (m³/h)

Motor (W)

Air filter

Controller (Sold separately)

Connecting pipe

Sound level

Gas side

Liquid side

Drain port

High (Mid./Low) (Note 2)

(mm)

(mm)

(Nominal dia.)

(dB•A)

(mm)

(mm)

(mm)

(mm)

(mm)

(mm)

(kg)

(A)

(kW)

(kW)

(%)

Cooling

RAV-SM560UT-E

Heating Average Cooling

RAV-SM800UT-E

Heating Average

5.3

5.6

(1.5 – 5.6) (1.5 – 6.3)

3.01 [B]

7.1

(2.2 – 8.0)

8.0

(2.2–9.0)

4.9

3.90 [A] 3.46

3.03 [B]

1 phase 230V (220 – 240V) 50Hz

7

3.45 [B]

8.42–7.72

6.78–6.29

1.76

1.435

1.89

11.32–10.37 11.22–10.28

2.34

2.73

2.32

3.24

95 95 94

Zinc hot dipping steel plate

RBC-U21PG (W) E

Moon-white (Muncel 2.5GY 9.0/0.5)

94

256

840

840

53

950

950

21 22

4.5

Finned tubu

Inflammable polyethylene foam

Turbo fan

Foamed polyethylen

32

1050 1200

60

Attached ceiling panel

RBC-AMT21E

Ø12.7 (1/2”)

Ø6.4 (1/4”)

29

25 (Polyvinyl chloride tube)

27 34

Ø15.9 (5/8”)

Ø9.5 (3/8”)

31 28

Note 1 : The cooling capacities and electrical characteristics are measured under the conditions speciied by JIS B 8616 based on the reference piping. The reference piping consists of 3 m of main piping and 2 m of branch piping connected with 0 meter height.

Note 2 : The sound level is measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound.

Note

: Rated conditions Cooling : Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB

Heating : Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB

– 3 – www.ilmalämpöpumput.com

Toshiban lämmitys- ja jäähdytyslaitteiden jälleenmyyjä pääkaupunkiseudulla on Jäähdytinpalvelu RefGroup Oy

• Operation characteristic curve

<Cooling>

14

12

10

RAV-SM800UT-E

8

6

4

2

0

0

RAV-SM560UT-E

Conditions

Indoor : DB27 C/WB19 C

Outdoor : DB35 C

Air flow : High

Pipe length : 7.5m

230V

15

20 40 60 70 80

Compressor speed (rps)

100

<Heating>

16

14

12

10

8

6

4

2

0

0

RAV-SM800UT-E

RAV-SM560UT-E

• Conditions

Indoor : DB20 C

Outdoor : DB7 C/WB6 C

Air flow : High

Pipe length : 7.5m

230V

15

20 40 60

Compressor speed (rps)

80 90 100

• Capacity variation ratio according to temperature

<Cooling> <Heating>

105

100

95

90

85

80

75

70

65

60

55

• Conditions

Indoor : DB27 C/WB19 C

Indoor air flow : High

Pipe length : 7.5m

50

32 33 34 35 36 37 38 39 40 41 42 43

Outsoor temp. ( C)

120

110

100

90

80

70

60

50

40

30

20

10

• Conditions

Indoor : DB20 C

Indoor air flow : High

Pipe length : 7.5m

0

-14 -12 -10 -8 -6 -4 -2 0 2 4 6 8 10

Outsoor temp. ( C)

– 4 – www.ilmalämpöpumput.com

Toshiban lämmitys- ja jäähdytyslaitteiden jälleenmyyjä pääkaupunkiseudulla on Jäähdytinpalvelu RefGroup Oy

1-1-2. Concealed Duct Type

Model name

Standard capacity (Note 1) (kW)

Heating low temp. capacity (Note 1) (kW)

Energy consumption effect ratio (Cooling)

Power supply

Running current

Electrical characteristics

Power consumption

(Low temp.)

Power factor

Main unit

Appearance

Ceiling Panel

(Sold separately)

Model

Panel color

Height

Main unit Width

Outer dimension

Total weight

Depth

Height

Ceiling panel

(Sold separately)

Width

Depth

Main unit

Ceiling panel

Heat exchanger

Soundproof/Heat-insulating material

Fan

Fan unit Standard air flow High (Mid./Low) (m³/h)

Motor (W)

(mm)

(mm)

(mm)

(mm)

(mm)

(mm)

(kg)

(A)

(kW)

(kW)

(%)

Air filter

Controller (Sold separately)

Connecting pipe

Sound level

Gas side

Liquid side

Drain port

High (Mid./Low) (Note 2)

(mm)

(mm)

(Nominal dia.)

(dB•A)

Cooling

RAV-SM560BT-E

Heating Average Cooling

RAV-SM800BT-E

Heating Average

5 5.6

(1.5 – 5.6) (1.5 – 6.3)

7.1

(2.2 – 8.0)

8

(2.2–9.0)

4.6

3.27 [C]

6.2

3.21 [C] 2.60 [D] 2.94

2.73 [D]

1 phase 230V (220 – 240V) 50Hz

9.19–8.42

8.18–7.50

12.57–11.52 12.04–11.04

1.92

1.71

2.6

2.49

95

1.78

2.62

95 94

Zinc hot dipping steel plate

94

2.97

——

——

320

700

800 (+7.5)

——

——

——

39 53

——

Finned tubu

Inflammable polyethylene foam

Turbo fan

Foamed polyethylen

840

60

1140

100

42

Attached main unit

RBC-AMT21E

Ø12.7 (1/2”)

Ø6.4 (1/4”)

39

25 (Polyvinyl chloride tube)

36 43

Ø15.9 (5/8”)

Ø9.5 (3/8”)

40 37

Note 1 : The cooling capacities and electrical characteristics are measured under the conditions speciied by JIS B 8616 based on the reference piping. The reference piping consists of 3 m of main piping and 2 m of branch piping connected with 0 meter height.

Note 2 : The sound level is measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound.

Note

: Rated conditions Cooling : Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB

Heating : Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB

– 5 – www.ilmalämpöpumput.com

Toshiban lämmitys- ja jäähdytyslaitteiden jälleenmyyjä pääkaupunkiseudulla on Jäähdytinpalvelu RefGroup Oy

Operation characteristic curve

<Cooling>

14

12

10

RAV-SM800BT-E

8

6

4

2

0

0

RAV-SM560BT-E

• Conditions

Indoor : DB27 C/WB19 C

Outdoor : DB35 C

Air flow : High

Pipe length : 7.5m

230V

15

20 40 60 70 80

Compressor speed (rps)

100

<Heating>

16

14

12

10

8

6

4

2

0

0

RAV-SM800BT-E

RAV-SM560BT-E

• Conditions

Indoor : DB20 C

Outdoor : DB7 C/WB6 C

Air flow : High

Pipe length : 7.5m

230V

15

20 40 60

Compressor speed (rps)

80 90 100

Capacity variation ratio according to temperature

<Cooling> <Heating>

105

100

95

90

85

80

75

70

65

60

55

• Conditions

Indoor : DB27 C/WB19 C

Indoor air flow : High

Pipe length : 7.5m

50

32 33 34 35 36 37 38 39 40 41 42 43

Outsoor temp. ( C)

120

110

100

90

80

70

60

50

40

30

20

10

• Conditions

Indoor : DB20 C

Indoor air flow : High

Pipe length : 7.5m

0

-14 -12 -10 -8 -6 -4 -2 0 2 4 6 8 10

Outsoor temp. ( C)

– 6 – www.ilmalämpöpumput.com

Toshiban lämmitys- ja jäähdytyslaitteiden jälleenmyyjä pääkaupunkiseudulla on Jäähdytinpalvelu RefGroup Oy

1-1-3. High-Wall Type

Model name

Standard capacity (Note 1) (kW)

Heating low temp. capacity (Note 1) (kW)

Energy consumption effect ratio (Cooling)

Power supply

Running current

Electrical characteristics

Power consumption

(Low temp.)

Power factor

Main unit

Appearance

Ceiling Panel

(Sold separately)

Model

Panel color

Height

Main unit Width

Depth

Outer dimension

Total weight

Height

Ceiling panel

(Sold separately)

Width

Depth

Main unit

Ceiling panel

Heat exchanger

Soundproof/Heat-insulating material

Fan unit

Fan

Standard air flow High (Mid./Low) (m³/h)

Motor (W)

Air filter

Controller (Sold separately)

Connecting pipe

Sound level

Gas side

Liquid side

Drain port

High (Mid./Low) (Note 2)

(mm)

(mm)

(Nominal dia.)

(dB•A)

(A)

(kW)

(kW)

(%)

(mm)

(mm)

(mm)

(mm)

(mm)

(mm)

(kg)

Cooling

RAV-SM560KRT-E

Heating Average Cooling

RAV-SM800KRT-E

Heating Average

5.1

5.6

(1.5 – 5.6) (1.5 – 6.3)

6.7

(2.2 – 8.0)

8

(2.2–9.0)

4.9

3.29 [C]

5.8

3.00 [D] 2.93 [D] 3.11

2.46 [E]

1 phase 230V (220 – 240V) 50Hz

8.33–7.63

8.138–7.46

13.15–12.05 12.91–11.84

1.74

1.7

2.72

2.67

1.95

2.21

3.24

95 95 94 94

Pure white

——

——

298

45

998

208

——

——

——

12

——

Finned tubu

Inflammable polyethylene foam Foamed polyethylen

Turbo fan

840 1110

30

Attached main unit

Wired remote controller RBC-AMT21E

Ø12.7 (1/2”)

Ø6.4 (1/4”)

41

25 (Polyvinyl chloride tube)

36 45

Ø15.9 (5/8”)

Ø9.5 (3/8”)

41 36

Note 1 : The cooling capacities and electrical characteristics are measured under the conditions speciied by JIS B 8616 based on the reference piping. The reference piping consists of 3 m of main piping and 2 m of branch piping connected with 0 meter height.

Note 2 : The sound level is measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound.

Note

: Rated conditions Cooling : Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB

Heating : Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB

– 7 – www.ilmalämpöpumput.com

Toshiban lämmitys- ja jäähdytyslaitteiden jälleenmyyjä pääkaupunkiseudulla on Jäähdytinpalvelu RefGroup Oy

• Operation characteristic curve

<Cooling>

14

12

10

RAV-SM800KRT-E

8

6

4

2

0

0

RAV-SM560KRT-E

Conditions

Indoor : DB27 C/WB19 C

Outdoor : DB35 C

Air flow : High

Pipe length : 7.5m

230V

15

20 40 60 70 80

Compressor speed (rps)

100

<Heating>

16

14

12

10

8

6

4

2

0

0

RAV-SM800KRT-E

RAV-SM560KRT-E

• Conditions

Indoor : DB20 C

Outdoor : DB7 C/WB6 C

Air flow : High

Pipe length : 7.5m

230V

15

20 40 60

Compressor speed (rps)

80 90 100

• Capacity variation ratio according to temperature

<Cooling> <Heating>

105

100

95

90

85

80

75

70

65

60

55

• Conditions

Indoor : DB27 C/WB19 C

Indoor air flow : High

Pipe length : 7.5m

50

32 33 34 35 36 37 38 39 40 41 42 43

Outsoor temp. ( C)

120

110

100

90

80

70

60

50

40

30

20

10

• Conditions

Indoor : DB20 C

Indoor air flow : High

Pipe length : 7.5m

0

-14 -12 -10 -8 -6 -4 -2 0 2 4 6 8 10

Outsoor temp. ( C)

– 8 – www.ilmalämpöpumput.com

Toshiban lämmitys- ja jäähdytyslaitteiden jälleenmyyjä pääkaupunkiseudulla on Jäähdytinpalvelu RefGroup Oy

1-1-4. Flexible Type

Model name

Standard capacity (Note 1) (kW)

Heating low temp. capacity (Note 1) (kW)

Energy consumption effect ratio (Cooling)

Power supply

Running current

Electrical characteristics

Power consumption

(Low temp.)

Power factor

Appearance

Main unit

Ceiling Panel

(Sold separately)

Model

Panel color

Outer dimension

Total weight

Height

Width Main unit

Depth

Height

Ceiling panel

(Sold separately)

Width

Depth

Main unit

Ceiling panel

Heat exchanger

Soundproof/Heat-insulating material

Fan

Fan unit Standard air flow High (Mid./Low) (m³/h)

Motor (W)

Air filter

Controller (Sold separately)

Gas side

Connecting pipe

Liquid side

Drain port

Sound level High (Mid./Low) (Note 2)

(mm)

(mm)

(Nominal dia.)

(dB•A)

(A)

(kW)

(kW)

(%)

(mm)

(mm)

(mm)

(mm)

(mm)

(mm)

(kg)

Cooling

RAV-SM560XT-E

Heating Average Cooling

RAV-SM800XT-E

Heating Average

5.1

(1.5 – 5.6)

5.6

(1.5 – 6.3)

4.9

6.7

(2.2 – 8.0)

8

(2.2–9.0)

5.8

3.24

2.93 [D]

1.95

3.29 [C] 3.11

2.46 [E]

1 phase 230V (220 – 240V) 50Hz

3.00 [D]

8.33–7.63

8.138–7.46

1.74

1.7

13.15–12.05 12.91–11.84

2.72

2.21

2.67

95 95 94 94

Pure white

——

——

298

998

208

——

39

——

——

12

——

Finned tubu

Inflammable polyethylene foam

Cross flow fan

Foamed polyethylen

840 1110

30

Attached main unit

Wired remote controller RBC-AMT21E

Ø12.7 (1/2”) Ø15.9 (5/8”)

Ø6.4 (1/4”)

25 (Polyvinyl chloride tube)

Ø9.5 (3/8”)

36 36 45 41 36

Note 1 : The cooling capacities and electrical characteristics are measured under the conditions speciied by JIS B 8616 based on the reference piping. The reference piping consists of 3 m of main piping and 2 m of branch piping connected with 0 meter height.

Note 2 : The sound level is measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound.

Note

: Rated conditions Cooling : Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB

Heating : Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB

– 9 – www.ilmalämpöpumput.com

Toshiban lämmitys- ja jäähdytyslaitteiden jälleenmyyjä pääkaupunkiseudulla on Jäähdytinpalvelu RefGroup Oy

Operation characteristic curve

<Cooling>

14

12

10

8

RAV-SM800XT-E

6

4

2

0

0

RAV-SM560XT-E

• Conditions

Indoor : DB27 C/WB19 C

Outdoor : DB35 C

Air flow : High

Pipe length : 7.5m

230V

15

20 40 60 70 80

Compressor speed (rps)

100

<Heating>

14

12

10

8

6

4

2

0

0

RAV-SM800XT-E

RAV-SM560XT-E

• Conditions

Indoor : DB20 C

Outdoor : DB7 C/WB6 C

Air flow : High

Pipe length : 7.5m

230V

15

20 40 60

Compressor speed (rps)

80 90 100

Capacity variation ratio according to temperature

<Cooling> <Heating>

105

100

95

90

85

80

75

70

65

60

55

• Conditions

Indoor : DB27 C/WB19 C

Indoor air flow : High

Pipe length : 7.5m

50

32 33 34 35 36 37 38 39 40 41 42 43

Outsoor temp. ( C)

120

110

100

90

80

70

60

50

40

30

20

10

• Conditions

Indoor : DB20 C

Indoor air flow : High

Pipe length : 7.5m

0

-14 -12 -10 -8 -6 -4 -2 0 2 4 6 8 10

Outsoor temp. ( C)

– 10 – www.ilmalämpöpumput.com

Toshiban lämmitys- ja jäähdytyslaitteiden jälleenmyyjä pääkaupunkiseudulla on Jäähdytinpalvelu RefGroup Oy

1-2. Outdoor Unit

Model name

Appearance

Power supply

Compressor

Type

Motor

Pole

Refrigerant charged

Refrigerant control

Standard length

Pipe

Max. total length

Over 20m

Outer dimension

(kW)

(kg)

(m)

Height difference

Outdoor lower

Outdoor higher

Height

Width

(m)

(m)

(mm)

(mm)

Total weight

Heat exchanger

Fan unit

Connecting pipe

Protection device

Depth

Fan

Standard air flow High

Motor

Gas side

Liquid side

(mm)

(kg)

(m

³

/h)

(W)

(mm)

(mm)

RAV-SM560AT-E RAV-SM800AT-E

Silky shade (Muncel 1Y8.5/0.5)

1 phase 230V (220 – 240V) 50Hz

(Power exclusive to outdoor is required.)

Hermetic compressor

1.1

1.6

4 poles

R410A 0.9

R410A 1.5

Pulse motor valve

20 (without additional charge)

30

Add 20g/m (Max. 200g)

50

Add 40g/m (Max. 1200g)

30

50

595

780

795

780

270

35

270

55

Finned tube

Propeller fan

2400

43

Ø12.7 (1/2”)

Ø6.4 (1/4”)

3400

63

Ø15.9 (5/8”)

Ø9.5 (3/8”)

Discharge temp. sensor

Over-current sensor

Compressor thermo.

Sound level

(Note 2)

High (Mid./Low)

(Cooling/Heating)

(dB•A) 46/48 45/50

Note 1 : The cooling capacities and electrical characteristics are measured under the conditions speciied by JIS B 8616 based on the reference piping. The reference piping consists of 3 m piping connected with 0 meter height.

Note 2 : The sound level is measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound.

Note

: Rated conditions Cooling : Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB

Heating : Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB

– 11 – www.ilmalämpöpumput.com

advertisement

Key Features

  • 4-Way Air Discharge Cassette Type
  • Concealed Duct Type
  • High-Wall Type
  • Flexible Type
  • R410A Refrigerant
  • Turbo Fan
  • Energy Consumption Effect Ratio
  • Compressor Thermo
  • Pulse Motor Valve
  • Wired Remote Controller

Frequently Answers and Questions

What are the different types of indoor units available?
The indoor units are available in 4-Way Air Discharge Cassette Type, Concealed Duct Type, High-Wall Type, and Flexible Type.
What is the standard capacity of the units?
The standard capacity of the units varies depending on the model. Refer to the specifications section for detailed information.
What is the sound level of the outdoor unit?
The sound level of the outdoor unit is measured in an anechoic chamber and is typically between 45 and 50 dB(A).