CONSTRUCTION VIEWS (EXTERNAL VIEWS). Toshiba RAV-SM560 BT-E, RAV-SM560 XT-E, RAV-SM560 KRT-E, RAV-SM800 AT-E, RAV-SM800 KRT-E, RAV-SM800 BT-E, RAV-SM800 XT-E, RAV-SM560 UT-E, RAV-SM560 AT-E, RAV-SM800 UT-E

CONSTRUCTION VIEWS (EXTERNAL VIEWS). Toshiba RAV-SM560 BT-E, RAV-SM560 XT-E, RAV-SM560 KRT-E, RAV-SM800 AT-E, RAV-SM800 KRT-E, RAV-SM800 BT-E, RAV-SM800 XT-E, RAV-SM560 UT-E, RAV-SM560 AT-E, RAV-SM800 UT-E

Add to My manuals
181 Pages

Below you will find brief information for RAV-SM560 AT-E, RAV-SM800 AT-E, RAV-SM560 UT-E, RAV-SM800 UT-E, RAV-SM560 BT-E, RAV-SM800 BT-E, RAV-SM560 KRT-E, RAV-SM800 KRT-E, RAV-SM560 XT-E, RAV-SM800 XT-E. These split-system air conditioners are designed to provide comfortable indoor temperatures in residential and commercial settings. The units are available in a range of capacities to suit different needs and come with various features for optimal performance and energy efficiency.

advertisement

CONSTRUCTION VIEWS (EXTERNAL VIEWS). Toshiba RAV-SM560 BT-E, RAV-SM560 XT-E, RAV-SM560 KRT-E, RAV-SM800 AT-E, RAV-SM800 KRT-E, RAV-SM800 BT-E, RAV-SM800 XT-E, RAV-SM560 UT-E, RAV-SM560 AT-E, RAV-SM800 UT-E | Manualzz

Toshiban lämmitys- ja jäähdytyslaitteiden jälleenmyyjä pääkaupunkiseudulla on Jäähdytinpalvelu RefGroup Oy

3. CONSTRUCTION VIEWS (EXTERNAL VIEWS)

3-1. Indoor Unit

4-Way Air Discharge Cassette Type

RAV-SM560UT-E/RAV-SM800UT-E

200

860 to 910 Recommended external size

Check port

( 450)

Check port

( 450)

Cable draw-in port

30

Surface under ceiling

130

Refrigerant pipe connecting port A

Refrigerant pipe connecting port B

70

270

250

950 Panel external dimension

790 Hanging bolt pitch

346.5

Electric parts box

Surface under ceiling

Standing

850 or less

Standing

640 or less

Surface under ceiling

Indoor unit

Drain up standing size

Hanging bolt M10 or W3/8

Procured locally

256

88

150

Knockout for humidifier

105

A

SM560

Ø6.4

SM800

Ø9.5

B

Ø12.7

Ø15.9

254.5

840 Hanging bolt

480

227

Surface under ceiling

– 13 – www.ilmalämpöpumput.com

35

Ceiling panel

(Sold separately)

57

57.5 25

64

120 97

35

Surface under ceiling

188

Z view

Surface under ceiling

Toshiban lämmitys- ja jäähdytyslaitteiden jälleenmyyjä pääkaupunkiseudulla on Jäähdytinpalvelu RefGroup Oy

Concealed Duct Type

RAV-SM560BT-E

2-Ø200

Discharge port flange

4-M10

Hanging bolt

(Procured locally)

750 ± 7.5 Hanging bolt pitch

700 Dimension of main unit

20

280 252

170

120

70

Drain up kit

(Sold separately)

60

80

For hanging bolt M10

(4-12 x 25 long hole)

Drain pipe connecting port at drain up kit side

(For polyvinyl chloride pipe

(Inner dia. 32, Nominal dia. 25))

25

75

Refrigerant pipe connecting port

(Gas side Ø12.7)

25

730

780 Ceiling opening size

800 Dimension of main unit

565 Hanging bolt pitch

210

240

720

314.5

211

509

45

630

300

130 80

Ø125 knockout hole (Only rear side)

(For air suction)

6-Ø4 tapping screw lower hole Ø160

Refrigerant pipe connecting port

(Liquid side Ø6.4)

80

170

Drain pipe connecting port at main unit side

(For polyvinyl chloride pipe

(Inner dia. 32, Nominal dia. 25))

Panel

2-Ø26 power supply remote controller cord draw-out port

450

470 Ceiling opening size

Suction port canvas

Suction panel

Plane view of main unit

Check port A

450

NOTE 1 :

For maintenance of the equipment, be sure to install a check port A at the position as shown below.

NOTE 2 :

Using the drain up kit sold separately, drain-up by 300 (mm) from drain pipe draw-out port of the main unit is necessary.

The drain-up over 300mm or more is impossible.

(Pipe side)

Discharge side

– 14 – www.ilmalämpöpumput.com

Toshiban lämmitys- ja jäähdytyslaitteiden jälleenmyyjä pääkaupunkiseudulla on Jäähdytinpalvelu RefGroup Oy

RAV-SM800BT-E

2-Ø200

Discharge port flange

4-M10

Hanging bolt

(Procured locally)

1050 ± 7.5 Hanging bolt pitch

1000 Dimension of main unit

290 290 252

20

170

120

70

Drain up kit

(Sold separately)

60

80

For hanging bolt M10

(4-12 x 25 long hole)

Drain pipe connecting port at drain up kit side

(For polyvinyl chloride pipe

(Inner dia. 32, Nominal dia. 25))

25

75

Refrigerant pipe connecting port

(Gas side Ø12.7)

25

1030

1050 Ceiling opening size

800 Dimension of main unit

565 Hanging bolt pitch 210

240

720

314.5

211

509

45

630

300

130 80

Ø125 knockout hole (Only rear side)

(For air suction)

6-Ø4 tapping screw lower hole Ø160

Refrigerant pipe connecting port

(Liquid side Ø6.4)

80

170

Drain pipe connecting port at main unit side

(For polyvinyl chloride pipe

(Inner dia. 32, Nominal dia. 25))

Panel

2-Ø26 power supply remote controller cord draw-out port

450

470 Ceiling opening size

Suction port canvas

Suction panel

Plane view of main unit

Check port A

450

NOTE 1 :

For maintenance of the equipment, be sure to install a check port A at the position as shown below.

NOTE 2 :

Using the drain up kit sold separately, drain-up by 300 (mm) from drain pipe draw-out port of the main unit is necessary.

The drain-up over 300mm or more is impossible.

(Pipe side)

Discharge side

– 15 – www.ilmalämpöpumput.com

Toshiban lämmitys- ja jäähdytyslaitteiden jälleenmyyjä pääkaupunkiseudulla on Jäähdytinpalvelu RefGroup Oy

High-Wall Type

RAV-SM560KRT-E/RAV-SM800KRT-E

998

51

Pipe port from left

(Knockout hole)

Discharge port

Z views

Suction port

50

Pipe port from right

(Knockout hole)

Pipe port from lower side

(Knockout hole)

75 56

110

20

390

490

540

998

763.5

450

Drain hose

Refrigerant pipe connecting port B

Refrigerant pipe connecting port A

20

115 100

Position of installation plate

100 115

SM560

A

Liquid Side

B

Gas Side

Ø6.4

Ø12.7

SM800

Ø9.5

Ø15.9

– 16 – www.ilmalämpöpumput.com

53 or more 53 or more

Space required for service

Z

Toshiban lämmitys- ja jäähdytyslaitteiden jälleenmyyjä pääkaupunkiseudulla on Jäähdytinpalvelu RefGroup Oy

Under Ceiling/Console Type

RAV-SM560XT-E/RAV-SM800XT-E

Front panel

1093

208

For stud bolt

(Ø8 – Ø10)

For stud bolt (Ø6)

200 Min

20

1093

1015

742

450

20

Knock out system

Grille air inlet

Back body

Installation plate

Mount plate

M10 Suspention bolt

Ø74

UNDER CEILING & CONSOLE INSTALLATION

57 18

Wireless remote control

Knock out system

– 17 – www.ilmalämpöpumput.com

Toshiban lämmitys- ja jäähdytyslaitteiden jälleenmyyjä pääkaupunkiseudulla on Jäähdytinpalvelu RefGroup Oy

3-2. Outdoor Unit

RAV-SM560AT-E

A legs

Drain hole (Ø25)

83

Drain hole (2-Ø20 x 88 long hole)

600 97

115.3 125

30

(Long hole pitch F

49.5

147

B legs

Discharge guard

780

115.3

Discharge guide mounting hole

(4-Ø4 embossing)

216

Valve cover

31

23

Earth terminal

25 220

500 (Fan center dividing)

Protective net mounting hole

(2-Ø4 embossing)

43

Protective net mounting hole

(4-Ø4 embossing)

707 30

Charge port

31 134

Refrigerant pipe connecting port

(Ø12.7 flare at gas side)

Refrigerant pipe connecting port

(Ø6.4 flare at liquid side)

Space required for service

R15

52

36

600

2-Ø6 hole

Product external line

Ø11 x 14 U-shape hole

Details of A legs

Ø11 x 14 Ushape holes 2-Ø6 hole

308 302

Product external line

36

52

R15

600

Details of B legs

2-Ø11 x 14 U-shape holes

(For Ø8–Ø10 anchor bolt)

600

Suction port

150 or more 300 or more

150 or more

Discharge port

(Minimum distance up to wall)

500 or more

Discharge port

2-Ø11 x 14 long hole

(For Ø8–Ø10 anchor bolt)

– 18 – www.ilmalämpöpumput.com

Toshiban lämmitys- ja jäähdytyslaitteiden jälleenmyyjä pääkaupunkiseudulla on Jäähdytinpalvelu RefGroup Oy

RAV-SM800AT-E

Knockout

(For draining)

29 90

Drain hole (Ø20 x 88 burring hole)

Drain hole (Ø25 burring hole)

191

Suction port

20

Part B

(Long hole pitch for anchor bolt)

Suction port

Knockout

(For draining)

26 60

150

314

Discharge port

300

900

Part A

95

43

39 47

Handles

(Both sides)

Refrigerant pipe connecting port

(Ø9.5 flare at liquid side)

Refrigerant pipe connecting port

(Ø15.9 flare at gas side)

2

Installation bolt hole

(Ø12 x 17 U-shape holes)

Details of B part

Details of A part

Installation bolt hole

(Ø12 x 17 U-shape holes)

Discharge guide mounting hole

(4-Ø4 embossing)

28 320

300

1

27 58

161

400

2

Z

307

60

96

27

1

Knockout for lower piping

86 7

Z views

2

46

1

30 45

Space required for service

2-Ø12 x 17 U-shape holes

(For Ø8–Ø10 anchor bolt)

600

Suction port

150 or more

150 or more

Discharge port

(Minimum distance up to wall)

500 or more

Discharge port

2-Ø12 x 17 long hole

(For Ø8–Ø10 anchor bolt)

– 19 – www.ilmalämpöpumput.com

advertisement

Key Features

  • 4-Way Air Discharge Cassette Type
  • Concealed Duct Type
  • High-Wall Type
  • Flexible Type
  • R410A Refrigerant
  • Turbo Fan
  • Energy Consumption Effect Ratio
  • Compressor Thermo
  • Pulse Motor Valve
  • Wired Remote Controller

Frequently Answers and Questions

What are the different types of indoor units available?
The indoor units are available in 4-Way Air Discharge Cassette Type, Concealed Duct Type, High-Wall Type, and Flexible Type.
What is the standard capacity of the units?
The standard capacity of the units varies depending on the model. Refer to the specifications section for detailed information.
What is the sound level of the outdoor unit?
The sound level of the outdoor unit is measured in an anechoic chamber and is typically between 45 and 50 dB(A).

Related manuals