Chapter 1 Introduction

1.6 Chassis Specifications

Environment

Temperature -10 - 50

°C Ambient (14-122°F)

Humidity 5-95% non condensing

Alarm relay contact ratings

125VAC 1A

110VDC 0.6A

30VDC 4A

Power Module Specifications

AC Power Module

Input : Universal, 100 ~ 240 ±10% VAC; Frequency : 50/60 Hz ±10%

Output : DC 12V, 200W maximum rating

Connector : C14 (IEC 60320-1)

DC Power Module (two types, DC48 and DC24

Input : 36 ~ 60 VDC (DC48), 18 ~ 36 VDC (DC24)

Output : DC 12V, 160W (DC48), 128W (DC24) maximum rating

Connector : 3 connector terminal block

AC Power Cord Specification (detachable cord, C13 connector, with national plug per national standards)

6A rated 18AWG (conductors with a minimum cross-section area of 0.75 mm

2

)

DC Power Cord Specification (wiring must comply with EN 60950-1:2006 standard)

Conductors with a minimum cross-section area of 1mm

2

(16AWG)

Protective Earth (PE) Specification (wiring must comply with EN 60950-1:2006 standard)

Conductor with a minimum cross-section area of 0.75mm

2

(18AWG), star washer and non-self-tapping M3.5 screw

Power Consumption

~60 watts (fully loaded chassis, with random mix of line card types)

Heat Generation

~120 BTU (fully loaded chassis, with random mix of line card types)

Compliance

European Union : EN55022:2006, Class A, EN55024:1998+A1:2001+A2:2003, and EN60950-1:2001

FCC : part 15, subpart B, class A

Reliability

MTTB : >65,000 hours (25

°C)

Physical Specifications

Dimensions : 438mm (Width) x 302mm (Depth) x 44mm (Height)

(US: 17 1/4" wide x 11 7/8" deep x 1 3/4" high)

Weight : 2.6Kg (US: ~5.75 lbs)

AC module weight : 1050g (US 2.3 lbs)

DC module weight : 930g (US 2 lbs)

NMC card weight : 120g (US 0.25 lbs)

Net Weight : 4.6kgs (US 10 lbs)

(with 1 NMC, 1 AC +1 DC power module & two bracket panels for 19" rack-mounting)

Fully Populated Reference Net Weight: 5.5Kg (US 12 lbs.)

(fully loaded, two powers, NMC and 7 pcs 10/100i line cards)

1.7 NMC (SNMP)

The FRM220-CH08 must be ordered with an NMC Card. The card is placed in the far left, upper card slot.

Management is accomplished either via local control on the asynchronous RS-232 port with an ASCII terminal or via Ethernet and any standard SNMP network management software that supports MIB-II. The WEB GUI based interface provides an easy method for the user to operate and monitor the whole system. Almost all line cards support remote in-band configuration when paired with the same type stand-alone in-band converter.

9

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement

Table of contents