advertisement
Chapter 1 Introduction
1.6 Chassis Specifications
Environment
Temperature -10 - 50
°C Ambient (14-122°F)
Humidity 5-95% non condensing
Alarm relay contact ratings
125VAC 1A
110VDC 0.6A
30VDC 4A
Power Module Specifications
AC Power Module
Input : Universal, 100 ~ 240 ±10% VAC; Frequency : 50/60 Hz ±10%
Output : DC 12V, 200W maximum rating
Connector : C14 (IEC 60320-1)
DC Power Module (two types, DC48 and DC24
Input : 36 ~ 60 VDC (DC48), 18 ~ 36 VDC (DC24)
Output : DC 12V, 160W (DC48), 128W (DC24) maximum rating
Connector : 3 connector terminal block
AC Power Cord Specification (detachable cord, C13 connector, with national plug per national standards)
6A rated 18AWG (conductors with a minimum cross-section area of 0.75 mm
2
)
DC Power Cord Specification (wiring must comply with EN 60950-1:2006 standard)
Conductors with a minimum cross-section area of 1mm
2
(16AWG)
Protective Earth (PE) Specification (wiring must comply with EN 60950-1:2006 standard)
Conductor with a minimum cross-section area of 0.75mm
2
(18AWG), star washer and non-self-tapping M3.5 screw
Power Consumption
~60 watts (fully loaded chassis, with random mix of line card types)
Heat Generation
~120 BTU (fully loaded chassis, with random mix of line card types)
Compliance
European Union : EN55022:2006, Class A, EN55024:1998+A1:2001+A2:2003, and EN60950-1:2001
FCC : part 15, subpart B, class A
Reliability
MTTB : >65,000 hours (25
°C)
Physical Specifications
Dimensions : 438mm (Width) x 302mm (Depth) x 44mm (Height)
(US: 17 1/4" wide x 11 7/8" deep x 1 3/4" high)
Weight : 2.6Kg (US: ~5.75 lbs)
AC module weight : 1050g (US 2.3 lbs)
DC module weight : 930g (US 2 lbs)
NMC card weight : 120g (US 0.25 lbs)
Net Weight : 4.6kgs (US 10 lbs)
(with 1 NMC, 1 AC +1 DC power module & two bracket panels for 19" rack-mounting)
Fully Populated Reference Net Weight: 5.5Kg (US 12 lbs.)
(fully loaded, two powers, NMC and 7 pcs 10/100i line cards)
1.7 NMC (SNMP)
The FRM220-CH08 must be ordered with an NMC Card. The card is placed in the far left, upper card slot.
Management is accomplished either via local control on the asynchronous RS-232 port with an ASCII terminal or via Ethernet and any standard SNMP network management software that supports MIB-II. The WEB GUI based interface provides an easy method for the user to operate and monitor the whole system. Almost all line cards support remote in-band configuration when paired with the same type stand-alone in-band converter.
9
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 7 Chapter 1 Introduction
- 7 1.0 Introduction
- 7 1.1 Functional Description
- 7 1.2 Chassis Front Description
- 8 1.3 LED Indicators and Alarm Relay
- 8 1.4 Chassis Rear Description
- 8 1.5 Chassis Physical Dimensions
- 9 1.6 Chassis Specifications
- 9 1.7 NMC (SNMP)
- 10 1.8 Line card options
- 10 1.8.1 FRM220-10/100i In-band managed 10/100 Fiber Media Converter
- 11 1.8.2 FRM220-10/100iS-2 Dual Channel In-band managed 10/100 Fiber Media Converter
- 12 1.8.3 FRM220-10/100i-2E In-band managed 10/100 Fiber Media Converter
- 13 1.8.4 FRM220-10/100A(S) 802.3ah In-band managed 10/100 Fiber Media Converter
- 14 1.8.5 FRM220-1000EA(S) 802.3ah In-band managed Gigabit Fiber Media Converter
- 15 1.8.6 FRM220-1000EDS Managed Gigabit Fiber Media Converter
- 16 1.8.7 FRM220-E1/T1 In-band managed G.703 E1/T1(DS1) Fiber Modem
- 17 1.8.8 FRM220-Data In-band managed V.35, X.21, RS-530/449/232 Fiber Modem
- 18 1.8.9 FRM220-Serial/485 In-band managed RS-485/422/232 Fiber Modem
- 19 1.8.10 FRM220-FXO/FXS In-band managed POTS (Voice) over Fiber Modem
- 20 1.8.11 FRM220-155MS SM/MM, MM/SM converter / repeater
- 21 1.8.12 FRM220-2.7G-2S, 2.7Gbps 3R Fiber Transponder
- 22 1.8.13 FRM220-2.7G-3S 3R Transponder with Protection
- 23 1.8.14 FRM220-10G-xx 10Gbps 3R Fiber Transponder
- 24 1.8.15 FRM220-MD40/80 CWDM Mux/DeMux
- 25 1.8.16 FRM220-iMUX Inverse Multiplexer Blades
- 26 1.8.17 FRM220-Eoe1 Ethernet over E1 Converter
- 27 1.8.18 FRM220-E1/Data DSU/CSU Converter Card
- 28 1.8.19 FRM220-FTEC E1/T1 Cross Rate Converter Card
- 29 1.8.20 FRM220-1000TS GbE to Gigabit Fiber Converter Card
- 30 1.8.21 FRM220-4G 2R 4.25G Transponder Card
- 31 1.8.22 FRM220-Serial/FDC RS-485/RS-232 Fiber Ring Converter Card
- 32 1.8.23 FRM220-FOM04 4xE1/T1 +100M Ethernet Fiber Optical Multiplexer Card
- 33 Chapter 2 Installation
- 33 2.1 Introduction
- 33 2.2 Site Preparation
- 33 2.3 Mechanical Assembly
- 33 2.3.1 Rack mounting
- 34 2.3.2 Power/Fan Modules Removal/Replacement
- 34 2.3.3 Line Card Conversion, Stand-alone/Rack
- 35 2.4 Electrical Installation
- 35 2.5 Alarm Installation
- 36 2.6 NMC Card Installation
- 36 2.7 Line Card Installation
- 37 Chapter 3. Management Quick Start
- 37 3.1 Introduction
- 37 3.2 Management Methods
- 37 3.3 Console Terminal
- 37 3.3.1 Terminal Connection & Settings
- 37 3.3.2 Terminal Login
- 38 3.3.3 TCP/IP Setup
- 38 3.3.4 Test TCP/IP Connection
- 39 3.4 Telnet Terminal
- 39 3.5 Web Based Manager
- 40 3.6 Element Management System (EMS)