SAFETY TEST REPORT

Add to my manuals
51 Pages

advertisement

SAFETY TEST REPORT | Manualzz

EN 60065

7

7.1

Clause

6

6.1

6.2

7.1.1

7.1.2

7.1.3

7.1.4

7.1.5

7.2

8

6.1

EN 60065

8.1

8.2

8.3

8.4

8.5

Requirement – Test Result - Remark Verdict

HAZARDOUS RADIATION

Ionizing radiation < 36 pA/kg (0,5 mR/h)

N

There is no CRT. No Ionizing

Radiation generated.

N

N European Council Directive 96/29/Euratom of 13

May 1996 10cm from outer surface of apparatus

<1µSv/h (0,1mR/h)

Laser radiation, emission limits to IEC 60825-1 ....: LEDs for indication considered inherently Class 1

P

Emission limits under fault conditions ....................: Class 1

HEATING UNDER NORMAL OPERATING CONDITIONS

Temperature rises not exceeding specified values, no operation of fuse links

Temperature rise of accessible parts

(see appended table 7.1)

(see appended table 7.1)

P

P

P

P

P Temperature rise of parts providing electrical insulation

(see appended table 7.1)

Temperature rise of parts acting as a support or as a mechanical barrier

(see appended table 7.1) P

Temperature rise of windings

Parts not subject to a limit under 7.1.1 to 7.1.4

(see appended table 7.1)

(see appended table 7.1)

P

P

P Softening temperature of insulating material supporting parts conductively connected to the mains carrying a current > 0,2 A at least 150

o

C

CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION

AGAINST ELECTRIC SHOCK

Conductive parts covered by lacquer, paper, untreated textile oxide films and beads etc. considered to be bare

P

Considered P

No shock hazard when changing voltage setting device, fuse-links or handling drawers etc.

No changing voltage setting device etc.

No such hygroscopic material.

N

N Insulation of hazardous live parts not provided by hygroscopic material

No risk of electric shock following the removal of a cover which can be removed by hand

No risk of electric shock P

Class I equipment

Basic insulation between hazardous live parts and earthed accessible parts

Resistors bridging basic insulation complying with

14.2.1 a)

Basic insulation complies with requirements specified in clause 10 and 13.

No resistors bridging basic insulation.

P

P

N

Safety Test Report #: SHE-1007-10462-LVD

Prepared for Shenzhen KTC Technology Co., Ltd.

Prepared by EMC Compliance Management Group. Page 6 of 48

8.9

Clause

8.6

8.7

8.8

8.10

EN 60065

Requirement – Test Result - Remark Verdict

Class II equipment and Class II constructions within Class I equipment

Reinforced or double insulation between hazardous live parts and accessible parts

Components bridging reinforced or double insulation complying with 14.1 a) or 14.3

Basic and supplementary insulation each being bridged by a capacitor complying with 14.2.1 a)

See below.

Double/Reinforced insulation complies with requirements specified in clause 10 and 13.

1) The apparatus have isolating transformers (T01) complies with clause 14.3.

2) Optocoupler (IC2) complies with 14.11.

Certified capacitors CY1, CY2 are approved components, see appended table 14.

P

P

P

P

Reinforced or double insulation being bridged with

2 capacitors in series complying with 14.2.1 a)

N

Reinforced or double insulation being bridged with a single capacitor complying with 14.2.1 b)

Certified capacitors CY3 is approved components, see appended table 14.

P

Basic insulation bridged by components complying with 14.3.4.3

None N

This clause is voided.

Basic or supplementary insulation > 0,4 mm (mm) : The thickness of supplementary insulation used in wire >0.4mm

Reinforced insulation > 0,4 mm (mm) ....................: a. Transformer bobbin: min.

0.4mm thickness. b. Optocouplers inner insulation, ref. 14.11.

Thin sheet insulation

Basic or supplementary insulation, at least two layers, each meeting 10.3

N

P

P

P

P

Basic or supplementary insulation, three layers any two of which meet 10.3

N

Reinforced insulation, two layers each of which meet 10.3

N

P Reinforced insulation, three layers any two which meet 10.3

Adequate insulation between internal hazardous live conductors and accessible parts

Double insulated. P

Adequate insulation between internal hazardous live parts and conductors connected to accessible parts

Double insulation between conductors connected to the mains and accessible parts

All internal live parts are separated by reinforced or double insulation between accessible parts.

Class I apparatus

P

N

Safety Test Report #: SHE-1007-10462-LVD

Prepared for Shenzhen KTC Technology Co., Ltd.

Prepared by EMC Compliance Management Group. Page 7 of 48