EN 60065

Clause

8.11

8.12

8.13

8.14

8.15

8.16

8.17

8.18

8.19

8.19.1

8.19.2

8.20

8.21

9

9.1

9.1.1

9.1.1.1

9.1.1.2

9.1.2

Requirement – Test Result - Remark Verdict

Detaching of wires

No undue reduction of creepages or clearance distances if wires become detached

Vibration test carried out .........................................: No wire detached after test.

Adequate cross-sectional area of internal wiring to mains socket-outlets

Internal wires fixed by cable ties and connectors.

P

P

P

P

No windows, lenses, etc N Adequate fastening of windows, lenses, lamp covers etc. (pull test 20 N for 10 s)

Adequate fastening of covers (pull test 50 N for

10 s)

No risk of damage to the insulation of internal wiring due to hot parts or sharp edges

Only special supply equipment can be used

Insulated winding wire without additional interleaved insulation

Endurance test as required by 8.17

Disconnection from the mains

Disconnect device

All-pole switch or circuit breaker with >3mm contact separation

Mains switch ON indication

See appended table 8.14.

No hot parts and sharp edges can be touched.

Not such equipment.

Not applicable.

Not applicable.

All-pole switch used.

VDE approved.

P

P

N

N

N

P

P

P

P

Switch not fitted in the mains cord

Bridging components comply with clause 14

Symbol used complies with clause 5.

No such components bridging switch

Not applicable.

N

N

N material(+A1)

P

ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS

Testing on the outside

For voltages >1000 V ac or >1500 V dc complies with clause 13.3.1 for basic insulation

Not applicable

P

N

Touch current measured from terminal devices using the network in annex D .................................:

Refer to appended table 9.1.1

Discharge not exceeding 45 μC

Energy of discharge not exceeding 350 mJ

Test with test finger and test probe

No hazardous live shafts of knobs, handles or levers

No accesses of hazardous live with the test finger and test probe.

No such components

P

P

N

P

N

Safety Test Report #: SHE-1007-10462-LVD

Prepared for Shenzhen KTC Technology Co., Ltd.

Prepared by EMC Compliance Management Group. Page 8 of 48