SAFETY TEST REPORT

Add to my manuals
51 Pages

advertisement

SAFETY TEST REPORT | Manualzz

9.1.7

9.2

10

10.1

10.2

10.3

11

11.1

11.2

11.2.1

11.2.2

11.2.3

Clause

9.1.3

9.1.4

9.1.5

9.1.6

EN 60065

Requirement – Test Result - Remark Verdict

Ventilation holes tested by means of

4 mm x 100 mm test pin

Terminal devices tested with 1 mm x 20 mm test pin (10 N); test probe D of IEC 61032

No hazard.

No hazard.

Terminal devices tested with 1 mm x 100 mm straight wire (1 N); test probe D of IEC 61032

No hazard.

Pre-set controls tested with 2 mm x 100 mm test pin (10 N); test probe C of IEC 61032

No such pre-set controls.

No shock hazard due to stored charge on withdrawal of the mains plug; voltage (V) after 2 s :

After conducted at least 10 times, the measured voltage after 2s is 0V.

If C is not greater than 0,1 μF no test needed

Enclosure sufficiently resistant to external force

Test probe 11 of IEC 61032 for 10 s (50 N) No damage.

Test hook of fig. 4 for 10 s (20 N) No damage.

30 mm diameter test tool for 5 s (100 or 250 N) ....: 100N applied, no damage.

No hazard after removing a cover by hand Cover can’t be removed by hand

INSULATION REQUIREMENTS

Insulation resistance (MΩ) at least 2 MΩ min. after surge test for basic and 4 MΩ min. for reinforced insulation .................................................................:

Class I apparatus.

Humidity treatment 48 h or 120 h ...........................: 30°C, 93% rh chamber for 48 hours

Insulation resistance and dielectric strength See appended table 10.3

FAULT CONDITIONS

No shock hazard under fault condition

Heating under fault condition

See appended table 11.1

See appended table

11.2(con’t)

No hazard from softening solder

Measurement of temperature rises

Temperature rise of accessible parts

Temperature rise of parts, other than windings, providing electrical insulation

Temperature rise of printed circuit boards (PCB) exceeding the limits of table 3 by max. 100 K for max. 5 min

The temperature rise of PCB board does not exceed the limit of table 3.

P

P

P

N

P

P

No such condition P see appended table 11.2(con’t) P see appended table 11.2(con’t) P see appended table 11.2(con’t) P

N

P

N

P

P

P

P

P

P

N

N

P

P

Safety Test Report #: SHE-1007-10462-LVD

Prepared for Shenzhen KTC Technology Co., Ltd.

Prepared by EMC Compliance Management Group. Page 9 of 48