SAFETY TEST REPORT

Add to my manuals
51 Pages

advertisement

SAFETY TEST REPORT | Manualzz

EN 60065

Clause

11.2.4

11.2.6

12

12.1.1

12.1.2

12.1.3

12.1.4

12.1.5

12.2

12.3

12.4

12.5

12.6

12.6.1

13

13.1

Requirement – Test Result - Remark Verdict a) Temperature rise of printed circuit boards (PCB) to 20.1.3, exceeding the limits of table 3 by not more than 100 K for an area not greater than 2 cm²

N b) Temperature rise of printed circuit boards (PCB) to 20.1.3 up to 300 K for an area not greater than

2 cm² for a maximum of 5 min

N

Meets all the special conditions if conductors on printed circuit boards are interrupted

No conductors are interrupted / peeled / loosened during fault conditions.

P

Class I protective earthing maintained

Temperature rise of parts acting as a support or mechanical barrier

Temperature rise of parts not subject to the limits of 11.2.1 to 11.2.5

Temperature rises are within the limits

See appended table

11.2(con’t)

See appended table

11.2(con’t)

P

P

P

P

P

N

MECHANICAL STRENGTH

Bump test where mass >7 kg

Vibration test

Impact hammer test

<7kg

Yes, no hazard.

Steel ball test See appended table 12.1.3

Drop test for portable apparatus where mass < 7kg No hazard.

Thermoplastic enclosures strain relief test

After the test, the apparatus can withstand the dielectric strength test as specified in

10.3 and show no damage.

Fixing of knobs, push buttons, keys and levers

70°C, See appended table

12.1.5

Push buttons are fastened that their use did not impair the protection against electric shock.

P

P

P

P

P

P

Remote controls with hazardous live parts

Drawers (pull test 50 N, 10 s)

Antenna coaxial sockets providing isolation

Telescoping or rod antennas construction

Telescoping or rod antennas securement

CLEARANCE AND CREEPAGE DISTANCES

Clearances in accordance with 13.3

Creepage distances in accordance with 13.4

No drawers.

No antenna coaxial sockets direct connect primary circuit.

No such construction

No such construction

See clause 13.3

See clause 13.4

Safety Test Report #: SHE-1007-10462-LVD

Prepared for Shenzhen KTC Technology Co., Ltd.

Prepared by EMC Compliance Management Group. Page 10 of 48

N

N

N

N

N

P

P

P

advertisement