SAFETY TEST REPORT

Add to my manuals
51 Pages

advertisement

SAFETY TEST REPORT | Manualzz

EN 60065

Clause

13.2

13.3

13.3.2

13.3.3

13.3.4

13.4

13.5

13.5.1

Requirement – Test

Determination of operating voltage

Clearances

Circuits conductively connected to the mains comply with table 8 and, where applicable, table 9

Circuits not conductively connected to the mains comply with table 10

Measurement of transient voltages

Result - Remark

See appended table 13.2

No such construction provided

Creepage distances

Creepage distances greater than table 11 minima

See appended table 13.2

Printed boards No such PCB used

Verdict

P

See appended table 13.3 P

P

N

N

P

P

N

13.5.2

13.6

Clearances and creepage distances between conductors on printed circuit boards, one of which may be conductively connected to the mains, as in fig. 10

N

Type B coated printed circuit boards complying with IEC 60664-3 (basic insulation only)

N

No such construction N Conductive parts along uncemented joints clearances and creepage distances comply with

13.3 and 13.4

Conductive parts along reliably cemented joints comply with 8.8

No such construction N

N 13.7

13.8

Enclosed, enveloped or hermetically sealed parts: not conductively connected to the mains: clearances and creepage distances as in table 12

Parts filled with insulating compound, meeting the requirements of 8.8

No such construction

Opto-couplers meet the requirements

14

COMPONENTS

14.1 Resistors a) Resistors between hazardous live parts and accessible metal parts b) Resistors, other than between hazardous live parts and accessible parts

14.2

No such resistors.

Three bleeder resistors (RXA,

RXB, RXC, RXD) connected between Live and Neutral in series, located after fuse.

Shorting-circuit or disconnecting of resistor does not cause infringement of the requirement for operation under fault conditions. c) Resistors separately approved ...........................: No such component

Capacitors and RC units See below

Capacitors separately approved See below

P

P

P

N

N

N

P

P

Safety Test Report #: SHE-1007-10462-LVD

Prepared for Shenzhen KTC Technology Co., Ltd.

Prepared by EMC Compliance Management Group. Page 11 of 48

EN 60065

Clause

14.2.1

Requirement – Test Result - Remark Verdict

14.2.2

14.2.3

14.2.5

Y capacitors tested to IEC 60384-14, 2 nd

edition ...: Y1 or Y2 capacitors(CY1,CY2,

CY3) certified according to IEC

60384-14: 2nd edition.

X capacitors tested to IEC 60384-14, 2 nd

edition ...: X2 capacitors (CX2) certified according to IEC 60384-14:

2nd edition.

Capacitors operating at mains frequency but not connected to the mains: tests for X2 ......................:

No such capacitor used.

P

P

N

Capacitors with volume exceeding 1750 mm³, where short-circuit current exceeds 0,2 A: compliance with IEC60384-1, 4.38 category B or better .......................................................................:

N

Capacitors with volume exceeding 1750 mm³, mounted closer to a potential ignition source than table 5 permits: compliance with IEC 60 384-1,

4.38 category B or better ........................................:

N

14.3

Shielded by a barrier to V-0 or metal .....................:

Inductors and windings

Comply with IEC 61558-1, IEC 61558-2

(as relevant) and clause 20.1.4

N

P

N

14.3.1 Transformers and inductors marked with manufacturer's name and type ...............................:

P

Transformers and inductors separately approved .:

14.3.2 General

N

P

14.3.3 Constructional requirements

14.3.3.1 Clearances and creepage distances comply with clause 13

14.3.3.2 Transformers meet the constructional requirements

Transformers complied with clause 13.

Checked by inspection.

P

P

P

14.3.4.1 Class II transformers have adequate separation between hazardous live parts and accessible parts

(double or reinforced insulation)

Double or reinforced insulation between hazardous live windings and accessible conductive parts.

Coil formers and partition walls > 0,4 mm

14.3.4.2 Class I transformers, with basic insulation and protective screening only if all 7 conditions of

14.3.4.2 are met

14.3.4.3 Separating transformers with at least basic insulation

The bobbin: > 0.4mm thickness.

Transformer is evaluated with

Class II construction.

P

N

N

N

14.3.5.1 Class II transformers have adequate insulation between hazardous live parts and accessible parts

(double or reinforced insulation)

Double or reinforced insulation between hazardous live windings and accessible conductive parts.

P

Safety Test Report #: SHE-1007-10462-LVD

Prepared for Shenzhen KTC Technology Co., Ltd.

Prepared by EMC Compliance Management Group. Page 12 of 48

EN 60065

Clause Requirement – Test Result - Remark Verdict

14.4.1

14.4.2

Coil formers and partition walls > 0,4 mm

14.3.5.2 Class I transformers have adequate insulation between hazardous live parts and accessible conductive parts or those conductive parts or protective screens connected to a protective earth terminal

Winding wires connected to protective earth have adequate current-carrying capacity

14.4 High voltage components

High-voltage components and assemblies:

U > 4 kV (peak) separately approved

Component meets category V-1 of IEC 60707

High voltage transformers and multipliers tested as part of the submission

The bobbin: > 0.4mm thickness.

Windings of Class II construction used.

P

N

N

N

N

N

Not applicable N

High voltage assemblies and other parts tested as part of the submission

N

Protective devices used within their ratings Mains fuse, F01

External clearances and creepage distances meet requirement of clause 13 for the voltage across the device when opened

Certified protective devices applied. See List of Critical components.

P

P

P

14.5.1.1 a) Thermal cut-outs separately approved

14.5.1.2 b) Thermal cut-outs tested as part of the submission a) Thermal links separately approved b) Thermal links tested as part of the submission

N

N

N

N

14.5.1.3 Thermal devices re-settable by soldering

14.5.2.1 Fuse-links in the mains circuit according to IEC

60127

No thermal devices

Fuse is approved according to

IEC 60127. See List of critical components.

N

P

14.5.2.2 Correct marking of fuse-links adjacent to holder ...: Correct marking applied close to the fuse:

F01 T2AL, 250Vac

14.5.2.3 Not possible to connect fuses in parallel ................: No possible to connect fuses in parallel.

P

P

14.5.2.4 Not possible to touch hazardous live parts when replacing fuse-links without the use of a tool .........:

P

14.5.3 PTC-S thermistors comply with IEC 60730-1

PTC-S devices (15 W) category V-1 or better

No such component N

N

N and their position is correctly marked

Safety Test Report #: SHE-1007-10462-LVD

Prepared for Shenzhen KTC Technology Co., Ltd.

Prepared by EMC Compliance Management Group. Page 13 of 48

14.9

14.9.1

14.9.2

14.9.3

14.9.4

14.7

14.8

EN 60065

Clause Requirement – Test

14.6 Switches

14.6.1 a) Separate testing to IEC 61058 including:

10 000 operations normal pollution suitability resistance to heat and fire level 3 and V-0 compliance with annex G, G.1.1

14.6.1 b) Tested in the apparatus:

Switch controlling > 0.2A with open contact voltage > 35 V (peak)/24 V dc complying with

14.6.3, 14.6.4 and V-0 in annex G, G.1.1

Switch controlling > 0.2A with open contact voltage < 35 V (peak)/24 V dc complying with

14.6.3 and V-0 in annex G, G.1.1

14.6.2

14.6.3

14.6.4

14.6.5

Result - Remark Verdict

P

N

N

N

N

Switch controlling < 0.2A with open contact voltage > 35 V (peak)/24 V dc complying with

14.6.4 and V-0 in annex G, G.1.1

N

Switch tested to 14.6.1 b) constructed to IEC

61058-1 subclause 13.1 and has making/breaking action independent of speed of actuation

N

N Switch tested to 14.6.1 b) compliant with IEC

61058-1 subclause 16.2.2 d) and m) not attaining excessive temperatures in use

Switch tested to 14.6.1 b) has adequate dielectric strength

Mains switch controlling mains socket outlets additional tests to IEC 60058-1

N

No such components N

Socket outlet current marking correct

Safety interlocks

Safety interlocks to 2.8 of IEC 60950

Voltage setting devices

Voltage setting device not likely to be changed accidentally

No safety interlock

N

N

No voltage setting devices

N

N

N

14.10

Motors

Endurance test on motors

Motor start test

Dielectric strength test

Not adversely affected by oil or grease etc.

Protection against moving parts

No such components N

N

N

N

N

N

Motors with phase-shifting capacitors, three-phase motors and series motors meet clause. B.8, B.9 and B.10 of IEC 60950, Annex B

N

Batteries No battery used N

Safety Test Report #: SHE-1007-10462-LVD

Prepared for Shenzhen KTC Technology Co., Ltd.

Prepared by EMC Compliance Management Group. Page 14 of 48