SAFETY TEST REPORT

Add to my manuals
51 Pages

advertisement

SAFETY TEST REPORT | Manualzz

Clause

14.10.1

14.10.2

14.10.3

14.10.4

14.10.5

14.11

14.12

15

15.1.1

15.1.2

15.1.3

15.2

EN 60065

Requirement – Test Result - Remark Verdict

Batteries mounted with no risk of accumulation of flammable gases

No possibility of recharging non-rechargeable batteries

Recharging currents and times within manufacturers limits

Lithium batteries discharge and reverse currents within the manufacturers limits

N

N

N

N

Battery mould stress relief

Battery drop test

Optocouplers Opto-coupler (IC2) is approval component, see list of critical components.

N

N

P

P

P

Optocouplers comply with Cl. 8

Internal and external dimensions to 13.1. or alternatively 13.6 (jointed insulation)

Surge suppression varistors

Comply with IEC 61051-2

Not connected between mains and accessible parts except for earthed parts of permanently connected apparatus

Complies with the current pulse, fire hazard and thermal stress requirements of 14.12

No such component used. N

N

N

N

TERMINALS

Mains plug, appliance inlet, interconnection couplers and mains socket-outlet meet the appropriate standard

See appended table 14.2

Connectors for antenna, earth, audio, video or data:

No risk of insertion in mains socket-outlets Signal input and output connectors are so designed that plug inserting into mains socket-outlets is unlikely occur.

No risk of insertion into audio or video: outlets marked with the symbol of 5.2

No risk.

P

P

P

P

P

Output terminals of a.c. adaptors or similar devices not compatible with household mains socketoutlets

N

Provision for protective earthing P

Accessible conductive parts of Class I equipment reliably connected to earth terminal, within equipment

P

Safety Test Report #: SHE-1007-10462-LVD

Prepared for Shenzhen KTC Technology Co., Ltd.

Prepared by EMC Compliance Management Group. Page 15 of 48

15.3

15.3.1

15.3.2

15.3.3

15.3.4

Clause

15.3.5

15.3.6

15.3.7

15.3.8

15.3.9

EN 60065

Requirement – Test Result - Remark Verdict

Class I supply equipment with non-hazardous live output voltage: output circuit not connected to earth

Protective earth conductors correctly coloured

Equipment with non-detachable mains cord provided with separate protective earth terminal near mains input

P

P

Protective earth terminal resistant to corrosion

Earth resistance test: < 0,1

Ω at 25 A ...................: 0.045Ω

P

P

P Terminals for external flexible cords and for permanent connection to the mains supply

Adequate terminals for connection of permanent wiring

Reliable connection of non-detachable cords:

Not soldered to conductors of a printed circuit board

P

P

P

P

Adequate clearances and creepage distances between connections should a wire break away

Wire secured by additional means to the conductor

P

P

Screws and nuts clamping conductors have adequate threads: ISO 261, ISO 262 or similar

P

P Soldered conductors wrapped around terminal prior to soldering or held in place by additional means

Clamping of conductor and insulation if not soldered or held by screws

Terminals allow connection of appropriate crosssectional area of conductors, for the rated current of the equipment

Terminals to 15.3.3 have sizes required by table 16

P

P

P

Terminals clamp conductors between metal and have adequate pressure

P

Terminals designed to avoid conductor slipping out when tightened or loosened

P

P Terminals adequately fixed to avoid loosening when the clamping is tightened or loosened and stress on internal wiring is avoided

Terminals carrying a current more than 0,2 A: contact pressure not transmitted by insulating material except ceramic

Termination of non-detachable cords: wires terminated near to each other

N

P

Safety Test Report #: SHE-1007-10462-LVD

Prepared for Shenzhen KTC Technology Co., Ltd.

Prepared by EMC Compliance Management Group. Page 16 of 48

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals