SAFETY TEST REPORT

Add to my manuals
51 Pages

advertisement

SAFETY TEST REPORT | Manualzz

Clause

15.4

15.4.1

15.4.2

15.4.3

16

16.1

16.2

16.3

16.4

16.5

16.6

16.7

EN 60065

Requirement – Test Result - Remark Verdict

Terminals located and shielded: test with 8 mm strand

Devices forming a part of the mains plug

No undue strain on mains socket-outlets

P

No plug-in equipment N

N

N Device complies with standard for dimensions of mains plugs

Device has adequate mechanical strength (tests a,b,c)

N

EXTERNAL FLEXIBLE CORDS

External flexible cord is tested with end products.

N

Mains cords sheathed type, complying with

IEC 60227 for PVC or IEC 60245 for synthetic rubber cords ............................................................:

N

Non-detachable cords for Class I have green/yellow core for protective earth

Mains cords conductors have adequate crosssectional area for rated current consumption of the equipment

N

N

N a) Flexible cords not complying with 16.1, used for interconnections between separate units of equipment used in combination and carrying hazardous live voltages, have adequate dielectric strength

Not applicable b) Flexible cords not complying with 16.1, withstand bending and mechanical stress (3.2 of

IEC 60227-2)

N

Flexible cords used for connection between equipment have adequate cross-sectional areas to avoid temperature rise under normal and fault conditions

N

Adequate strain relief on external flexible cords N

Not possible to push cord back into equipment N

Strain relief device unlikely to damage flexible cord

For mains cords of Class I equipment, hazardous live conductors become taut before earth conductor

N

N

N Apertures for external flexible cord: no risk of damage to the cord during assembly or movement in use

Detachable cord used

Transportable musical instruments and amplifiers fitted with detachable cord set with appliance inlet to IEC 60320-1

Not transportable musical instrument

N

Safety Test Report #: SHE-1007-10462-LVD

Prepared for Shenzhen KTC Technology Co., Ltd.

Prepared by EMC Compliance Management Group. Page 17 of 48