SAFETY TEST REPORT

Add to my manuals
51 Pages

advertisement

SAFETY TEST REPORT | Manualzz

EN 60065

Clause

20.1.4

20.2.1

20.2.2

20.2.3

A

Requirement – Test Result - Remark Verdict

Components and parts not covered by 20.1.1,

20.1.2 and 20.1.3 (other than fire enclosures) mounted nearer to a potential ignition source than the distances in Table 21 comply with the relevant flammability category in Table 21

The distance between potential ignition source and components, parts not covered by 20.1.1 and 20.1.2, 20.1.3 exceeded the value specified in table 13.

Components and parts as above but shielded from a potential ignition source, with the barrier area in accordance with Table 21 and fig. 13

No barrier

Open circuit voltage is far less than 4 kV

Potential ignition sources with open circuit voltage

> 4 kV (peak) a.c. or d.c. contained in a fire enclosure to V-1

Internal fire enclosures with openings not exceeding 1 mm in width and with openings for wires completely filled

P

N

N

N

N

Requirements of 20.2.1 and 20.2.2 met by an internal fire enclosure

N

APPENDIX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH

PROTECTION AGAINST SPLASHING WATER

N

B

A.5.1 j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not apply

Not provided with protection against splashing water

A.10.2.1 Enclosure provides protection against splashing water

N

N

N

APPENDIX B, APPARATUS TO BE CONNECTED TO THE

TELECOMMUNICATION NETWORKS

Complies with IEC 62151 clause 1 Not connected to telecommunication networks

Complies with IEC 62151 clause 2

N

N

N

N Complies with IEC 62151 clause 3 but with 3.5.4 modified to 2.4.10 of this standard

Complies with IEC 62151 clause 4 but with 4.1.2,

4.1.3 and 4.2.1.2 modified in accordance with annex B of this standard

N

N Complies with IEC 62151 cause 5 but with 5.3.1 modified in accordance with annex B of this standard

Complies with IEC 62151 clause 6

Complies with IEC 62151 clause 7

Complies with IEC 62151 annex A, B and C

N

N

N

Safety Test Report #: SHE-1007-10462-LVD

Prepared for Shenzhen KTC Technology Co., Ltd.

Prepared by EMC Compliance Management Group. Page 20 of 48