SAFETY TEST REPORT

Add to my manuals
51 Pages

advertisement

SAFETY TEST REPORT | Manualzz

Clause

ZB

2.6.1

13.3.1

15.1.1

EN 60065

Requirement – Test Result - Remark Verdict

ANNEX ZB TO EN 60065, SPECIAL NATIONAL CONDITIONS

DK: certain types of Class I apparatus, see 15.1.1, may be provided with a plug not establishing earthing continuity when inserted in Danish socketoutlets

N

N

NO: In Norway, due to IT power distribution system used, the a.c. MAINS supply voltage is considered to be equal to the line-to-line voltage, and will remain 230V in case of a single earth fault.

N

N DK: mains cord for single-phase equipment having a rated current not exceeding 10 A shall be provided with a plug according to Heavy Current

Regulations Section 107-2-D1

DK: Class I equipment with socket-outlets with earthing contact, or which are intended to be used in locations where protection against indirect contact is required shall be provided with a plug in compliance with Standard Sheet DK 2-1a

N

N DK: socket-outlets for providing power to Class II equipment with a rated current of 2,5 A shall have dimensions according to the drawing on page 131 of EN 60 065:98 other dimensions shall be to

IEC 60 083 Standard Sheet C 1a for portable socket-outlets

DK: mains socket-outlets with earthing contact shall comply with Heavy Current Regulations

Section 107-2-D1, Standard Sheet DK 1-3a,

DK 1-5a or DK 1-7a

GB: equipment fitted with a flexible cable or cord provided with a 13A BS 1363 plug as in Statutory

Instrument 1768:94

IE: equipment fitted with a flexible cable or cord provided with a 13 A plug in accordance with

Statutory Instrument 525:97

N

N

N

NO: mains socket-outlets on Class II equipment meet CEE Publication 7 with the following amendments:

- dimensions 2,5 A, 250 V socket-outlets shall comply with Standard Sheet 1 page 132 of

EN 60 065:98

- mechanical strength 2,5 A, 250 V socket-outlets tested as specified in EN 60 065, 12.1.3

---

N

N

- protecting rim also tested N

NO: method b) of 8.1 is not permitted. Double or reinforced insulation is required between parts connected to the mains and parts connected to the public telecommunications network

N

Safety Test Report #: SHE-1007-10462-LVD

Prepared for Shenzhen KTC Technology Co., Ltd.

Prepared by EMC Compliance Management Group. Page 21 of 48