advertisement
Appendix
B
Accessories and Dimensions
For information on…
See page
Product Selection
Table B.A Catalog Number Description
22B A
Drive
1P5 N 1 1 4
Voltage Rating Rating Enclosure HIM Emission Class Comm Slot
Table B.B PowerFlex 40 Drives
Drive Ratings
Input Voltage
120V 50/60 Hz
1-Phase
No Filter
240V 50/60 Hz
1-Phase
With Integral “S Type”
EMC Filter
240V 50/60 Hz
1-Phase
No Filter
240V 50/60 Hz
3-Phase
No Filter
480V 50/60 Hz
3-Phase
No Filter
1.5
2.2
3.7
5.5
1.5
2.2
0.4
0.75
1.5
2.2
0.4
0.75
kW
0.4
0.75
1.1
0.4
0.75
2.2
4.0
5.5
7.5
7.5
0.4
0.75
1.5
2.0
3.0
5.0
7.5
2.0
3.0
0.5
1.0
2.0
3.0
0.5
1.0
HP
0.5
1.0
1.5
0.5
1.0
3.0
5.0
7.5
10.0
10.0
0.5
1.0
2.0
33.0
1.4A
2.3A
4.0A
6.0A
10.5A
12.0A
17.0
8.0A
12.0A
2.3A
5.0A
8.0A
12.0A
17.5A
24.0
Output Current
2.3A
5.0A
6.0A
2.3A
5.0A
8.0A
12.0A
2.3A
5.0A
Catalog Number
22B-V2P3N104
22B-V5P0N104
22B-V6P0N104
22B-A2P3N114 B
22B-A5P0N114 B
B
B
Frame
Size
B
22B-A8P0N114
22B-A012N114
22B-A2P3N104 B
22B-A5P0N104 B
B
C
22B-A8P0N104
22B-A012N104
22B-B2P3N104
22B-B5P0N104
22B-B8P0N104
22B-B012N104
22B-B017N104
22B-B024N104
B
B
B
C
B
C
B
B
22B-B033N104
22B-D1P4N104
22B-D2P3N104
22B-D4P0N104
22B-D6P0N104
22B-D010N104
22B-D012N104
22B-D017N104
B
B
C
C
C
B
B
B
B-2
Accessories and Dimensions
Table B.C Dynamic Brake Modules
Drive Ratings
Input Voltage
120V 50/60 Hz
1-Phase
240V 50/60 Hz
1-Phase
240V 50/60 Hz
3-Phase
480V 50/60 Hz
3-Phase
7.5
0.4
0.75
1.5
1.5
2.2
3.7
5.5
2.2
4.0
5.5
7.5
1.5
2.2
0.4
0.75
kW
0.4
0.75
1.1
0.4
0.75
10.0
0.5
1.0
2.0
2.0
3.0
5.0
7.5
3.0
5.0
7.5
10.0
2.0
3.0
0.5
1.0
HP
0.5
1.0
1.5
0.5
1.0
10
–
97
97
48
32
19
13
97
77
55
39
48
32
–
48
Minimum
Resistance
Ω
–
48
48
–
48
AK-R2-360P500
AK-R2-360P500
AK-R2-120P1K2
AK-R2-120P1K2
AK-R2-120P1K2
AK-R2-120P1K2
Catalog Number
(1)
(2)
AK-R2-091P500
AK-R2-091P500
(2)
AK-R2-091P500
AK-R2-091P500
AK-R2-047P500
(2)
AK-R2-091P500
AK-R2-091P500
AK-R2-047P500
AK-R2-047P500
AK-R2-030P1K2
AK-R2-030P1K2
(2)
(1)
(2)
The resistors listed in this tables are rated for 5% duty cycle.
Drive does not support dynamic braking.
Table B.D Bulletin 1321-3R Series Line Reactors
Input Voltage kW HP
240V 50/60 Hz
3-Phase
0.4
0.75
0.5
1.0
4
8
Fundamental
Amps
1.5
2.0
8
2.2
3.0
12
3.7
5.0
18
5.5
7.5
25
480V 50/60 Hz
3-Phase
7.5
10.0
35
0.4
0.5
2
0.75
1.0
4
1.5
2.0
4
2.2
3.0
8
4.0
5.0
12
5.5
7.5
12
7.5
10.0
18
12
18
18
27
6
6
52.5
3
12
18
27
37.5
Maximum
Continuous
Amps Inductance
6
12
12.0 mh
3.0 mh
1.5 mh
1.25 mh
0.8 mh
0.5 mh
0.4 mh
20.0 mh
9.0 mh
6.5 mh
5.0 mh
2.5 mh
2.5 mh
1.5 mh
Watts
Loss
21 W
29 W
Catalog
Number
(1)
1321-3R4-D
1321-3R8-B
19.5 W 1321-3R8-A
26 W 1321-3R12-A
36 W
48 W
1321-3R18-A
1321-3R25-A
49 W 1321-3R35-A
11.3 W 1321-3R2-B
20 W
20 W
1321-3R4-C
1321-3R4-B
25.3 W 1321-3R8-C
31 W 1321-3R12-B
31 W
43 W
1321-3R12-B
1321-3R18-B
(1)
Catalog numbers listed are for 3% impedance open style units. NEMA Type 1 and 5% impedance reactor types are also available. Refer to publication 1321-TD001….
Accessories and Dimensions
B-3
Table B.E DC Bus Inductors
Input Voltage
240V 50/60 Hz
3-Phase
480V 50/60 Hz
3-Phase
kW
5.5
7.5
5.5
7.5
HP
7.5
10.0
7.5
10.0
Amps
32
40
18
25
Inductance
0.85 mh
0.5 mh
3.75 mh
4.0 mh
MTE Catalog Number
(1)
32RB001
40RB001
18RB004
25RB005
(1)
Use MTE RB Series or equivalent inductors.
Table B.F EMC Line Filters
Drive Ratings
Input Voltage
120V 50/60 Hz
1-Phase
240V 50/60 Hz
1-Phase
240V 50/60 Hz
3-Phase
480V 50/60 Hz
3-Phase
10.0
0.5
1.0
2.0
2.0
3.0
5.0
7.5
3.0
5.0
7.5
10.0
2.0
3.0
0.5
1.0
HP
0.5
1.0
1.5
0.5
1.0
7.5
0.4
0.75
1.5
1.5
2.2
3.7
5.5
2.2
4.0
5.5
7.5
1.5
2.2
0.4
0.75
kW
0.4
0.75
1.1
0.4
0.75
–
–
(2)
S Type Filter
Catalog Number
(1)
–
22-RF021-BS
(3)
22-RF021-BS
22-RF021-BS
22-RF021-BS
22-RF021-BS
22-RF034-CS
22-RF034-CS
22-RF012-BS
22-RF012-BS
22-RF012-BS
22-RF012-BS
22-RF012-BS
22-RF018-CS
22-RF018-CS
L Type Filter
Catalog Number
(4)
22-RF018-BL
22-RF018-BL
22-RF018-BL
22-RF018-BL
22-RF018-BL
22-RF018-BL
22-RF025-CL
22-RF021-BL
22-RF021-BL
22-RF021-BL
22-RF021-BL
22-RF021-BL
22-RF034-CL
22-RF034-CL
22-RF012-BL
22-RF012-BL
22-RF012-BL
22-RF012-BL
22-RF012-BL
22-RF018-CL
22-RF018-CL
(1)
(2)
(3)
(4)
This filter is suitable for use with a cable length of at least 10 meters (33 feet) for Class A and 1 meter for Class B environments.
These ratings can be ordered with internal “S Type” filters. Refer to the Catalog Number explanation on
and
Filter must be Series B or later.
This filter is suitable for use with a cable length of at least 100 meters for Class A and 5 meters for
Class B environments.
B-4
Accessories and Dimensions
Table B.G Human Interface Module (HIM) Option Kits and Accessories
Item
LCD Display, Remote Panel
Mount
Description
Digital speed control
CopyCat capable
IP66 (NEMA Type 4X/12) indoor use only
Includes 2.9 meter cable
LCD Display, Remote Handheld Digital speed control
Full numeric keypad
CopyCat capable
IP30 (NEMA Type 1)
Includes 1.0 meter cable
Panel mount with optional Bezel Kit
Bezel Kit
DSI HIM Cable
(DSI HIM to RJ45 cable)
Panel mount for LCD Display, Remote
Handheld unit, IP30 (NEMA Type 1)
1.0 Meter (3.3 Feet)
2.9 Meter (9.51 Feet)
Catalog Number
22-HIM-C2
22-HIM-A3
22-HIM-B1
22-HIM-H10
22-HIM-H30
Table B.H Communication Option Kits and Accessories
Item
DeviceNet
Communication Adapter
Communication Adapter
Cover
Description
Embedded communication option for use with the
PowerFlex family of drives.
Requires a Communication Adapter Cover (Ordered
Separately).
Cover that houses the DeviceNet Communication
Adapter.
B Frame Drive
C Frame Drive
Catalog Number
22-COMM-D
22B-CCB
22B-CCC
22-SCM-232 Serial Converter Module
(RS485 to RS232)
DSI Cable
Provides serial communication via DF1 protocol for use with DriveExplorer and DriveExecutive software.
Includes:
DSI to RS232 serial converter (1)
1203-SFC serial cable (1)
22-RJ45CBL-C20 cable (1)
DriveExplorer Lite CD (1)
2.0 meter RJ45 to RJ45 cable, male to male connectors.
22-RJ45CBL-C20
Serial Cable
Null Cable Converter
2.0 meter serial cable with a locking low profile connector to connect to the serial converter and a
9-pin sub-miniature D female connector to connect to a computer.
For use when connecting the serial converter to
DriveExplorer on a handheld PC.
Splitter Cable RJ45 one to two port splitter cable
Terminating Resistors RJ45 120 Ohm resistors (2 pieces)
1203-SFC
1203-SNM
AK-U0-RJ45-SC1
AK-U0-RJ45-TR1
Terminal Block
DriveExplorer Software
(CD-ROM) Version 3.01 or later
RJ45 Two position terminal block (5 pieces)
Windows based software package that provides an intuitive means for monitoring or configuring
Allen-Bradley drives and communication adapters online.
Compatibility:
Windows 95, 98, ME, NT 4.0 (Service Pack 3 or later), 2000, XP and CE
(1)
AK-U0-RJ45-TB2P
9306-4EXP01ENE
DriveExecutive software
(CD-ROM) Version 1.01 or later
Windows based software package that provides an intuitive means for monitoring or configuring
Allen-Bradley drives and communication adapters online and offline.
Compatibility:
Windows 98, ME, NT 4.0 (Service Pack 3 or later),
2000 and XP
9303-4DTE01ENE
(1)
See www.ab.com/drives/driveexplorer.htm for supported devices.
Accessories and Dimensions
B-5
Table B.I IP30/NEMA 1/UL Type 1 Kit
Item
IP30/NEMA 1/UL Type 1
Kit
Description
Field installed kit. Converts drive to IP30/
NEMA 1/UL Type 1 enclosure. Includes conduit box with mounting screws and plastic top panel.
IP30/NEMA 1/UL Type 1
Kit for Communication
Option
Field installed kit. Converts drive to IP30/
NEMA 1/UL Type 1 enclosure. Includes communication option conduit box with mounting screws and plastic top panel.
Drive
Frame Catalog Number
B 22-JBAB
C 22-JBAC
B 22-JBCB
C 22-JBCC
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 7 Who Should Use this Manual?
- 7 Reference Materials
- 8 Manual Conventions
- 8 Drive Frame Sizes
- 9 General Precautions
- 10 Catalog Number Explanation
- 11 Opening the Cover
- 12 Mounting Considerations
- 13 AC Supply Source Considerations
- 14 General Grounding Requirements
- 16 Fuses and Circuit Breakers
- 18 Power Wiring
- 22 I/O Wiring Recommendations
- 30 Start and Speed Reference Control
- 32 EMC Instructions
- 35 Prepare For Drive Start-Up
- 37 Integral Keypad
- 38 Viewing and Editing Parameters
- 39 About Parameters
- 40 Parameter Organization
- 41 Display Group
- 47 Basic Program Group
- 52 Advanced Program Group
- 79 Parameter Cross Reference – by Name
- 81 Drive Status
- 81 Faults
- 83 Fault Descriptions
- 85 Common Symptoms and Corrective Actions
- 89 Drive, Fuse & Circuit Breaker Ratings
- 90 Specifications
- 93 Product Selection
- 98 Product Dimensions
- 107 Network Wiring
- 108 Parameter Configuration
- 108 Supported Modbus Function Codes
- 109 Writing (06) Logic Command Data
- 109 Writing (06) Reference
- 110 Reading (03) Logic Status Data
- 110 Reading (03) Feedback
- 111 Reading (03) Drive Error Codes
- 111 Reading (03) and Writing (06) Drive Parameters
- 111 Additional Information
- 113 Connectivity Guidelines
- 114 DSI Cable Accessories
- 115 Connecting One Temporary Peripheral
- 115 Connecting One Temporary Peripheral and One Permanent Peripheral
- 116 Connecting Two Permanent Peripherals
- 116 Connecting an RS-485 Network
- 118 Step Logic Using Timed Steps
- 119 Step Logic Using Basic Logic Functions
- 120 Timer Function
- 122 Counter Function
- 125 PID Loop
- 128 PID Reference and Feedback
- 129 Analog PID Reference Signals