Legacy Platinum SCR Single Phase Charger

Add to my manuals
30 Pages

advertisement

Legacy Platinum SCR Single Phase Charger | Manualzz

STRT T ACT

STRT T ACT defines if a charge cycle will only start, if a valid battery is connected to the charger, after a specified time. If STRT T ACT is enabled, system setting STRT T defines the time at which a charge cycle will automatically start if a valid battery is connected.

Units Enabled/Disabled

STRT T

STRT T defines the time at which a charge cycle will automatically start when a valid battery is connected if

STRT T ACT is enabled.

Range 00:00-23:59

SULF MIN

SULF MIN defines the minimum duration of time that the charger will remain in start current regardless of battery voltage to break down sulfated batteries for WET type batteries only.

Units Minutes

Range 0-10

9.7 Battery Profile Settings

The charger was factory-configured with the Battery Profile Settings that were specified at the time of order.

STRT C

STRT C defines the start current.

Unit Amps

FIN C

FIN C defines the finish current.

Unit Amps

Range 0.1- 50% of STRT C

T PST KNEE

T PST KNEE defines the duration of time after the first knee (or 80% point) before the charge cycle is automatically terminated if Time Past Knee termination is enabled in the battery profile.

Unit Minutes

Range 30-600 www.douglasbattery.com 27 of 30 User’s Manual