PowerFlex 700 Technical Data

User Installed Options

Human Interface and Wireless Interface Modules

No HIM (Blank Plate)

20-HIM-A0

LCD Display, Full

Numeric Keypad

20-HIM-A3

LCD Display,

Programmer Only

20-HIM-A5

Wireless Interface

Module

20-WIM-N1

8

Remote (Panel Mount)

LCD Display, Full

Numeric Keypad

20-HIM-C3S

Remote (Panel Mount)

LCD Display,

Programmer Only

20-HIM-C5S

Description

No HIM (Blank Plate)

LCD Display, Full Numeric Keypad

LCD Display, Programmer Only

Wireless Interface Module

Handheld/Local

(Drive Mount)

Cat. No.

20-HIM-A0

20-HIM-A3

20-HIM-A5

20-WIM-N1

Remote (Panel

Mount) IP66,

NEMA/UL Type

4x/12

Cat. No.

20-HIM-C3S

20-HIM-C5S

20-WIM-N4S

For indoor use only.

‡ Includes a 1202-C30 interface cable (3 meters) for connection to drive.

Human Interface Module Accessories

Description

Bezel Kit for LCD HIMs, NEMA/UL Type 1 ‡

PowerFlex HIM Interface Cable, 1 m (39 in)

Cable Kit (Male-Female)

ä

0.33 Meters (1.1 Feet)

1 Meter (3.3 Feet)

3 Meter (9.8 Feet)

9 Meter (29.5 Feet)

DPI/SCANport™ One to Two Port Splitter Cable

Cat. No.

20-HIM-B1

20-HIM-H10

1202-H03

1202-H10

1202-H30

1202-H90

1203-S03

‡ Includes a 1202-C30 interface cable (3 meters) for connection to drive.

Required only when HIM is used as handheld or remote.

Required in addition to 20-HIM-H10 for distances up to a total maximum of 10 Meters (32.8 Feet).

Remote (Panel Mount)

Wireless Interface

Module

20-WIM-N4S

Control Cassette Option Kits

Control with I/O

Standard Control (Open Loop) - No I/O

Standard Control (Open Loop) - 24V DC/AC

Standard Control (Open Loop) - 115V AC

Vector Control (Series B) - 24V DC

Vector Control (Series B) - 24V DC with:

60 Hz Maximum

82 Hz Maximum

Cascading Fan/Pump Control

Pump Off (for Pump Jack)

Vector Control (Series B) - 24V DC, Conformal Coat

Vector Control (Series B) - 115V AC

Vector Control (Series B) - 115V AC with:

60 Hz Maximum

82 Hz Maximum

Cascading Fan/Pump Control

Pump Off (for Pump Jack)

Vector Control (Series B) - 115V AC, Conformal Coat

Cat. No.

20B-STD-N

20B-STD-A0

20B-STD-B0

20B-VECTB-C0

20B-VECT-C0AD

20B-VECTB-C0AX

20B-VECT-C0AE

20B-VECTB-C0BA

20B-VECTB-C0-

MX3

20B-VECTB-D0

20B-VECT-D0AD

20B-VECTB-D0AX

20B-VECT-D0AE

20B-VECT-D0BA

20B-VECTB-D0-

MX3

Vector Control option utilizes DPI Only.

Encoder Option Kit (Vector Control Only)

Description

12V/5V Encoder

12V/5V Encoder with Conformal Coat

Cat. No.

20B-ENC-1

20B-ENC-1-MX3

Terminal Block Replacement Kit

Description

Removable I/O Terminal Block

Removable Encoder Terminal Block

Cat. No.

SK-G9-TB1-S1

SK-G9-TB1-ENC1

I/O Option Kit (Standard Control Only)

24V DC/AC

115V AC

Description Cat. No.

20-DA1-A0

20-DA1-B0

20B-TD001F-EN-P

PowerFlex 700 Technical Data

Communication Option Kits

Description

BACnet ® MS/TP RS485 Communication Adapter

ControlNet™ Communication Adapter (Coax)

ControlNet™ Communication Adapter (Coax)

Conformal Coat

Cat. No.

20-COMM-B

20-COMM-C

20-COMM-C-MX3

DeviceNet™ Communication Adapter 20-COMM-D

DeviceNet™ Communication Adapter Conformal Coat 20-COMM-D-MX3

EtherNet/IP™ Communication Adapter 20-COMM-E

EtherNet/IP™ Communication Adapter Conformal Coat 20-COMM-E-MX3

HVAC Communication Adapter

Interbus™ Communication Adapter

CANopen ® Communication Adapter

LonWorks ® Communication Adapter

Modbus/TCP Communication Adapter

PROFIBUS™ DP Communication Adapter

ControlNet™ Communication Adapter (Fiber)

Remote I/O Communication Adapter

Remote I/O Communication Adapter Conformal Coat

RS485 DF1 Communication Adapter

RS485 DF1 Communication Adapter Conformal Coat

External Communications Kit Power Supply

DPI External Communications Kit

External DPI I/O Option Board

Compact I/O Module (3 Channel)

Serial Null Modem Adapter

Smart Self-powered Serial Converter (RS232) includes

1203-SFC and 1202-C10 Cables

Universal Serial Bus™ (USB) Converter includes 2m

USB, 20-HIM-H10 & 22-HIM-H10 Cables

20-COMM-H

20-COMM-I

20-COMM-K

20-COMM-L

20-COMM-M

20-COMM-P

20-COMM-Q

20-COMM-R

20-COMM-R-MX3

20-COMM-S

20-COMM-S-MX3

20-XCOMM-AC-

PS1

20-XCOMM-DC-

BASE

20-XCOMM-IO-

OPT1

1769-SM1

1203-SNM

1203-SSS

1203-USB

‡ For use only with DPI External Communications Kits 20-XCOMM-DC-

BASE.

Only Modbus RTU can be used with Vector Control.

Can only be used with Standard Control.

Internal Dynamic Brake Resistor Kits

These resistors have a limited duty cycle. Refer to the PowerFlex

Dynamic Braking Selection Guide to determine if an internal resistor will be sufficient for your application. An external resistor may be required.

Drive Input

Voltage

208…240V AC

380…600V AC

380…480V AC

Brake Resistance

Ω

62

62

22

22

115

115

68

§ Discount Schedule C2.

Frame

0

1 (2…5 Hp)

1 (7.5 Hp)

2

0

1

2

Cat. No.

20BB-DB1-0

20BB-DB1-1

20BB-DB2-1

20BB-DB1-2

20BD-DB1-0

20BD-DB1-1

20BD-DB1-2

Terminators

Description for use with 3.7 kW (5 Hp) & below drives for use with 1.5 kW (2 Hp) & up drives

Cat. No.

1204-TFA1

1204-TFB2

See Appendix A of publication DRIVES-IN001 for selection information.

Dynamic Brake, Chopper Only Kits

Description

200…240V AC

380…480V AC

500…600V AC

Rating

18A

70A

115A

9A

35A

110A

9A

35A

85A

Cat. No.

1336-WA018

1336-WA070

1336-WA115

1336-WB009

1336-WB035

1336-WB110

1336-WC009

1336-WC035

1336-WC085

PC Programming Software

Description

DriveTools™ SP Software

DriveExplorer™ Software (Lite/Full)

See publication 9303-PL002… for ordering/pricing information.

Set-up wizards are available for use with DriveTools SP and DriveExplorer

(Lite/Full) only.

DriveExplorer Lite is available for free download at: http://www.ab.com/drives/driveexplorer/free_download.html

.

Reflected Wave Reduction Modules w/CM Choke

Description

17A with Common Mode Choke

Cat. No.

1204-RWC-17-A

See Appendix A of publication DRIVES-IN001 for selection information.

Reflected Wave Reduction Modules

Voltage

480V AC

600V AC

40.0

50.0

60.0

75.0

100.0

125.0

150.0

200.0

250.0

5.0

7.5

5.0

7.5

10.0

15.0

20.0

25.0

30.0

ND Hp

10.0

15.0

20.0

25.0

30.0

40.0

50.0

60.0

75.0

100.0

125.0

150.0

20BE011

20BE017

20BE022

20BE027

20BE032

20BE041

20BE052

20BE062

20BE077

20BE099

20BE125

20BE144

Drive Cat. No.

20BD8P0

20BD011

20BD014

20BD022

20BD027

20BD034

20BD040

20BD052

20BD065

20BD077

20BD096

20BD125

20BD156

20BD180

20BD248

20BD292

20BE6P1

20BE9P0

Cat. No.

1321-RWR8-DP

1321-RWR12-DP

1321-RWR18-DP

1321-RWR25-DP

1321-RWR35-DP

1321-RWR35-DP

1321-RWR45-DP

1321-RWR55-DP

1321-RWR80-DP

1321-RWR80-DP

1321-RWR100-DP

1321-RWR130-DP

1321-RWR160-DP

1321-RWR200-DP

1321-RWR250-DP

1321-RWR320-DP

1321-RWR8-EP

1321-RWR12-EP

1321-RWR12-EP

1321-RWR18-EP

1321-RWR25-EP

1321-RWR35-EP

1321-RWR35-EP

1321-RWR45-EP

1321-RWR55-EP

1321-RWR80-EP

1321-RWR80-EP

1321-RWR100-EP

1321-RWR130-EP

1321-RWR160-EP

20B-TD001F-EN-P

9

PowerFlex 700 Technical Data

Isolation Transformers

For installations that have specific types of AC supply configurations or require drive protection due to AC line disturbances, isolation transformers are available.

Motor Rating kW (Hp)

IP32 (NEMA/UL Type 3R)

240V, 60 Hz, Three-Phase,

240V Primary & 240V Secondary

460V, 60 Hz, Three-Phase,

460V Primary & 460V Secondary

575V, 60 Hz, Three-Phase,

575V Primary & 575V Secondary

1.1 1321-3TW005-AA 1321-3TW005-BB –

1.5 1321-3TW005-AA 1321-3TW005-BB 1321-3TW005-CC

2.2 1321-3TW005-AA 1321-3TW005-BB 1321-3TW005-CC

4.0 1321-3TW007-AA 1321-3TW007-BB 1321-3TW007-CC

5.5 1321-3TW011-AA 1321-3TW011-BB 1321-3TW011-CC

7.5 1321-3TW014-AA 1321-3TW014-BB 1321-3TW014-CC

37 1321-3TH063-AA 1321-3TH063-BB 1321-3TH063-CC

45 1321-3TH075-AA 1321-3TH075-BB 1321-3TH075-CC

55 1321-3TH093-AA 1321-3TH093-BB 1321-3TH093-CC

75 (100) – 1321-3TH118-BB 1321-3TH118-CC

90 (125)

110 (150)

149 (200)

187 (250)

1321-3TH145-BB 1321-3TH145-CC

1321-3TH175-BB 1321-3TH175-CC

1321-3TH220-BB

1321-3TH275-BB

1321-3TH220-CC

1321-3TH275-CC

224 (300)

261 (350)

298 (400)

336 (450)

373 (500)

448 (600)

485 (650)

522 (700)

1321-3TH330-BB

1321-3TH440-BB

1321-3TH440-BB

1321-3TH550-BB

1321-3TH550-BB

1321-3TH660-BB

1321-3TH770-BB

1321-3TH330-CC

1321-3TH440-CC

1321-3TH440-CC

1321-3TH550-CC

1321-3TH550-CC

1321-3TH660-CC

1321-3TH770-CC

1321-3TH770-CC

10

20B-TD001F-EN-P

PowerFlex 700 Technical Data

Input/Output Line Reactors

For impedance matching, protection from AC line disturbances or motor protection, reactors are available for both the input and output sides of the drive.

240V, 60 Hz, Three-Phase, 3% Impedance

Input Line Reactor

(1)

IP00 (Open Style)

Drive Cat. No. Duty Hp

Output Line Reactor

(1)

IP11 (NEMA/UL Type 1) IP00 (Open Style) IP11 (NEMA/UL Type 1)

1321-3RA8-A 1321-3R12-A 1321-3RA12-A

Heavy 40

Heavy 50

20BB260

Heavy 60

Duty 1321-3RA200-A 1321-3R200-A

Heavy 1321-3R200-A 1321-3RA200-A

100

1321-3RA200-A

(1) Input line reactors were sized based on the NEC fundamental motor amps. Output line reactors were sized based on the VFD rated output currents.

20B-TD001F-EN-P

11

PowerFlex 700 Technical Data

240V, 60 Hz, Three-Phase, 5% Impedance

Drive Cat. No. Duty Hp

Input Line Reactor

(1)

IP00 (Open Style)

Cat. No.

Output Line Reactor

(1)

IP11 (NEMA/UL Type 1) IP00 (Open Style)

Cat. No. Cat. No.

IP11 (NEMA/UL Type 1)

Cat. No.

1321-3RA8-B 1321-3R12-B 1321-3RA12-B

Heavy 40

Heavy 50

20BB260

Heavy 60

Duty 1321-3RA200-B 1321-3R200-B

Heavy 1321-3R200-B 1321-3RA200-B

100

1321-3RA200-B

(1) Input line reactors were sized based on the NEC fundamental motor amps. Output line reactors were sized based on the VFD rated output currents.

12

20B-TD001F-EN-P

PowerFlex 700 Technical Data

480V, 60 Hz, Three-Phase, 3% Impedance

Drive Cat. No. Duty

Input Line Reactor

(1)

IP00 (Open Style) IP11 (NEMA/UL Type 1)

Output Line Reactor

IP00 (Open Style)

(1)

IP11 (NEMA/UL Type 1)

Hp

Cat. No. Cat. No. Cat. No. Cat. No.

0.33 1321-3RA1-C 1321-3R2-B 1321-3RA2-B

0.5 1321-3RA1-C 1321-3R2-B 1321-3RA2-B

1.5 1321-3RA4-C 1321-3R4-B 1321-3RA4-B

2 1321-3RA4-B 1321-3R8-C 1321-3RA8-C

3 1321-3RA8-C 1321-3R8-B 1321-3RA8-B

5 1321-3RA8-B 1321-3R12-B 1321-3RA12-B

1321-3RA100-B

20BD600 Normal Duty 500 1321-3R600-B 1321-3RA600-B 1321-3R600-B 1321-3RA600-B

20BD875 Normal Duty 700 1321-3R850-B 1321-3RA850-B 1321-3R850-B 1321-3RA850-B

(1) Input line reactors were sized based on the NEC fundamental motor amps. Output line reactors were sized based on the VFD rated output currents.

20B-TD001F-EN-P

13

PowerFlex 700 Technical Data

480V, 60 Hz, Three-Phase, 5% Impedance

Drive Cat. No. Duty

Input Line Reactor

(1)

IP00 (Open Style) IP11 (NEMA/UL Type 1)

Output Line Reactor

IP00 (Open Style)

(1)

IP11 (NEMA/UL Type 1)

Hp

Cat. No. Cat. No. Cat. No. Cat. No.

0.33 1321-3RA1-B 1321-3R2-C 1321-3RA2-C

0.5 1321-3RA1-B 1321-3R2-C 1321-3RA2-C

0.75 1321-3RA2-C 1321-3R2-B 1321-3RA2-B

20BD248

5 1321-3RA8-C 1321-3R12-C 1321-3RA12-C

Duty 1321-3R18-C 1321-3RA18-C

Duty 1321-3R25-C 1321-3RA25-C

Duty 1321-3R25-C 1321-3RA25-C

20

20

(2)

(2)

1321-3RA35-C (2)

1321-3RA35-C

(2)

1321-3R25-C 1321-3RA25-C

1321-3R35-C 1321-3RA35-C

Duty 1321-3R45-C 1321-3RA45-C

Duty 1321-3R55-C 1321-3RA55-C

Duty 1321-3R80-C 1321-3RA80-C

Duty 1321-3R80-C 1321-3RA80-C

Duty 1321-3R80-C 1321-3RA80-C

1321-3RA100-C

Duty 1321-3R130-C 1321-3RA130-C

Duty 1321-3R160-C 1321-3RA160-C

150

(2)

150 (2)

Normal Duty 200 1321-3RB250-C 1321-3RAB250-C 1321-3RB250-C

1321-3RA200-C

(2)

1321-3RA200-C (2)

1321-3RAB250-C

Duty 1321-3R500-C 1321-3RA500-C

Duty 1321-3R500-C 1321-3RA500-C

Duty 1321-3R600-C 1321-3RA600-C

Duty 1321-3R750-E 1321-3RA750-E

20BD875

(1)

(2)

Normal Duty 700 1321-3R850-C 1321-3RA850-C 1321-3R850-C

Input line reactors were sized based on the NEC fundamental motor amps. Output line reactors were sized based on the VFD rated output currents.

4% impedance.

1321-3RA850-C

14

20B-TD001F-EN-P

PowerFlex 700 Technical Data

600V, 60 Hz, Three-Phase, 3% Impedance

Drive Cat. No. Duty

Input Line Reactor

(1)

IP00 (Open Style) IP11 (NEMA/UL Type 1)

Output Line Reactor

IP00 (Open Style)

(1)

IP11 (NEMA/UL Type 1)

Hp

Cat. No. Cat. No. Cat. No. Cat. No.

0.5 1321-3RA1-C 1321-3R2-B 1321-3RA2-B

1 1321-3RA2-B 1321-3R2-B 1321-3RA2-B

1 1321-3RA2-B 1321-3R4-D 1321-3RA4-D

2 1321-3RA4-D 1321-3R4-D 1321-3RA4-D

2 1321-3RA4-D 1321-3R4-C 1321-3RA4-C

3 1321-3RA4-C 1321-3R4-C 1321-3RA4-C

3 1321-3RA4-C 1321-3R8-C 1321-3RA8-C

5 1321-3RA8-C 1321-3R8-C 1321-3RA8-C

5 1321-3RA8-C 1321-3R12-C 1321-3RA12-C

Duty 1321-3R18-B 1321-3RA18-B

Duty 1321-3R25-B 1321-3RA25-B

Duty 1321-3R45-B 1321-3RA45-B

Duty 1321-3R55-B 1321-3RA55-B

Duty 1321-3R80-B 1321-3RA80-B

Duty 1321-3R80-B 1321-3RA80-B

Duty 1321-3R80-B 1321-3RA80-B

Duty 1321-3R100-B 1321-3RA100-B 1321-3R100-B 1321-3RA100-B

Duty 1321-3R130-B 1321-3RA130-B

20BE144 Normal Duty 150 1321-3R160-B 1321-3RA160-B 1321-3R160-B

(1) Input line reactors were sized based on the NEC fundamental motor amps. Output line reactors were sized based on the VFD rated output currents.

1321-3RA160-B

20B-TD001F-EN-P

15

PowerFlex 700 Technical Data

600V, 60 Hz, Three-Phase, 5% Impedance

Drive Cat. No. Duty

Input Line Reactor

(1)

IP00 (Open Style) IP11 (NEMA/UL Type 1)

Output Line Reactor

IP00 (Open Style)

(1)

IP11 (NEMA/UL Type 1)

Hp

Cat. No. Cat. No. Cat. No. Cat. No.

0.5 1321-3RA1-B 1321-3R2-C 1321-3RA2-C

1

2

2

(2)

(2)

1321-3RA2-C 1321-3R4-D

1321-3RA4-D

1321-3RA4-D

(2)

(2)

(2)

1321-3R4-D

(2)

1321-3RA4-D

(2)

1321-3RA4-D

(2)

1321-3R4-D 1321-3RA4-D

5

7.5

7.5

(2)

(2)

1321-3RA8-D 1321-3R12-C

1321-3RA12-C (2)

1321-3RA12-C

(2)

(2) 1321-3RA12-C (2)

1321-3R12-C (2) 1321-3RA12-C (2)

1321-3R12-C 1321-3RA12-C

Duty 1321-3R18-C 1321-3RA18-C

15

(2)

20

(2)

20 (2)

1321-3RA25-C

(2)

1321-3RA25-C (2)

1321-3R25-C

1321-3R35-C

(2)

(2)

25

25

30

30

(2)

(2)

(2)

(2)

1321-3RA35-C

1321-3RA35-C

1321-3RA35-C

1321-3RA35-C

(2)

(2)

(2)

(2)

1321-3RA25-C

(2)

1321-3RA25-C

(2)

1321-3RA35-C (2)

1321-3R35-C (2)

1321-3R35-C

(2)

1321-3RA35-C (2)

1321-3RA35-C

(2)

1321-3R35-C

(2)

1321-3RA35-C

(2)

1321-3R45-C 1321-3RA45-C

Duty 1321-3R55-C 1321-3RA55-C

Duty 1321-3R80-C 1321-3RA80-C

Duty 1321-3R80-C 1321-3RA80-C

Duty 1321-3R80-C 1321-3RA80-C

Duty 1321-3R100-C 1321-3RA100-C 1321-3R100-C 1321-3RA100-C

20BE144

125

(2)

125 (2)

Normal Duty 150 1321-3R160-C (2)

1321-3RA130-C

(2)

1321-3RA130-C (2)

1321-3RA160-C (2)

1321-3R130-C

(2)

1321-3R130-C (2)

1321-3R160-C (2)

(1)

(2)

Input line reactors were sized based on the NEC fundamental motor amps. Output line reactors were sized based on the VFD rated output currents.

4% impedance.

1321-3RA130-C

(2)

1321-3RA130-C (2)

1321-3RA160-C (2)

16

20B-TD001F-EN-P

advertisement