Setting Datums using NOTE/SET Function
The NOTE/SET function is useful for setting a datum when a tool is under load, and the diameter of the workpiece is not known.
To use the NOTE/SET function:
Press the DATUM hard key.
The cursor will be in the Datum Number field.
Enter the datum number, and press the DOWN
ARROW key to go to the X AXIS field.
Turn a diameter in the X axis.
Press the NOTE soft key while the tool is still cutting.
Retract from the current position.
Turn the spindle off, and measure the workpiece diameter.
Enter the measured diameter, for example, 15 mm, and press Enter.
Remember to ensure the ND 522/523 is in diameter display mode (Ø) to input a diameter value.
ND 522/523
63
advertisement
Related manuals
Download
PDF
advertisement
Table of contents
- 12 Datums
- 12 Actual Position, Nominal Position, and Distance- To-Go
- 13 Absolute Workpiece Positions
- 13 Incremental Workpiece Positions
- 14 Zero Angle Reference Axis
- 14 Position Encoders
- 15 Encoder Reference Marks
- 16 Screen Layout
- 17 General Operation Hard Key Function Overview
- 18 General Navigation
- 18 Operating Modes
- 20 Data Input Forms
- 20 Error Messages
- 21 Power Up
- 21 Reference Mark Evaluation
- 23 Setup
- 23 Job Setup Parameters
- 26 Import/Export
- 27 DRO Operating Screen Soft Key Function Overview
- 28 General Operation Key Functions Detailed
- 31 Key Functions Detailed
- 58 Keys Functions Detailed
- 59 Tool Table Usage
- 59 Setting tool offsets using TOOL/SET
- 60 Setting Tool Offset using NOTE/SET Function
- 61 Datum Hard key
- 63 Setting Datums using NOTE/SET Function
- 64 Taper Calculator Hard Key
- 65 Presetting
- 65 RX (Radius/Diameter) Soft Key
- 66 Vectoring Hard Key
- 67 Z Coupling (turning applications only)
- 67 Enabling Z Coupling
- 67 Disabling Z Coupling
- 70 Items Supplied
- 70 ND 522/523 Display Unit
- 70 Installation
- 73 Installation Setup Parameters
- 73 Encoder Setup
- 74 Display Configuration
- 74 Error Compensation
- 77 Backlash Compensation
- 78 Counter Settings
- 78 Diagnostics
- 84 Examples of character output at the data interface
- 89 Accessory ID Numbers