Figure 5-35 SEQUENCE RUN MODE: Failure Message. Wayne Kerr 3260B

Figure 5-35 SEQUENCE RUN MODE: Failure Message. Wayne Kerr 3260B

Add to My manuals
225 Pages

The Wayne Kerr 3260B is a Precision Magnetics Analyzer that allows for the 2-terminal and 4-terminal (Kelvin) measurement of inductors and transformers. It also offers DC resistance measurement capabilities. The frequency range for the device spans 20Hz to 3MHz, and the drive level can be adjusted between 1mV and 10V rms. The analyzer supports ALC to maintain drive level at the component. In addition, the 3260B has a DC bias current adjustable between 1mA and 1A and provides the option to use external 3265B DC Bias Units to achieve up to 125A DC bias current.

advertisement

Figure 5-35 SEQUENCE RUN MODE: Failure Message. Wayne Kerr 3260B | Manualzz

5–32

Advanced Operation

Figure 5-35 SEQUENCE RUN MODE: Failure Message

Selecting the Stop Running PROGRAM No. X soft key will allow a new sequence program to be selected

5.12 HANDLER MODE

In HANDLER MODE the front panel connections are reconfigured to make the analyzer compatible with many existing 4-terminal fixtures and scanners (see Figure 5-3 for the connection protocol for HANDLER MODE). The screen layout is similar to IMPEDANCE

MODE but with the ability to measure turns ratio. The bar graph analogue scale is not available in HANDLER MODE.

5.12.1 Use of HANDLER MODE

1) Before any measurements are made using HANDLER MODE calibration MUST be carried, see section 4.6—Handler Calibration for information and methods of handler calibration.

2) Rdc and AC measurements are performed in the same way as IMPEDANCE MODE.

See section 4.7—Measuring a Component in IMPEDANCE MODE

3) Turns ratio measurements are performed in the same way as TRANSFORMER MODE.

See section 5.7. Turns ratio measurements in HANDLER MODE are made under 2terminal operation so the effects of measurement lead impedance and transformer shunt impedance cannot be avoided.

5.13 TELECOMS MODE

TELECOMS MODE allows line-matching-transformer insertion loss and return loss to be derived. The user may specify values of source impedance and terminating resistance. A damped network may also be selected with user-specified values and, if required, a DC blocking capacitor in the source line. The pictures below show the three configurations with default component values.

advertisement

Key Features

  • 2/4 terminal measurement
  • Frequency range: 20Hz to 3MHz
  • DC bias current up to 125A
  • Automatic level control (ALC)
  • Telecom function
  • In-circuit measurements
  • Measurement of very small capacitors/inductors
  • Measurement of iron-cored/ferrite inductors
  • Measurement of transformers
  • BINNING MODE

Frequently Answers and Questions

What is the frequency range of the 3260B?
The frequency range of the 3260B is 20Hz to 3MHz.
What types of components can be measured with the 3260B?
The 3260B can measure inductors and transformers using 2-terminal or 4-terminal (Kelvin) connections.
What is the maximum DC bias current that can be supplied by the 3260B?
The 3260B can provide up to 125A DC bias current when using an external 3265B DC Bias Unit.
What are some of the advanced measurement modes available on the 3260B?
The 3260B offers advanced measurement modes such as BINNING MODE, SEQUENCE MODE, MULTI FREQ MODE, GRAPH MODE, RESONANCE MODE, and DEMAG MODE.
What is the purpose of the Telecom function on the 3260B?
The Telecom function allows for the measurement of insertion loss and return loss of line matching transformers, along with the ability to select damped network components and a blocking capacitor, if needed.